Monte Carlo dose calculation of critical organs in MDR Cs-137 afterloading intracavitary brachytherapy

被引:0
|
作者
Owrangi, A. M. [1 ]
Masudiefar, M. [2 ]
Jaberi, R. [3 ]
Ghahramani, F. [3 ]
Clarkson, R. [1 ]
Chow, J. C. L. [1 ]
机构
[1] Princess Margaret Hosp, Dept Radiat Phys, Toronto, ON M4X 1K9, Canada
[2] Mahak Hosp, Dept Radiat Oncol, Tehran, Iran
[3] Univ Tehran Med Sci, Dept Phys Med, Tehran, Iran
关键词
D O I
10.1118/1.3244106
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
引用
收藏
页码:4304 / 4304
页数:1
相关论文
共 50 条
  • [41] EFFECT OF BEDSIDE SHIELDING ON AIR-KERMA RATES AROUND GYNECOLOGIC INTRACAVITARY BRACHYTHERAPY PATIENTS CONTAINING RA-226 OR CS-137
    PAPIN, PJ
    RAMSEY, MJ
    LAFONTAINE, RL
    LEPAGE, RP
    HEALTH PHYSICS, 1990, 58 (04): : 405 - 410
  • [42] A Monte Carlo Based Dose Calculation and Evaluation Toolkit for Electronic Brachytherapy: Feasibility of IMBT
    Guo, B.
    Cheng, C.
    Director, B.
    Rusch, T.
    Esquivel, C.
    Stathakis, S.
    Shi, C.
    Papanikolaou, N.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [43] Dose effects of stents in intravascular brachytherapy for in-stent restenosis: A Monte Carlo calculation
    Li, XA
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 55 (03): : 842 - 848
  • [44] Evaluation of Collapsed Cone Dose Calculation Algorithm for HDR Brachytherapy Using Monte Carlo
    Volken, W.
    Terribilini, D.
    Fix, M. K.
    Loessl, K.
    van Veelen, B.
    Manser, P.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [45] PATIENT-SPECIFIC MONTE CARLO DOSE CALCULATIONS FOR HIGH-DOSE-RATE ENDORECTAL BRACHYTHERAPY WITH SHIELDED INTRACAVITARY APPLICATOR
    Poon, Emily
    Williamson, Jeffrey F.
    Vuong, Te
    Verhaegen, Frank
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (04): : 1259 - 1266
  • [46] A Monte Carlo dose calculation system for ophthalmic brachytherapy based on a realistic eye model
    Miras del Rio, Hector
    Ortiz Lora, Antonio
    Bertolet Reina, Alejandro
    Terron Leon, Jose Antonio
    MEDICAL PHYSICS, 2021, 48 (08) : 4542 - 4559
  • [47] Monte Carlo and experimental derivation of TG43 dosimetric parameters for CSM-type Cs-137 sources
    Pérez-Calatayud, J
    Granero, D
    Casal, E
    Ballester, F
    Puchades, V
    MEDICAL PHYSICS, 2005, 32 (01) : 28 - 36
  • [48] Monte Carlo dosimetric characterization of the Cs-137 selectron/LDR source:: Evaluation of applicator attenuation and superposition approximation effects
    Pérez-Calatayud, J
    Granero, D
    Ballester, F
    Puchades, V
    Casal, E
    MEDICAL PHYSICS, 2004, 31 (03) : 493 - 499
  • [49] Monte Carlo and experimental TG43 derived data for the CSM-type LDR Cs-137 sources
    Casal, E
    Granero, D
    Ballester, F
    Puchades, V
    Soriano, A
    Pérez-Calatayud, J
    Cases, R
    Agramunt, S
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S243 - S243
  • [50] Parameterization of brachytherapy source phase space file for Monte Carlo-based clinical brachytherapy dose calculation
    Zhang, M.
    Zou, W.
    Chen, T.
    Kim, L.
    Khan, A.
    Haffty, B.
    Yue, N. J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (02): : 455 - 464