Numerical evaluation of the thermal performance of a near-surface earth-to-air heat exchanger with short-grass ground cover: A parametric study

被引:10
|
作者
Pakari, Ali [1 ]
Ghani, Saud [1 ]
机构
[1] Qatar Univ, Coll Engn, Dept Mech & Ind Engn, POB 2713, Doha, Qatar
关键词
Passive cooling; Variable soil thermal conductivity; Variable soil moisture content; Experimental measurements; Computational Fluid Dynamics (CFD); Parametric analysis;
D O I
10.1016/j.ijrefrig.2020.12.034
中图分类号
O414.1 [热力学];
学科分类号
摘要
High energy consumption and increasing energy cost have encouraged investment in energy efficiency. In hot areas, like the Middle East, the share of space cooling accounts for most of the total energy use in buildings. Earth-to-air heat exchangers represent an energy-efficient and environmentally friendly cooling technique. An earth-to-air heat exchanger buried near the ground surface with short-grass cover, which lowers the soil temperature by evapotranspiration, is an alternative to conventional deep buried types. In this study, a steady three-dimensional numerical model of this earth-to-air heat exchanger was developed by considering the conservation of mass, momentum, energy, and species. Soil temperature and moisture content measurements were used as boundary conditions for the model. In addition, the variations of soil temperature and thermal conductivity with depth were considered in the model. Numerical predictions of temperature matched experimental measurements within +/- 0.5 degrees C. Using the validated numerical model, the effect of inlet air temperature, airflow rate, tube length, material, wall thickness, and soil thermal conductivity on the earth-to-air heat exchanger thermal performance was investigated. Increasing the airflow rate and tube length resulted in an asymptotic increase and decrease in the earth-to-air heat exchanger outlet temperature, respectively. By increasing the tube wall thickness from 1 to 10 mm, the outlet temperature for an aluminum tube remained unchanged, while for PE and PVC tubes, the outlet temperature increased by about 1.1 and 2.2 degrees C, respectively. By increasing the soil thermal conductivity from 1 to 5 W m(-1) K-1 the outlet temperature decreased by about 4.4 degrees C. (C) 2020 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:25 / 33
页数:9
相关论文
共 50 条
  • [41] Thermal performance of air to water heat exchanger with plain surface disc turbulators: experimental and numerical study
    Saurabh Yadav
    Maheandera Prabu Paulraj
    Santosh K. Sahu
    Heat and Mass Transfer, 2020, 56 : 1777 - 1791
  • [42] Thermal performance of air to water heat exchanger with plain surface disc turbulators: experimental and numerical study
    Yadav, Saurabh
    Paulraj, Maheandera Prabu
    Sahu, Santosh K.
    HEAT AND MASS TRANSFER, 2020, 56 (06) : 1777 - 1791
  • [43] Numerical and experimental analysis of the energy performance of an air-source heat pump (ASHP) coupled with a horizontal earth-to-air heat exchanger (EAHX) in different climates
    Congedo, Paolo Maria
    Baglivo, Cristina
    Bonuso, Sara
    D'Agostino, Delia
    GEOTHERMICS, 2020, 87
  • [44] Numerical study of a PCM-air heat exchanger's thermal performance
    Herbinger, F.
    Bhouri, M.
    Groulxl, D.
    7TH EUROPEAN THERMAL-SCIENCES CONFERENCE (EUROTHERM2016), 2016, 745
  • [45] Thermal performance optimization of a semi-nested building coupled with an earth-to-air heat exchanger using iterative Taguchi method
    Lin, Yaolin
    Feng, Haoming
    Yang, Wei
    Hao, Xiaoli
    Tian, Lin
    Yuan, Xingping
    RENEWABLE ENERGY, 2022, 195 : 1275 - 1290
  • [46] Parametric Study and Energy Performance of an Earth-Air Heat Exchanger for a Poultry House in Morocco
    Laknizi, Azzeddine
    Mahdaoui, Mustapha
    Anoune, Kamal
    Bakhouya, Mohamed
    Ben Abdellah, Abdelatif
    Oussous, Hamza
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2018, 8 (04): : 2047 - 2056
  • [47] Evaluation of Thermal Performance of Single Pass Earth-Air Heat Exchanger in Heating Mode
    Deldan, Namgial
    Rajan, Aggarwal
    Hans, Vishavjeet S.
    Kaushal, Arun
    ENVIRONMENTAL PROGRESS & SUSTAINABLE ENERGY, 2017, 36 (04) : 1253 - 1261
  • [48] A numerical study into effects of soil compaction and heat storage on thermal performance of a Horizontal Ground Heat Exchanger
    Tang, F.
    Lahoori, M.
    Nowamooz, H.
    Rosin-Paumier, S.
    Masrouri, F.
    RENEWABLE ENERGY, 2021, 172 : 740 - 752
  • [49] Experimental and numerical study on thermal performance of a fluoride salt-to-air heat exchanger
    Chen, Yu-Shuang
    Tian, Jian
    Zhu, Hai-Hua
    Fu, Yuan
    Wang, Na-Xiu
    ANNALS OF NUCLEAR ENERGY, 2022, 168
  • [50] Numerical parametric study of a new earth-air heat exchanger configuration designed for hot and arid climates
    Benrachi, Naoufel
    Ouzzane, Mohamed
    Smaili, Arezki
    Lamarche, Louis
    Badache, Messaoud
    Maref, Wahid
    INTERNATIONAL JOURNAL OF GREEN ENERGY, 2020, 17 (02) : 115 - 126