Modelling of detective quantum efficiency of direct conversion x-ray imaging detectors incorporating charge carrier trapping and K-fluorescence

被引:10
|
作者
Kabir, M. Z. [1 ]
Rahman, M. W. [1 ]
Shen, W. Y. [1 ]
机构
[1] Concordia Univ, Dept Elect & Comp Engn, Montreal, PQ H3G 1M8, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
ACTIVE-MATRIX READOUT; AMORPHOUS SELENIUM; DIGITAL FLUOROSCOPY; A-SE; RESOLUTION; PROTOTYPE; IMAGERS; SYSTEMS;
D O I
10.1049/iet-cds.2010.0338
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A cascaded linear system model is developed for calculating the frequency-dependent detective quantum efficiency, DQE(f), of a direct conversion x-ray imaging detector by incorporating the effects of charge carrier trapping and reabsorption of K-fluorescent x-rays. The present model considers a combination of series and parallel processes and interactions between them. The modulation transfer function for K-fluorescent x-ray reabsorption is modelled by determining the line spread function and subsequent one-dimensional Fourier transform. The DQE model is applied to amorphous selenium (a-Se) and polycrystalline mercuric iodide (poly-HgI(2)) detectors. The charge carrier trapping has a significant effect on DQE in both a-Se and poly-HgI(2) detectors. The charge carrier transport properties have higher influences on DQE performance in a-Se detectors than that in HgI(2) detectors, because of relatively low conversion gain in a-Se detectors. High conversion gain can minimise the adverse effect of incomplete charge collection. A simplified model for the calculation of zero spatial frequency detective quantum efficiency, DQE(0), under parallel cascaded system is also proposed in this study. There exists an optimum photoconductor thickness, which maximises the DQE(0). The proposed model is compared with the published measured data and shows good agreement.
引用
收藏
页码:222 / 231
页数:10
相关论文
共 50 条
  • [31] Measurement of the detective quantum efficiency (DQE) of digital X-ray detectors according to the novel standard IEC 62220-1
    Illers, H
    Buhr, E
    Hoeschen, C
    RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) : 39 - 44
  • [32] Monte-Carlo Simulation of the Detective Quantum Efficiency of Cadmium Telluride X-Ray Detectors for Photon-Counting Mammography
    Day, J.
    Tanguay, J.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [33] Simultaneous X-ray fluorescence and K-edge CT imaging with photon-counting detectors
    Li, Liang
    Li, Ruizhe
    Zhang, Siyuan
    Chen, Zhiqiang
    DEVELOPMENTS IN X-RAY TOMOGRAPHY X, 2016, 9967
  • [34] Segmented phosphors; MEMS-based high quantum efficiency detectors for megavoltage x-ray imaging
    Sawant, A
    Antonuk, LE
    El-Mohri, Y
    Li, YX
    Su, Z
    Wang, Y
    Yamamoto, J
    Zhao, QH
    Du, H
    Daniel, J
    Street, R
    MEDICAL PHYSICS, 2005, 32 (02) : 553 - 565
  • [35] Segmented crystalline scintillators: An initial investigation of high quantum efficiency detectors for megavoltage x-ray imaging
    Sawant, A
    Antonuk, LE
    El-Mohri, Y
    Zhao, QH
    Li, YX
    Su, Z
    Wang, Y
    Yamamoto, J
    Du, H
    Cunningham, I
    Klugerman, M
    Shah, K
    MEDICAL PHYSICS, 2005, 32 (10) : 3067 - 3083
  • [36] Analysis of factors affecting the estimation of detective quantum efficiency of digital X-ray detectors within high and low spatial frequency ranges
    Zelikman M.I.
    Kabanov S.P.
    Kruchinin S.A.
    Lobov D.P.
    Biomedical Engineering, 2007, 41 (5) : 210 - 213
  • [37] Measurement of the Detective Quantum Efficiency (DQE) of digital X-ray imaging devices according to the standard IEC 62220-1
    Illers, H
    Buhr, E
    Bergmann, D
    Hoeschen, C
    MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 : 177 - 187
  • [38] Cascaded-systems analyses and the detective quantum efficiency of single-Z x-ray detectors including photoelectric, coherent and incoherent interactions
    Yun, Seungman
    Tanguay, Jesse
    Kim, Ho Kyung
    Cunningham, Ian A.
    MEDICAL PHYSICS, 2013, 40 (04)
  • [39] Detective quantum efficiency for photon-counting hybrid pixel detectors in the tender X-ray domain: application to Medipix3RX
    Rinkel, Jean
    Magalhaes, Debora
    Wagner, Franz
    Meneau, Florian
    Vicentin, Flavio Cesar
    JOURNAL OF SYNCHROTRON RADIATION, 2016, 23 : 206 - 213
  • [40] Direct-conversion X-ray imaging detectors for medical, non-destructive testing (NDT), and other applications
    Lee, DLY
    Golden, KP
    Yorker, JG
    Rodricks, BG
    Cheung, LK
    Jeromin, LS
    PENETRATING RADIATION SYSTEMS AND APPLICATIONS III, 2001, 4508 : 1 - 14