CT angiography versus intraarterial digital subtraction angiography for assessment of aortoiliac occlusive disease

被引:56
|
作者
Rieker, O [1 ]
Duber, C [1 ]
Neufang, A [1 ]
Pitton, M [1 ]
Schweden, F [1 ]
Thelen, M [1 ]
机构
[1] UNIV MAINZ,DEPT CARDIOTHORAC & VASC SURG,D-55131 MAINZ,GERMANY
关键词
D O I
10.2214/ajr.169.4.9308477
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to evaluate the accuracy of CT angiography (CTA) with a single helical acquisition for assessment of stenoses and occlusions of the iliac arteries. SUBJECTS AND METHODS, In our prospective study, intraarterial digital subtraction angiography and TV CTA were performed from the suprarenal aorta to below the femoral bifurcation in 30 patients with vascular occlusive disease. Maximum-intensity-projection images in multiple views were also obtained. The accuracy of CTA with and without analysis of axial images was determined. RESULTS, Sensitivity and specificity of CTA were 100% for iliac artery occlusions with a confidence interval 85-100% and 97-100%, respectively. When axial scans were interpreted, 14 of 15 high-grade (>75%) stenoses were recognized. Sensitivity and specificity of CTA were 93% (range, 68-100%) and 99% (range, 97-100%), respectively. When maximum intensity projections alone were analyzed, sensitivity for the diagnosis of 15 high-grade stenoses was only 53% (range, 27-79%) because calcified plaques obscured six stenoses. CONCLUSION. CTA accurately reveals iliac artery occlusions. Observers of CT angiograms may overlook short stenoses in rare instances. Calcified plaques limit the use of maximum-intensity-projection images.
引用
收藏
页码:1133 / 1138
页数:6
相关论文
共 50 条
  • [31] INTRAARTERIAL DIGITAL SUBTRACTION ANGIOGRAPHY OF RENAL-TRANSPLANTS
    ROEREN, T
    HAUENSTEIN, K
    DINKEL, E
    KIRSTE, G
    UROLOGIC RADIOLOGY, 1986, 8 (02) : 77 - 80
  • [32] PEDIATRIC DIGITAL SUBTRACTION ANGIOGRAPHY - INTRAARTERIAL AND INTRACARDIAC APPLICATIONS
    TONKIN, ILD
    FITCH, SJ
    MAGILL, HL
    GERALD, BE
    GOLD, RE
    ALPERT, BS
    CHASE, NA
    WATSON, DC
    PEDIATRIC RADIOLOGY, 1986, 16 (02) : 126 - 130
  • [33] DIGITAL SUBTRACTION CEREBRAL-ANGIOGRAPHY BY INTRAARTERIAL INJECTION - COMPARISON WITH CONVENTIONAL ANGIOGRAPHY
    BRANTZAWADZKI, M
    GOULD, R
    NORMAN, D
    NEWTON, TH
    LANE, B
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1983, 140 (02) : 347 - 353
  • [34] Value of the CT angiography in the diagnosis of common carotid artery bifurcation disease: CT angiography versus digital subtraction angiography and color flow Doppler
    Moll, R
    Dinkel, HP
    EUROPEAN JOURNAL OF RADIOLOGY, 2001, 39 (03) : 155 - 162
  • [35] INTRAARTERIAL DIGITAL SUBTRACTION ANGIOGRAPHY IN HYPERTENSIVE AZOTEMIC PATIENTS
    ILLESCAS, FF
    FORD, K
    BRAUN, SD
    DUNNICK, NR
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 143 (05) : 1065 - 1067
  • [36] Comparative study between multi-detector CT angiography and digital subtraction angiography in evaluation of peripheral arterial occlusive disease
    Qenawy, Omran Khodary
    Tantawy, Wahid Hussein
    Abdalla, Abdel Karem Hasan
    Sayed, Samy Abdel Aziz
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2015, 46 (04): : 1003 - 1010
  • [37] EVALUATION OF EXTRA-CRANIAL OCCLUSIVE DISEASE BY DIGITAL SUBTRACTION ANGIOGRAPHY
    TURSKI, PA
    STROTHER, CM
    TURNIPSEED, WD
    SACKETT, JF
    CRUMMY, AB
    LIEBERMAN, RP
    STIEGHORST, MF
    SURGICAL NEUROLOGY, 1981, 16 (06): : 394 - 398
  • [38] Photon-Counting Detector CT Angiography Versus Digital Subtraction Angiography in Patients with Peripheral Arterial Disease
    Augustin, Anne Marie
    Hartung, Viktor
    Grunz, Jan-Peter
    Hennes, Jan-Lucca
    Huflage, Henner
    Bley, Thorsten Alexander
    Petritsch, Bernhard
    Gruschwitz, Philipp
    ACADEMIC RADIOLOGY, 2024, 31 (07) : 2973 - 2986
  • [39] INTRAARTERIAL DIGITAL SUBTRACTION ANGIOGRAPHY AS A METHOD TO STUDY PERIPHERAL VASCULAR-DISEASE
    BLAKEMAN, BM
    LITTOOY, FN
    BAKER, WH
    JOURNAL OF VASCULAR SURGERY, 1986, 4 (02) : 168 - 173
  • [40] THE VALUE OF HYOSCINE BUTYLBROMIDE IN AORTOILIAC INTRAVENOUS DIGITAL SUBTRACTION ANGIOGRAPHY
    BENNETT, C
    PHILLIPS, GWL
    COLTHURST, JR
    THOMAS, ML
    VASA-JOURNAL OF VASCULAR DISEASES, 1987, 16 (03): : 262 - 264