CT angiography versus intraarterial digital subtraction angiography for assessment of aortoiliac occlusive disease

被引:56
|
作者
Rieker, O [1 ]
Duber, C [1 ]
Neufang, A [1 ]
Pitton, M [1 ]
Schweden, F [1 ]
Thelen, M [1 ]
机构
[1] UNIV MAINZ,DEPT CARDIOTHORAC & VASC SURG,D-55131 MAINZ,GERMANY
关键词
D O I
10.2214/ajr.169.4.9308477
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to evaluate the accuracy of CT angiography (CTA) with a single helical acquisition for assessment of stenoses and occlusions of the iliac arteries. SUBJECTS AND METHODS, In our prospective study, intraarterial digital subtraction angiography and TV CTA were performed from the suprarenal aorta to below the femoral bifurcation in 30 patients with vascular occlusive disease. Maximum-intensity-projection images in multiple views were also obtained. The accuracy of CTA with and without analysis of axial images was determined. RESULTS, Sensitivity and specificity of CTA were 100% for iliac artery occlusions with a confidence interval 85-100% and 97-100%, respectively. When axial scans were interpreted, 14 of 15 high-grade (>75%) stenoses were recognized. Sensitivity and specificity of CTA were 93% (range, 68-100%) and 99% (range, 97-100%), respectively. When maximum intensity projections alone were analyzed, sensitivity for the diagnosis of 15 high-grade stenoses was only 53% (range, 27-79%) because calcified plaques obscured six stenoses. CONCLUSION. CTA accurately reveals iliac artery occlusions. Observers of CT angiograms may overlook short stenoses in rare instances. Calcified plaques limit the use of maximum-intensity-projection images.
引用
收藏
页码:1133 / 1138
页数:6
相关论文
共 50 条
  • [21] DUPLEX ULTRASONOGRAPHY, INTRAVENOUS DIGITAL SUBTRACTION ANGIOGRAPHY, INTRAARTERIAL DIGITAL SUBTRACTION ANGIOGRAPHY AND CONVENTIONAL ANGIOGRAPHY IN ASSESSING CAROTID ATHEROSCLEROSIS
    MENDEL, HJ
    OLBERT, F
    SCHLEGL, A
    NEBOSIS, M
    ANNALES DE RADIOLOGIE, 1987, 30 (02) : 115 - 120
  • [22] INTRAARTERIAL DIGITAL SUBTRACTION ANGIOGRAPHY - A COMPARATIVE VIEW
    KAUFMAN, SL
    CHANG, R
    KADIR, S
    MITCHELL, SE
    WHITE, RI
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1983, 6 (4-6) : 271 - 279
  • [23] INTRAARTERIAL DIGITAL SUBTRACTION ANGIOGRAPHY VS CONVENTIONAL ANGIOGRAPHY OF ABDOMINAL DISEASES
    NAKAGAWA, N
    TAKAHASHI, M
    BUSSAKA, H
    MIYAWAKI, M
    COMPUTERIZED RADIOLOGY, 1985, 9 (03): : 137 - 143
  • [24] CLINICAL-ASSESSMENT OF INTRAVENOUS AND INTRAARTERIAL DIGITAL SUBTRACTION ANGIOGRAPHY (DSA)
    SCHLEGL, A
    OLBERT, F
    MENDEL, HJ
    NEBOSIS, M
    ANNALES DE RADIOLOGIE, 1987, 30 (02) : 120 - 120
  • [25] Pedal Angiography in Peripheral Arterial Occlusive Disease: First-Pass IV Contrast-Enhanced MR Angiography with Blood Pool Contrast Medium Versus Intraarterial Digital Subtraction Angiography
    Kos, Sebastian
    Reisinger, Clemens
    Aschwanden, Markus
    Bongartz, Georg M.
    Jacob, Augustinus L.
    Bilecen, Deniz
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (03) : 775 - 784
  • [26] Multidetector CT angiography versus digital subtraction angiography in the detection of intracranial aneurysms
    Jayaraman, MV
    Mayo-Smith, WW
    Haas, RA
    Rogg, JM
    Mehta, NR
    Tung, GA
    RADIOLOGY, 2002, 225 : 521 - 522
  • [27] Intracranial stenoocclusive disease:: Double-detector helical CT angiography versus digital subtraction angiography
    Skutta, B
    Fürst, G
    Eilers, J
    Ferbert, A
    Kuhn, FP
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1999, 20 (05) : 791 - 799
  • [28] Cerebral veins: Comparative study of CT venography with intraarterial digital subtraction angiography
    Wetzel, SG
    Kirsch, E
    Stock, KW
    Kolbe, M
    Kaim, A
    Radue, EW
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1999, 20 (02) : 249 - 255
  • [29] Contrast media nephropathy: Intravenous CT angiography versus intraarterial digital subtraction angiography in renal artery stenosis: A prospective randomized trial
    Lufft, V
    Hoogestraat-Lufft, L
    Fels, LM
    Egbeyong-Baiyee, D
    Tusch, G
    Galanski, M
    Olbricht, CJ
    AMERICAN JOURNAL OF KIDNEY DISEASES, 2002, 40 (02) : 236 - 242
  • [30] INTRAARTERIAL DIGITAL SUBTRACTION ANGIOGRAPHY OF RENAL-TRANSPLANTS
    PICUS, D
    NEELEY, JP
    MCCLENNAN, BL
    WEYMAN, PJ
    HEIKEN, JP
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1985, 145 (01) : 93 - 96