Energy and exergy analysis of a ground source heat pump system with a slinky ground heat exchanger supported by nanofluid

被引:15
|
作者
Kapicioglu, Abdullah [1 ]
机构
[1] Sivas Cumhuriyet Univ, Fac Technol, Dept Mfg Engn, Sivas, Turkey
关键词
Aluminum oxide nanofluid; Horizontal ground source heat pump; Slinky ground heat exchanger; Energy analysis; Exergy analysis; AL2O3; NANOFLUID; TRANSFER ENHANCEMENT; THERMAL PERFORMANCE; BUILDINGS;
D O I
10.1007/s10973-020-10498-0
中图分类号
O414.1 [热力学];
学科分类号
摘要
This work contains the experimental analysis results in real environment conditions of the use of Al2O3-based nanofluid (NF) at different concentration ratios (0.1% and 0.2%) in a ground source heat pump (GSHP) system with a slinky ground heat exchanger (GHE). The energetic and exergic efficiencies of the system were investigated with the data obtained from the experimental results of base fluid (ethylene glycol (EG)-water) (EG volumetric ratio 25%) and NF with Al2O3 concentration ratios of 0.1% and 0.2%. The exergetic model is obtained by applying energy and exergy equations for each system component. Exergetic efficiencies of the system components are evaluated separately and their potential for improvement is presented. According to the results of the energetic analysis, the overall system's coefficient of performance (COP) values for the base fluid and NF with concentration ratios of 0.1% and 0.2% were 4.30, 4.38 and 4.34, respectively. These results show that NF contributes to system performance. However, an increase in system performance was not achieved due to the increase in NF concentration; on the contrary, a decrease in performance was observed. Exergetic efficiencies of the system for base fluid and NF with concentration ratios of 0.1% and 0.2% were 88.3%, 89.7% and 89.0%, respectively, for the heat pump unit, while these values were 78.7%, 79.3% and 79.0% for the entire system, respectively. The results show that the usage of NF with low concentration ratios increases the energetic and exergic efficiency of the system.
引用
收藏
页码:1455 / 1468
页数:14
相关论文
共 50 条
  • [41] Numerical Simulation and Analysis for the U-tube Heat Exchanger of Ground Source Heat Pump
    Chang Zhen
    Guo Min
    2013 32ND CHINESE CONTROL CONFERENCE (CCC), 2013, : 8713 - 8717
  • [42] Influence of ground heat exchanger zoning operation on operation economy of ground source heat pump systems
    Yu M.
    He Z.
    Mao Y.
    Cui P.
    Zhang W.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2022, 43 (01): : 205 - 212
  • [43] Effects of ground heat exchanger variable pipe separation in ground-source heat pump systems
    Makasis, N.
    Narsilio, G. A.
    Bidarmaghz, A.
    Johnston, I. W.
    ENERGY GEOTECHNICS, 2016, : 155 - 161
  • [44] Applicability of the pipe structure and flow velocity of vertical ground heat exchanger for ground source heat pump
    Zhou, Hong
    Lv, Jian
    Li, Tailu
    ENERGY AND BUILDINGS, 2016, 117 : 109 - 119
  • [45] Predictive ANN models of ground heat exchanger for the control of hybrid ground source heat pump systems
    Gang, Wenjie
    Wang, Jinbo
    APPLIED ENERGY, 2013, 112 : 1146 - 1153
  • [46] Energy, exergy and exergoeconomic analysis of solar-assisted vertical ground source heat pump system for heating season
    Fatih Ünal
    Galip Temir
    Hasan Köten
    Journal of Mechanical Science and Technology, 2018, 32 : 3929 - 3942
  • [47] Energy, exergy and exergoeconomic analysis of solar-assisted vertical ground source heat pump system for heating season
    Unal, Fatih
    Temir, Galip
    Koten, Hasan
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2018, 32 (08) : 3929 - 3942
  • [48] Experimental energy and exergy analysis of a ground source heat pump and cooling machine in mild climate conditions
    Arslan, Mevlut
    Kavasogullari, Baris
    Yesilyurt, Murat Kadir
    Igci, Atilla Abir
    Sungur, Aysenur
    INTERNATIONAL JOURNAL OF EXERGY, 2023, 42 (03) : 286 - 301
  • [49] Measured performance of a solar-ground source heat pump system with vertical double spiral coil ground heat exchanger
    Bi, Y.
    Chen, L.
    Wu, C.
    International Journal of Ambient Energy, 2001, 22 (01) : 3 - 11
  • [50] Study for the performance of a solar-ground source heat pump system with vertical double spiral coil ground heat exchanger
    Bi, YH
    Guo, TW
    Zhang, L
    Chen, LG
    PROCEEDINGS OF THE 3RD INTERNATIONAL SYMPOSIUM ON HEAT TRANSFER ENHANCEMENT AND ENERGY CONSERVATION, VOLS 1 AND 2, 2004, : 508 - 515