Modelling of detective quantum efficiency of direct conversion x-ray imaging detectors incorporating charge carrier trapping and K-fluorescence

被引:10
|
作者
Kabir, M. Z. [1 ]
Rahman, M. W. [1 ]
Shen, W. Y. [1 ]
机构
[1] Concordia Univ, Dept Elect & Comp Engn, Montreal, PQ H3G 1M8, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
ACTIVE-MATRIX READOUT; AMORPHOUS SELENIUM; DIGITAL FLUOROSCOPY; A-SE; RESOLUTION; PROTOTYPE; IMAGERS; SYSTEMS;
D O I
10.1049/iet-cds.2010.0338
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A cascaded linear system model is developed for calculating the frequency-dependent detective quantum efficiency, DQE(f), of a direct conversion x-ray imaging detector by incorporating the effects of charge carrier trapping and reabsorption of K-fluorescent x-rays. The present model considers a combination of series and parallel processes and interactions between them. The modulation transfer function for K-fluorescent x-ray reabsorption is modelled by determining the line spread function and subsequent one-dimensional Fourier transform. The DQE model is applied to amorphous selenium (a-Se) and polycrystalline mercuric iodide (poly-HgI(2)) detectors. The charge carrier trapping has a significant effect on DQE in both a-Se and poly-HgI(2) detectors. The charge carrier transport properties have higher influences on DQE performance in a-Se detectors than that in HgI(2) detectors, because of relatively low conversion gain in a-Se detectors. High conversion gain can minimise the adverse effect of incomplete charge collection. A simplified model for the calculation of zero spatial frequency detective quantum efficiency, DQE(0), under parallel cascaded system is also proposed in this study. There exists an optimum photoconductor thickness, which maximises the DQE(0). The proposed model is compared with the published measured data and shows good agreement.
引用
收藏
页码:222 / 231
页数:10
相关论文
共 50 条
  • [41] Monte Carlo analyses of C-ray absorption, noise, and detective quantum efficiency considering therapeutic X-ray spectrum in portal imaging detector
    Cho, G
    Kim, HK
    Chung, YH
    Kim, DK
    Lee, HK
    Suh, TS
    Joo, KS
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (04) : 1423 - 1427
  • [42] Calculation of detective quantum efficiency for CMOS image sensor coupled with micro-channel plate in low energy X-ray imaging
    Chi, YK
    Cho, G
    Ahn, SK
    Kim, YS
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 1657 - 1661
  • [43] Technical Note: Impact on detective quantum efficiency of edge angle determination method by International Electrotechnical Commission methodology for cardiac x-ray image detectors
    Gislason-Lee, Amber J.
    Tunstall, Clare M.
    Kengyelics, Stephen K.
    Cowen, Arnold R.
    Davies, Andrew G.
    MEDICAL PHYSICS, 2015, 42 (08) : 4423 - 4427
  • [44] First detective quantum efficiency measurement of 500 μm silicon hybrid pixel sensor with photon counting readout for X-ray medical imaging
    Surre, B
    Caria, M
    Chaput, J
    Hassoun, T
    Laverroux, F
    Sarry, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 546 (1-2): : 24 - 27
  • [45] A-Site Cation Engineering of Ruddlesden-Popper Perovskites for Stable, Sensitive, and Portable Direct Conversion X-ray Imaging Detectors
    Xin, Deyu
    Zhang, Min
    Fan, Zhenghui
    Yang, Ning
    Yuan, Ruihan
    Cai, Bing
    Yu, Ping
    Zheng, Xiaojia
    Zhu, Jianguo
    JOURNAL OF PHYSICAL CHEMISTRY LETTERS, 2022, 13 (51): : 11928 - 11935
  • [46] Direct monitoring of the potassium charge carrier in Prussian blue cathodes using potassium K-edge X-ray absorption spectroscopy
    Mayer, Alexander J.
    Beynon, Owain T.
    Logsdail, Andrew J.
    Wijayantha, K. G. Upul
    Dann, Sandra E.
    Marco, Jose F.
    Elliott, Joshua D.
    Aramini, Matteo
    Cibin, Giannantonio
    Kondrat, Simon A.
    JOURNAL OF MATERIALS CHEMISTRY A, 2023, 11 (37) : 19900 - 19913
  • [47] Development of high quantum efficiency, flat panel, thick detectors for megavoltage x-ray imaging: An experimental study of a single-pixel prototype
    Mei, X
    Pang, G
    MEDICAL PHYSICS, 2005, 32 (11) : 3379 - 3388
  • [48] Evaluation of Relationship between Grain Morphology and Growth Temperature of HgI2 Poly-Films for Direct Conversion X-ray Imaging Detectors
    Xu, Gang
    Yao, Ming
    Zhang, Mingtao
    Zhu, Jinmeng
    Wei, Yongxing
    Gu, Zhi
    Zhang, Lan
    CRYSTALS, 2022, 12 (01)
  • [49] Absolute determination of charge-coupled device quantum detection efficiency using Si K-edge x-ray absorption fine structure
    Dunn, J.
    Steel, A. B.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (10):
  • [50] BEST IN PHYSICS (IMAGING): First Experimental Demonstration of Inter-Detector Row X-Ray Scattering in Edge-On Silicon Photon Counting CT: Impacts On Detective Quantum Efficiency
    De Caro, C.
    Li, K.
    MEDICAL PHYSICS, 2022, 49 (06) : E549 - E549