Use of population input functions for reduced scan duration whole-body Patlak 18F-FDG PET imaging

被引:18
|
作者
van Sluis, Joyce [1 ]
Yaqub, Maqsood [2 ]
Brouwers, Adrienne H. [1 ]
Dierckx, Rudi A. J. O. [1 ]
Noordzij, Walter [1 ]
Boellaard, Ronald [1 ,2 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Nucl Med & Mol Imaging, Hanzeplein 1, NL-9713 GZ Groningen, Netherlands
[2] Vrije Univ Amsterdam, Canc Ctr Amsterdam, Amsterdam UMC, Dept Radiol & Nucl Med, Amsterdam, Netherlands
关键词
Patlak; PET; CT; Dynamic imaging; Population input function; Scan time; CELL LUNG-CANCER; FDG-PET; THERAPY; RECOMMENDATIONS; QUANTIFICATION; REPEATABILITY; ANATOMY; TUMORS;
D O I
10.1186/s40658-021-00357-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Whole-body Patlak images can be obtained from an acquisition of first 6 min of dynamic imaging over the heart to obtain the arterial input function (IF), followed by multiple whole-body sweeps up to 60 min pi. The use of a population-averaged IF (PIF) could exclude the first dynamic scan and minimize whole-body sweeps to 30-60 min pi. Here, the effects of (incorrect) PIFs on the accuracy of the proposed Patlak method were assessed. In addition, the extent of mitigating these biases through rescaling of the PIF to image-derived IF values at 30-60 min pi was evaluated. Methods Using a representative IF and rate constants from the literature, various tumour time-activity curves (TACs) were simulated. Variations included multiplication of the IF with a positive and negative gradual linear bias over 60 min of 5, 10, 15, 20, and 25% (generating TACs using an IF different from the PIF); use of rate constants (K-1, k(3), and both K-1 and k(2)) multiplied by 2, 1.5, and 0.75; and addition of noise (mu = 0 and sigma = 5, 10 and 15%). Subsequent Patlak analysis using the original IF (representing the PIF) was used to obtain the influx constant (K-i) for the differently simulated TACs. Next, the PIF was scaled towards the (simulated) IF value using the 30-60-min pi time interval, simulating scaling of the PIF to image-derived values. Influence of variabilities in IF and rate constants, and rescaling the PIF on bias in K-i was evaluated. Results Percentage bias in K-i observed using simulated modified IFs varied from - 16 to 16% depending on the simulated amplitude and direction of the IF modifications. Subsequent scaling of the PIF reduced these K-i biases in most cases (287 out of 290) to < 5%. Conclusions Simulations suggest that scaling of a (possibly incorrect) PIF to IF values seen in whole-body dynamic imaging from 30 to 60 min pi can provide accurate Ki estimates. Consequently, dynamic Patlak imaging protocols may be performed for 30-60 min pi making whole-body Patlak imaging clinically feasible.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Whole-body 18F-FDG PET/CT in the presence of truncation artifacts
    Beyer, T
    Bockisch, A
    Kühl, H
    Martinez, MJ
    JOURNAL OF NUCLEAR MEDICINE, 2006, 47 (01) : 91 - 99
  • [22] Whole-body 18F-FDG PET in recurrent or metastatic nasopharyngeal carcinoma
    Yen, RF
    Hong, RL
    Tzen, KY
    Pan, MH
    Chen, THH
    JOURNAL OF NUCLEAR MEDICINE, 2005, 46 (05) : 770 - 774
  • [23] Autoimmune pancreatitis: whole-body 18F-FDG PET/CT findings
    Zhang, Jian
    Shao, Chengwei
    Wang, Jianhua
    Cheng, Chao
    Zuo, Changjing
    Sun, Gaofeng
    Cui, Bin
    Dong, Aisheng
    Liu, Qinghua
    Kong, Lingshan
    ABDOMINAL IMAGING, 2013, 38 (03): : 543 - 549
  • [24] Whole-Body 18F-FDG PET-CT in the Diagnosis of Neurosarcoidosis
    Fritz, Daan
    van de Beek, Diederik
    Brouwer, Matthijs C.
    Booij, Jan
    MAYO CLINIC PROCEEDINGS, 2020, 95 (05) : 1082 - 1084
  • [25] Clinical validation of a population-based input function for 20-min dynamic whole-body 18F-FDG multiparametric PET imaging
    Dias, Andre H.
    Smith, Anne M.
    Shah, Vijay
    Pigg, David
    Gormsen, Lars C.
    Munk, Ole L.
    EJNMMI PHYSICS, 2022, 9 (01)
  • [26] Clinical validation of a population-based input function for dynamic whole-body 18F-FDG multiparametric PET imaging using a standard injector
    Dias, A. H.
    Pigg, D.
    Smith, A. M.
    Shah, V.
    Gormsen, L. C.
    Munk, O. L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (SUPPL 1) : S198 - S199
  • [27] Clinical validation of a population-based input function for 20-min dynamic whole-body 18F-FDG multiparametric PET imaging
    André H. Dias
    Anne M. Smith
    Vijay Shah
    David Pigg
    Lars C. Gormsen
    Ole L. Munk
    EJNMMI Physics, 9
  • [28] 18F-FDG PET/CT and Whole-Body Bone Scan Findings in Gorlin-Goltz Syndrome
    Cheon, Miju
    Yoo, Jang
    Kang, Kyu-Bok
    DIAGNOSTICS, 2023, 13 (13)
  • [29] 18F-FDG PET/CT of Patients With Cancer: Comparison of Whole-Body and Limited Whole-Body Technique
    Osman, Medhat M.
    Chaar, Bassem T.
    Muzaffar, Razi
    Oliver, Dana
    Reimers, Hans Joachim
    Walz, Bruce
    Nguyen, Nghi C.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (06) : 1397 - 1403
  • [30] Combined early dynamic 18F-FDG PET/CT and conventional whole-body 18F-FDG PET/CT in hepatocellular carcinoma
    Zhang, Yiqiu
    Dong, Yun
    Yu, Wenjun
    Chen, Shuguang
    Yu, Haojun
    Li, Beilei
    Shi, Hongcheng
    ABDOMINAL RADIOLOGY, 2023, 48 (10) : 3127 - 3134