Use of population input functions for reduced scan duration whole-body Patlak 18F-FDG PET imaging

被引:18
|
作者
van Sluis, Joyce [1 ]
Yaqub, Maqsood [2 ]
Brouwers, Adrienne H. [1 ]
Dierckx, Rudi A. J. O. [1 ]
Noordzij, Walter [1 ]
Boellaard, Ronald [1 ,2 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Nucl Med & Mol Imaging, Hanzeplein 1, NL-9713 GZ Groningen, Netherlands
[2] Vrije Univ Amsterdam, Canc Ctr Amsterdam, Amsterdam UMC, Dept Radiol & Nucl Med, Amsterdam, Netherlands
关键词
Patlak; PET; CT; Dynamic imaging; Population input function; Scan time; CELL LUNG-CANCER; FDG-PET; THERAPY; RECOMMENDATIONS; QUANTIFICATION; REPEATABILITY; ANATOMY; TUMORS;
D O I
10.1186/s40658-021-00357-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Whole-body Patlak images can be obtained from an acquisition of first 6 min of dynamic imaging over the heart to obtain the arterial input function (IF), followed by multiple whole-body sweeps up to 60 min pi. The use of a population-averaged IF (PIF) could exclude the first dynamic scan and minimize whole-body sweeps to 30-60 min pi. Here, the effects of (incorrect) PIFs on the accuracy of the proposed Patlak method were assessed. In addition, the extent of mitigating these biases through rescaling of the PIF to image-derived IF values at 30-60 min pi was evaluated. Methods Using a representative IF and rate constants from the literature, various tumour time-activity curves (TACs) were simulated. Variations included multiplication of the IF with a positive and negative gradual linear bias over 60 min of 5, 10, 15, 20, and 25% (generating TACs using an IF different from the PIF); use of rate constants (K-1, k(3), and both K-1 and k(2)) multiplied by 2, 1.5, and 0.75; and addition of noise (mu = 0 and sigma = 5, 10 and 15%). Subsequent Patlak analysis using the original IF (representing the PIF) was used to obtain the influx constant (K-i) for the differently simulated TACs. Next, the PIF was scaled towards the (simulated) IF value using the 30-60-min pi time interval, simulating scaling of the PIF to image-derived values. Influence of variabilities in IF and rate constants, and rescaling the PIF on bias in K-i was evaluated. Results Percentage bias in K-i observed using simulated modified IFs varied from - 16 to 16% depending on the simulated amplitude and direction of the IF modifications. Subsequent scaling of the PIF reduced these K-i biases in most cases (287 out of 290) to < 5%. Conclusions Simulations suggest that scaling of a (possibly incorrect) PIF to IF values seen in whole-body dynamic imaging from 30 to 60 min pi can provide accurate Ki estimates. Consequently, dynamic Patlak imaging protocols may be performed for 30-60 min pi making whole-body Patlak imaging clinically feasible.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Use of population input functions for reduced scan duration whole-body Patlak 18F-FDG PET imaging
    Joyce van Sluis
    Maqsood Yaqub
    Adrienne H. Brouwers
    Rudi A. J. O. Dierckx
    Walter Noordzij
    Ronald Boellaard
    EJNMMI Physics, 8
  • [2] Use of population input functions for FDG whole-body Patlak imaging
    van Sluis, J.
    Yaqub, M.
    Brouwers, A. H.
    Noordzij, W.
    Boellaard, R.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (SUPPL 1) : S120 - S120
  • [3] Assessment of population-based input functions for Patlak imaging of whole body dynamic 18F-FDG PET
    Naganawa, Mika
    Gallezot, Jean-Dominique
    Shah, Vijay
    Mulnix, Tim
    Young, Colin
    Dias, Mark
    Chen, Ming-Kai
    Smith, Anne M.
    Carson, Richard E.
    EJNMMI PHYSICS, 2020, 7 (01)
  • [4] Assessment of population-based input functions for Patlak imaging of whole body dynamic 18F-FDG PET
    Mika Naganawa
    Jean-Dominique Gallezot
    Vijay Shah
    Tim Mulnix
    Colin Young
    Mark Dias
    Ming-Kai Chen
    Anne M. Smith
    Richard E. Carson
    EJNMMI Physics, 7
  • [5] Assessment of population-based input functions for the Patlak plot using whole body 18F-FDG PET imaging
    Naganawa, Mika
    Gallezot, Jean-Dominique
    Shah, Vijay
    Mulnix, Tim
    Chen, Ming-Kai
    Smith, Anne
    Carson, Richard
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60
  • [6] Whole-Body 18F-FDG PET/CT Patlak Parametric Imaging of Hepatic Alveolar Echinococcosis
    Maurer, Alexander
    Kotasidis, Fotis
    Deibel, Ansgar
    Burger, Irene A.
    Huellner, Martin W.
    CLINICAL NUCLEAR MEDICINE, 2023, 48 (12) : 1089 - 1090
  • [7] Shortened duration whole body 18F-FDG PET Patlak imaging on the Biograph Vision Quadra PET/CT using a population-averaged input function
    Joyce van Sluis
    Johannes H. van Snick
    Adrienne H. Brouwers
    Walter Noordzij
    Rudi A. J. O. Dierckx
    Ronald J. H. Borra
    Adriaan A. Lammertsma
    Andor W. J. M. Glaudemans
    Riemer H. J. A. Slart
    Maqsood Yaqub
    Charalampos Tsoumpas
    Ronald Boellaard
    EJNMMI Physics, 9
  • [8] Shortened duration whole body 18F-FDG PET Patlak imaging on the Biograph Vision Quadra PET/CT using a population-averaged input function
    van Sluis, Joyce
    van Snick, Johannes H.
    Brouwers, Adrienne H.
    Noordzij, Walter
    Dierckx, Rudi A. J. O.
    Borra, Ronald J. H.
    Lammertsma, Adriaan A.
    Glaudemans, Andor W. J. M.
    Slart, Riemer H. J. A.
    Yaqub, Maqsood
    Tsoumpas, Charalampos
    Boellaard, Ronald
    EJNMMI PHYSICS, 2022, 9 (01)
  • [9] Does whole-body Patlak 18F-FDG PET imaging improve lesion detectability in clinical oncology?
    Guillaume Fahrni
    Nicolas A. Karakatsanis
    Giulia Di Domenicantonio
    Valentina Garibotto
    Habib Zaidi
    European Radiology, 2019, 29 : 4812 - 4821
  • [10] Does whole-body Patlak 18F-FDG PET imaging improve lesion detectability in clinical oncology?
    Fahrni, Guillaume
    Karakatsanis, Nicolas A.
    Di Domenicantonio, Giulia
    Garibotto, Valentina
    Zaidi, Habib
    EUROPEAN RADIOLOGY, 2019, 29 (09) : 4812 - 4821