A Predictive Model for the Long-Term Electrical Performance of a Leadless Transcatheter Pacemaker

被引:13
|
作者
Kiani, Soroosh [1 ]
Wallace, Kristie [2 ]
Stromberg, Kurt [2 ]
Piccini, Jonathan P. [3 ,4 ]
Roberts, Paul R. [5 ]
El-Chami, Mikhael F. [1 ]
Soejima, Kyoko [6 ]
Garweg, Christophe [7 ]
Fagan, Dedra H. [2 ]
Lloyd, Michael S. [1 ]
机构
[1] Emory Univ, Dept Internal Med, Div Cardiol, Sect Cardiac Electrophysiol & Pacing,Sch Med, Atlanta, GA 30322 USA
[2] Medtron PLC, Mounds View, MN USA
[3] Duke Univ, Med Ctr, Durham, NC USA
[4] Duke Clin Res Inst, Durham, NC USA
[5] Univ Hosp Southampton Natl Hlth Serv Fdn Trust, Southampton Gen Hosp, Southampton, Hants, England
[6] Kyorin Univ, Dept Cardiol, Sch Med, Tokyo, Japan
[7] Univ Leuven, Dept Cardiovasc Sci, Leuven, Belgium
关键词
elevated thresholds; leadless pacemaker; predictors; system revision; IMPLANTATION;
D O I
10.1016/j.jacep.2020.09.010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study sought to formulate a predictive model for describing the long-term electrical performance of Micra (Medtronic, Mounds View, Minnesota). BACKGROUND The Micra leadless pacemaker is an alternative ventricular pacing option that avoids the pitfalls of transvenous leads. However, well-defined metrics to predict the long-term electrical performance of the device are lacking. METHODS We identified all patients who underwent successful Micra implantation enrolled in the investigational device exemption study, continued access study, or post-approval registry with complete 1-year post-implantation data or system revision due to elevated thresholds (N = 1,843). The analysis endpoint was an elevated pacing capture threshold (PCT) at >= 12 months post-implantation, defined as >= 2.0 V at 0.24 ms or an increase of >= 1.5 V from implantation or need for system revision due to elevated thresholds at <= 12 months post-implantation. We evaluated for univariate and multivariate associations between patient and device characteristics at implantation and for elevated thresholds at 12 months. RESULTS Among the total cohort, 75 patients (4.1%) had elevated thresholds at 12 months; of these, 13 required system revisions. Predictors associated with elevated thresholds in univariate analysis included the total number of deployments (excluded from the multivariable model), impedance and PCT at implantation, male sex, history of diabetes, and ischemic cardiomyopathy. Multivariable regression modeling found that male sex, history of diabetes, implantation PCT of >= 2 V, and impedance of <800 U were independent predictors of elevated PCT at 12 months (all p < 0.05). CONCLUSION A history of diabetes, male sex, elevated PCT, and low impedance at implantation were independent predictors of elevated thresholds at 12 months. These metrics represent the foundation of a simple tool to aid in procedural decision making. (C) 2021 by the American College of Cardiology Foundation.
引用
收藏
页码:502 / 512
页数:11
相关论文
共 50 条
  • [31] RESULTS OF LONG-TERM PACEMAKER THERAPY
    REEH, K
    ROTTHOFF, F
    HOPF, G
    LANGENBECKS ARCHIV FUR CHIRURGIE, 1971, 329 : 606 - &
  • [32] PACEMAKER OF LONG-TERM CLIMATIC CHANGE
    HAYS, JD
    IMBRIE, J
    SHACKLETON, NJ
    TRANSACTIONS-AMERICAN GEOPHYSICAL UNION, 1976, 57 (04): : 259 - 259
  • [33] Long-term survivors of pacemaker implant
    Furman, S
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (02): : 134 - 135
  • [34] LONG-TERM OF ARTIFICIAL PACEMAKER SYSTEMS
    DRESSLER, L
    GROS, A
    KNORRE, GHV
    KRIEG, B
    OTTE, KB
    PODSZUS, G
    SCHAEDEL, H
    WEBER, D
    WITTE, J
    DEUTSCHE GESUNDHEITSWESEN-ZEITSCHRIFT FUR KLINISCHE MEDIZIN, 1979, 34 (13): : 598 - 605
  • [35] LONG-TERM ELECTROCARDIOGRAPHY IN PACEMAKER PATIENTS
    HAAN, D
    PETZOLD, D
    ZEITSCHRIFT FUR KREISLAUFFORSCHUNG, 1969, 58 (07): : 790 - &
  • [36] LONG-TERM RESULTS WITH AN IMPLANTED PACEMAKER
    GAGE, AA
    FEDERICO, AJ
    SCHIMERT, G
    GREATBAT.W
    CHARDACK, WM
    CIRCULATION, 1965, 32 (4S2) : 92 - &
  • [37] LONG-TERM ECG IN PACEMAKER PATIENTS
    KOTZUR, J
    THEISEN, F
    SCHEININGER, M
    HAUFE, M
    THEISEN, K
    JAHRMARKER, H
    ZEITSCHRIFT FUR KARDIOLOGIE, 1985, 74 : 41 - 41
  • [38] Six-month electrical performance of the first dual-chamber leadless pacemaker
    Hindricks, Gerhard
    Doshi, Rahul
    Defaye, Pascal
    V. Exner, Derek
    Reddy, Vivek Y.
    Knops, Reinoud E.
    Canby, Robert
    Shoda, Morio
    Bongiorni, Maria Grazia
    Neuzil, Petr
    Callahan, Thomas
    Sundaram, Sri
    Badie, Nima
    Ip, James E.
    HEART RHYTHM, 2024, 21 (10) : 1929 - 1938
  • [39] LONG-TERM FOLLOW-UP OF ATRIOVENTRICULAR JUNCTIONAL TRANSCATHETER ELECTRICAL ABLATION
    LEVY, S
    BRU, P
    ALIOT, E
    ATTUEL, P
    BARNAY, C
    CLEMENTY, J
    EBAGOSTI, A
    FAUCHIER, JP
    FONTAINE, G
    LECLERCQ, JF
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (08): : 1149 - 1153
  • [40] Gender Differences in Leadless Pacemaker Peri-Procedural Adverse Events, Long-Term Device Functions, and Clinical Outcomes
    Huang, Jingwen
    Bhatia, Neal
    Lloyd, Michael S.
    Westerman, Stacy
    Shah, Anand
    Leal, Miguel A.
    Delurgio, David B.
    Patel, Anshul
    Tompkins, Christine
    Leon, Angel R.
    CIRCULATION, 2023, 148