Imaging of ungrouted tendon ducts in prestressed concrete by improved SIBIE

被引:17
|
作者
Ata, Ninel [1 ]
Mihara, Shinichi [1 ]
Ohtsu, Masayasu [1 ]
机构
[1] Kumamoto Univ, Grad Sch Sci & Technol, Kumamoto 8608555, Japan
关键词
impact-echo method; SIBIE; boundary element method (BEM);
D O I
10.1016/j.ndteint.2006.10.008
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The impact-echo method has been extensively applied to nondestructive evaluation of defects in concrete structures. The presence and the location of defects in concrete are estimated by identifying peak frequencies in the frequency spectra. To detect ungrouted tendon ducts, the method is known to be available. However, because post-tensioning prestressed concrete members usually have thin web portions, spectra obtained could include many peak frequencies. As a result, it is often problematic to select appropriate peak frequencies associated with the presence of ungrouted ducts. Stack imaging of spectral amplitudes based on impact-echo (SIBIE) is developed, in order to improve the impact-echo and to visually identify the locations of such reflectors as voids and defects. In the present paper, SIBIE is successfully applied to identify ungrouted metal and plastic sheaths at the hunch portion of a prestressed concrete beam. Two-dimensional dynamic BEM analysis is performed to investigate the relations between peak frequencies and locations of reflectors. At the peak frequencies in the spectra, locations of stress concentration are correlated with the response modes. (C) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:258 / 264
页数:7
相关论文
共 50 条
  • [21] Detection of grouting defects in prestressed tendon ducts using distributed fiber optic sensors
    Gong, Shilin
    Feng, Xin
    STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2020, 19 (04): : 1273 - 1286
  • [22] Assessment of methods predicting tendon loss and concrete compression loss in partially prestressed concrete
    Chouman, M
    ISUMA 2003: FOURTH INTERNATIONAL SYMPOSIUM ON UNCERTAINTY MODELING AND ANALYSIS, 2003, : 430 - 435
  • [23] CONCRETE PRACTICE SHEET .37. GROUTING OF TALL VERTICAL PRESTRESSED DUCTS
    不详
    CONCRETE, 1978, 12 (05): : 63 - 64
  • [24] Progressive collapse behavior of prestressed concrete frames with various tendon profiles
    Huang, Yuan
    Tao, Yuxuan
    Yi, Weijian
    JOURNAL OF BUILDING ENGINEERING, 2023, 72
  • [25] FLEXURAL STRENGTH OF PRESTRESSED CONCRETE BEAMS WITH TENDON WRAPPED BY PLASTIC SHEETS
    Wang, Ta-Heng
    Huang, Ran
    Chang, Jiang-Jhy
    JOURNAL OF MARINE SCIENCE AND TECHNOLOGY-TAIWAN, 2013, 21 (01): : 76 - 81
  • [26] NDE of tendon ducts in concrete using 3D-SAFT
    Krause, K
    Wiggenhauser, H
    Muller, W
    Schmitz, V
    NONDESTRUCTIVE CHARACTERIZATION OF MATERIALS IN AGING SYSTEMS, 1998, 503 : 237 - 242
  • [27] Performance of FRP tendon-anchor systems for prestressed concrete structures
    Nanni, A
    Bakis, CE
    ONeill, EF
    Dixon, TO
    PCI JOURNAL, 1996, 41 (01): : 34 - &
  • [28] Structural behavior of tendon coupling joints in prestressed concrete bridge girders
    Oh, BH
    Chae, ST
    ACI STRUCTURAL JOURNAL, 2001, 98 (01) : 87 - 95
  • [29] Subsequent Strengthening of Prestressed Concrete Bridges at the Tendon Coupling Joints with Reinforced Concrete Connectors.
    Koenig, Gert
    Quitmann, Horst Dietrich
    Stuelb, Joerg
    Weigler, Helmut
    Beton- und Stahlbetonbau, 1980, 75 (10) : 229 - 235
  • [30] Improved prestressed concrete girder with hybrid segments system
    Yim, Hong Jae
    Yang, Jun Mo
    Kim, Jin Kook