Monte Carlo dose calculation of critical organs in MDR Cs-137 afterloading intracavitary brachytherapy

被引:0
|
作者
Owrangi, A. M. [1 ]
Masudiefar, M. [2 ]
Jaberi, R. [3 ]
Ghahramani, F. [3 ]
Clarkson, R. [1 ]
Chow, J. C. L. [1 ]
机构
[1] Princess Margaret Hosp, Dept Radiat Phys, Toronto, ON M4X 1K9, Canada
[2] Mahak Hosp, Dept Radiat Oncol, Tehran, Iran
[3] Univ Tehran Med Sci, Dept Phys Med, Tehran, Iran
关键词
D O I
10.1118/1.3244106
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
引用
收藏
页码:4304 / 4304
页数:1
相关论文
共 50 条
  • [31] Combined experimental and Monte Carlo verification of 137Cs brachytherapy plans for vaginal applicators
    Sloboda, RS
    Wang, RQ
    PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (12): : 3495 - 3507
  • [32] A New Approach for Afterloading Brachytherapy Inverse Planned Dose Optimization Based On the Accurate Monte Carlo Method
    D'Amours, M.
    Carrier, J.
    Lessard, E.
    Pouliot, J.
    Verhaegen, F.
    Beaulieu, L.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [33] Monte Carlo-based investigation of water-equivalence of solid phantoms at Cs-137 energy
    Vishwakarma, Ramkrushna S.
    Selvam, T. Palani
    Sahoo, Sridhar
    Mishra, Subhalaxmi
    Chourasiya, Ghanshyam
    JOURNAL OF MEDICAL PHYSICS, 2013, 38 (04) : 158 - 164
  • [34] Validation of Monte Carlo Calculation on Skin Dose in HDR Brachytherapy for Keloid with PHITS
    Ni, J.
    Zhang, W.
    Xu, X.
    Qin, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2024, 120 (02): : E170 - E170
  • [35] Dose Calculation of a Breast Cancer Brachytherapy Treatment Using Monte Carlo Simulation
    Graf, M.
    Scanderbeg, D.
    Cervino, L.
    Yashar, C.
    Jiang, S.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [36] Monte Carlo calculation of dose rate distributions around the Walstam CDC.K-type 137Cs sources
    Pérez-Calatayud, J
    Ballester, F
    Lluch, JL
    Serrano-Andrés, MA
    Casal, E
    Puchades, V
    Limami, Y
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (07): : 2029 - 2040
  • [37] A Monte Carlo study of intersource effects in dome-type applicators loaded with LDR Cs-137 sources
    Pérez-Calatayud, J
    Granero, D
    Ballester, F
    Lliso, F
    RADIOTHERAPY AND ONCOLOGY, 2005, 77 (02) : 216 - 219
  • [38] LOW DOSE-RATE IRRADIATION OF XENOTRANSPLANTED HUMAN CERVICAL TUMORS BY A SIMPLE CS-137 AFTERLOADING DEVICE - CELL KINETIC EFFECTS
    RUTGERS, DH
    VANOOSTRUM, IEA
    ZEITSCHRIFT FUR VERSUCHSTIERKUNDE, 1986, 28 (1-2): : 95 - 95
  • [39] A CS-137 AFTERLOADING DEVICE - PRELIMINARY-RESULTS OF CELL KINETIC EFFECTS OF LOW DOSE-RATE IRRADIATION IN AN EXPERIMENTAL TUMOR
    RUTGERS, DH
    STRAHLENTHERAPIE UND ONKOLOGIE, 1988, 164 (02): : 105 - 107
  • [40] PATIENT-SPECIFIC MONTE CARLO-BASED DOSE-KERNEL APPROACH FOR INVERSE PLANNING IN AFTERLOADING BRACHYTHERAPY
    D'Amours, Michel
    Pouliot, Jean
    Dagnault, Anne
    Verhaegen, Frank
    Beaulieu, Luc
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (05): : 1582 - 1589