A Predictive Model for the Long-Term Electrical Performance of a Leadless Transcatheter Pacemaker

被引:13
|
作者
Kiani, Soroosh [1 ]
Wallace, Kristie [2 ]
Stromberg, Kurt [2 ]
Piccini, Jonathan P. [3 ,4 ]
Roberts, Paul R. [5 ]
El-Chami, Mikhael F. [1 ]
Soejima, Kyoko [6 ]
Garweg, Christophe [7 ]
Fagan, Dedra H. [2 ]
Lloyd, Michael S. [1 ]
机构
[1] Emory Univ, Dept Internal Med, Div Cardiol, Sect Cardiac Electrophysiol & Pacing,Sch Med, Atlanta, GA 30322 USA
[2] Medtron PLC, Mounds View, MN USA
[3] Duke Univ, Med Ctr, Durham, NC USA
[4] Duke Clin Res Inst, Durham, NC USA
[5] Univ Hosp Southampton Natl Hlth Serv Fdn Trust, Southampton Gen Hosp, Southampton, Hants, England
[6] Kyorin Univ, Dept Cardiol, Sch Med, Tokyo, Japan
[7] Univ Leuven, Dept Cardiovasc Sci, Leuven, Belgium
关键词
elevated thresholds; leadless pacemaker; predictors; system revision; IMPLANTATION;
D O I
10.1016/j.jacep.2020.09.010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study sought to formulate a predictive model for describing the long-term electrical performance of Micra (Medtronic, Mounds View, Minnesota). BACKGROUND The Micra leadless pacemaker is an alternative ventricular pacing option that avoids the pitfalls of transvenous leads. However, well-defined metrics to predict the long-term electrical performance of the device are lacking. METHODS We identified all patients who underwent successful Micra implantation enrolled in the investigational device exemption study, continued access study, or post-approval registry with complete 1-year post-implantation data or system revision due to elevated thresholds (N = 1,843). The analysis endpoint was an elevated pacing capture threshold (PCT) at >= 12 months post-implantation, defined as >= 2.0 V at 0.24 ms or an increase of >= 1.5 V from implantation or need for system revision due to elevated thresholds at <= 12 months post-implantation. We evaluated for univariate and multivariate associations between patient and device characteristics at implantation and for elevated thresholds at 12 months. RESULTS Among the total cohort, 75 patients (4.1%) had elevated thresholds at 12 months; of these, 13 required system revisions. Predictors associated with elevated thresholds in univariate analysis included the total number of deployments (excluded from the multivariable model), impedance and PCT at implantation, male sex, history of diabetes, and ischemic cardiomyopathy. Multivariable regression modeling found that male sex, history of diabetes, implantation PCT of >= 2 V, and impedance of <800 U were independent predictors of elevated PCT at 12 months (all p < 0.05). CONCLUSION A history of diabetes, male sex, elevated PCT, and low impedance at implantation were independent predictors of elevated thresholds at 12 months. These metrics represent the foundation of a simple tool to aid in procedural decision making. (C) 2021 by the American College of Cardiology Foundation.
引用
收藏
页码:502 / 512
页数:11
相关论文
共 50 条
  • [21] A PREDICTIVE MODEL FOR LONG-TERM SHORELINE CHANGE
    Li Shao-wu (Department of Harbor and coastal Engineering
    Journal of Hydrodynamics(SerB)., 1999, (01) : 56 - 63
  • [22] Analytical predictive model for the long-term bond performance of CFRP tendons in concrete
    Toumpanaki, Eleni
    Lees, Janet M.
    Terrasi, Giovanni P.
    COMPOSITE STRUCTURES, 2020, 250
  • [23] A NEW MODEL FOR PACEMAKER CONTROL USING LONG-TERM ELECTROGRAPHY
    BETHGE, KP
    DISTLER, WK
    GONSKA, BD
    KREUZER, H
    ZEITSCHRIFT FUR KARDIOLOGIE, 1985, 74 : 41 - 41
  • [24] Leadless pacemaker used as long-term temporary therapy in Lyme carditis with high-grade atrioventricular block
    Isath, Ameesh
    Padmanabhan, Deepak
    Naksuk, Niyada
    Kella, Danesh
    Friedman, Paul
    EUROPACE, 2019, 21 (01): : 8 - 8
  • [25] Short-Term Safety and Performance of a Single-Chamber Leadless Pacemaker
    Watanabe, Eiichi
    CIRCULATION JOURNAL, 2023, 87 (12) : 1817 - 1819
  • [26] LONG-TERM OUTCOMES IN PATIENTS RECEIVING PERMANENT PACEMAKER AFTER TRANSCATHETER AORTIC VALVE REPLACEMENT
    Stathogiannis, Konstantinos
    Toutouzas, Konstantinos
    Spargias, Konstantinos
    Latsios, George
    Synetos, Andreas
    Brili, Styliani
    Mastrokostopoulos, Antonios
    Chrissoheris, Michael
    Halapas, Antonios
    Adoniades, Aias
    Pavlides, Gregory
    Stefanadis, Christodoulos I.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) : A1742 - A1742
  • [27] Pacemaker dependency after transcatheter aortic valve implantation: incidence, predictors and long-term outcomes
    Costa, Giuliano
    Zappulla, Paolo
    Barbanti, Marco
    Cirasa, Arianna
    Todaro, Denise
    Rapisarda, Giulia
    Picci, Andrea
    Platania, Francesco
    Tosto, Antonio
    Di Grazia, Angelo
    Sgroi, Carmelo
    Tamburino, Corrado
    Calvi, Valeria
    EUROINTERVENTION, 2019, 15 (10) : 875 - +
  • [28] Pacemaker dependency after transcatheter aortic valve implantation: incidence, predictors and long-term outcomes
    Zappulla, Paolo
    Costa, Giuliano
    Barbanti, Marco
    Cirasa, Arianna
    Todaro, Denise
    Rapisarda, Giulia
    Picci, Andrea
    Platania, Francesco
    Tosto, Antonio
    Di Grazia, Angelo
    Sgroi, Carmelo
    Tamburino, Corrado
    Calvi, Valeria
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2019, 21 (0J) : J111 - J111
  • [29] LONG-TERM OBSERVATION OF PACEMAKER ELECTRODES
    LAGERGREN, H
    EDHAG, O
    LAFOLETTE, L
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1979, 2 (05): : A65 - A65
  • [30] ACUTE AND LONG-TERM PERFORMANCE OF SMALL-TIPPED PACEMAKER ELECTRODES
    PICCONE, VA
    SUAREZ, F
    IMPERIO, J
    KHAN, R
    ELSHERIF, N
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1979, 2 (05): : A66 - A66