Imaging of ungrouted tendon ducts in prestressed concrete by improved SIBIE

被引:17
|
作者
Ata, Ninel [1 ]
Mihara, Shinichi [1 ]
Ohtsu, Masayasu [1 ]
机构
[1] Kumamoto Univ, Grad Sch Sci & Technol, Kumamoto 8608555, Japan
关键词
impact-echo method; SIBIE; boundary element method (BEM);
D O I
10.1016/j.ndteint.2006.10.008
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The impact-echo method has been extensively applied to nondestructive evaluation of defects in concrete structures. The presence and the location of defects in concrete are estimated by identifying peak frequencies in the frequency spectra. To detect ungrouted tendon ducts, the method is known to be available. However, because post-tensioning prestressed concrete members usually have thin web portions, spectra obtained could include many peak frequencies. As a result, it is often problematic to select appropriate peak frequencies associated with the presence of ungrouted ducts. Stack imaging of spectral amplitudes based on impact-echo (SIBIE) is developed, in order to improve the impact-echo and to visually identify the locations of such reflectors as voids and defects. In the present paper, SIBIE is successfully applied to identify ungrouted metal and plastic sheaths at the hunch portion of a prestressed concrete beam. Two-dimensional dynamic BEM analysis is performed to investigate the relations between peak frequencies and locations of reflectors. At the peak frequencies in the spectra, locations of stress concentration are correlated with the response modes. (C) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:258 / 264
页数:7
相关论文
共 50 条
  • [41] VTOP - an improved software for design optimization of prestressed concrete beams
    Hemandez, S.
    Marcos, D.
    Fontan, A. N.
    Diaz, J.
    COMPUTER AIDED OPTIMUM DESIGN IN ENGINEERING X, 2007, 91 : 151 - +
  • [43] Calculation of crack width of steel-concrete composite beams prestressed with internal tendon
    Jiang Shuan
    Bai Lili
    Xue Weichen
    ADVANCES IN APPLIED SCIENCES AND MANUFACTURING, PTS 1 AND 2, 2014, 850-851 : 183 - +
  • [44] Fragility analysis of prestressed concrete girder bridges to traffic loads considering tendon corrosion
    Nettis, Alessandro
    Nettis, Andrea
    Ruggieri, Sergio
    Uva, Giuseppina
    EUROPEAN ASSOCIATION ON QUALITY CONTROL OF BRIDGES AND STRUCTURES, EUROSTRUCT 2023, VOL 6, ISS 5, 2023, : 794 - 800
  • [45] Effect of Tendon-Related Variables on the Behavior of Externally CFRP Prestressed Concrete Beams
    Lou, Tiejiong
    Hu, Han
    Pang, Miao
    MATERIALS, 2023, 16 (14)
  • [46] Deflection behavior of prestressed concrete beam using fiber reinforced polymer (FRP) tendon
    Selvachandran P.
    Anandakumar S.
    Muthuramu K.L.
    Open Civil Engineering Journal, 2016, 10 : 40 - 60
  • [47] Ultrasonic inspection of tendon ducts in concrete slabs using 3D-SAFT
    Krause, M
    Muller, W
    Wiggenhauser, H
    ACOUSTICAL IMAGING, VOL 23, 1997, 23 : 433 - 439
  • [48] Investigation of the applicability of infrared thermography detection of grouting voids in prestressed tendon ducts under hydration heat excitation
    Li, Shengli
    Gao, Xing
    Wang, Jiangfei
    Yang, Quan
    Jiang, Nan
    Zheng, Pengfei
    Cui, Can
    Han, Shanling
    Sun, Shiji
    NDT & E INTERNATIONAL, 2024, 143
  • [49] Ultrasonic measurements of grouted tendon ducts in concrete structures using Elop Insight Scanner
    Chapagain, Kamal Raj
    Bjerke, Werner
    Wagle, Sanat
    e-Journal of Nondestructive Testing, 2022, 27 (09):
  • [50] Detection of tendon ducts and rebars and the accuracy of the measured concrete cover using ultrasonic echo
    Taffe, Alexander
    Bernhard, Niklas
    BETON- UND STAHLBETONBAU, 2022, 117 (07) : 460 - 471