Numerical evaluation of the thermal performance of a near-surface earth-to-air heat exchanger with short-grass ground cover: A parametric study

被引:10
|
作者
Pakari, Ali [1 ]
Ghani, Saud [1 ]
机构
[1] Qatar Univ, Coll Engn, Dept Mech & Ind Engn, POB 2713, Doha, Qatar
关键词
Passive cooling; Variable soil thermal conductivity; Variable soil moisture content; Experimental measurements; Computational Fluid Dynamics (CFD); Parametric analysis;
D O I
10.1016/j.ijrefrig.2020.12.034
中图分类号
O414.1 [热力学];
学科分类号
摘要
High energy consumption and increasing energy cost have encouraged investment in energy efficiency. In hot areas, like the Middle East, the share of space cooling accounts for most of the total energy use in buildings. Earth-to-air heat exchangers represent an energy-efficient and environmentally friendly cooling technique. An earth-to-air heat exchanger buried near the ground surface with short-grass cover, which lowers the soil temperature by evapotranspiration, is an alternative to conventional deep buried types. In this study, a steady three-dimensional numerical model of this earth-to-air heat exchanger was developed by considering the conservation of mass, momentum, energy, and species. Soil temperature and moisture content measurements were used as boundary conditions for the model. In addition, the variations of soil temperature and thermal conductivity with depth were considered in the model. Numerical predictions of temperature matched experimental measurements within +/- 0.5 degrees C. Using the validated numerical model, the effect of inlet air temperature, airflow rate, tube length, material, wall thickness, and soil thermal conductivity on the earth-to-air heat exchanger thermal performance was investigated. Increasing the airflow rate and tube length resulted in an asymptotic increase and decrease in the earth-to-air heat exchanger outlet temperature, respectively. By increasing the tube wall thickness from 1 to 10 mm, the outlet temperature for an aluminum tube remained unchanged, while for PE and PVC tubes, the outlet temperature increased by about 1.1 and 2.2 degrees C, respectively. By increasing the soil thermal conductivity from 1 to 5 W m(-1) K-1 the outlet temperature decreased by about 4.4 degrees C. (C) 2020 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:25 / 33
页数:9
相关论文
共 50 条
  • [31] Thermal design of Earth-to-Air Heat Exchanger: Performance analysis of new transient semi-analytical model for short period of continuous operation
    Melhegueg, Mohammed -Amin
    Benchabane, Adel
    Rouag, Amar
    Mehdid, Charaf-Eddine
    Demir, Hakan
    Sevindir, Mustafa Kemal
    Kheireddine, Mohamed-Abdelbassit
    CASE STUDIES IN THERMAL ENGINEERING, 2022, 40
  • [32] Experimental and numerical study of a vertical earth-to-air heat exchanger system integrated with annular phase change material
    Liu, Zhengxuan
    Yu, Zhun
    Yang, Tingting
    El Mankibi, Mohamed
    Roccamena, Letizia
    Sun, Ying
    Sun, Pengcheng
    Li, Shuisheng
    Zhang, Guoqiang
    ENERGY CONVERSION AND MANAGEMENT, 2019, 186 : 433 - 449
  • [33] Performance evaluation of flat rectangular earth-to-air heat exchangers in harmonically fluctuating thermal environments
    Wei, Haibin
    Yang, Dong
    APPLIED THERMAL ENGINEERING, 2019, 162
  • [34] Experimental and Co-Simulation Performance Evaluation of an Earth-to-Air Heat Exchanger System Integrated into a Smart Building
    Kharbouch, Abdelhak
    Berrabah, Soukayna
    Bakhouya, Mohamed
    Gaber, Jaafar
    El Ouadghiri, Driss
    Kaitouni, Samir Idrissi
    ENERGIES, 2022, 15 (15)
  • [35] Modeling and comparative thermal performance of ground air collector and earth air heat exchanger for heating of greenhouse
    Ghosal, MK
    Tiwari, GN
    Das, DK
    Pandey, KP
    ENERGY AND BUILDINGS, 2005, 37 (06) : 613 - 621
  • [36] Modeling and parametric studies for thermal performance of an earth to air heat exchanger in South East Algeria
    Saifi, Nadia
    Settou, Noureddine
    Dokkar, Abdelghani
    2015 6TH INTERNATIONAL RENEWABLE ENERGY CONGRESS (IREC), 2015,
  • [37] Experimental and numerical study of an earth-to-air heat exchanger for air cooling in a residential building in hot semi-arid climate
    Khabbaz, Mohamed
    Benhamou, Brahim
    Limam, Karim
    Hollmuller, Pierre
    Hamdi, Hassan
    Bennouna, Amin
    ENERGY AND BUILDINGS, 2016, 125 : 109 - 121
  • [38] The Optimization of the Thermal Performances of an Earth to Air Heat Exchanger for an Air Conditioning System: A Numerical Study
    Greco, Adriana
    Masselli, Claudia
    ENERGIES, 2020, 13 (23)
  • [39] Performance analysis of domed roof integrated with earth-to-air heat exchanger system to meet thermal comfort conditions in buildings
    Akbarpoor, Ali Mirzazade
    Poshtiri, Amin Haghighi
    Biglari, Faraz
    RENEWABLE ENERGY, 2021, 168 (168) : 1265 - 1293
  • [40] Thermal performance of a single U-tube ground heat exchanger: A parametric study
    Mousavi Ajarostaghi, Seyed Soheil
    Javadi, Hossein
    Mousavi, Seyed Sina
    Poncet, Sebastien
    Pourfallah, Mohsen
    JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2021, 28 (11) : 3580 - 3598