A simple and sensitive sensor based on a molecularly imprinted polymer-modified carbon paste electrode for the determination of curcumin in foods

被引:19
|
作者
Zhou, Q. [1 ]
Zhai, H. Y. [1 ]
Pan, Y. F. [2 ]
Li, K. [1 ]
机构
[1] GuangDong Pharmaceut Univ, Dept Pharm, Guangzhou 510006, Guangdong, Peoples R China
[2] GuangDong Pharmaceut Univ, Dept Chem, Zhongshan 528458, Peoples R China
基金
中国国家自然科学基金;
关键词
VOLTAMMETRIC DETERMINATION; QUANTITATION; SURFACE; PLASMA; ACID;
D O I
10.1039/c7ra02253k
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A highly sensitive and selective molecularly imprinted polymer-modified carbon paste electrode (MIP-CPE) was designed. The curcumin molecularly imprinted polymer (CUR-MIP) was prepared by thermally induced precipitation polymerization, using curcumin (CUR) as the template molecule, methacrylic acid (MAA) as the functional monomer, 2,20-azodiisobutyronitrile (AIBN) as the initiator, and ethylene glycol dimethacrylate (EDGMA) as the cross-linker. The modified electrode was prepared by mixing the polymer, graphite powder, and paraffin oil in specific proportions. The electrochemical behaviour of CUR on this electrode was studied, and a method for direct CUR determination using this electrode was established. The results showed that CUR exhibited a distinct oxidation peak (Epa) at 0.434 V (vs. SCE) in the mixed phosphate buffer solution (PBS) at pH 3.06. The optimum addition ratio of the polymer in the modified electrode was 20%, and the peak current (Ipa) was 4.5-fold higher than that of the bare CPE. The Ipa showed a good linear relationship with concentration in the range 0.1-50 mu M, and the detection limit was 10.1 nM. The method was applied to determine CUR contents in food, giving recovery rates of 90.77-105.7%.
引用
收藏
页码:22913 / 22918
页数:6
相关论文
共 50 条
  • [31] A Molecularly Imprinted Polymer-modified Potentiometric Sensor for the Detection of Glutathione
    Konishi, Atsuko
    Takegami, Shigehiko
    Kitade, Tatsuya
    ANALYTICAL SCIENCES, 2019, 35 (10) : 1111 - 1115
  • [32] A Molecularly Imprinted Polymer-modified Potentiometric Sensor for the Detection of Glutathione
    Atsuko Konishi
    Shigehiko Takegami
    Tatsuya Kitade
    Analytical Sciences, 2019, 35 : 1111 - 1115
  • [33] Application of Molecularly Imprinted Polymer-modified Potentiometric Sensor for Quantitative Determination of Histamine in Serum
    Konishi, Atsuko
    Takegami, Shigehiko
    Idosaki, Yoko
    Kitade, Tatsuya
    ANALYTICAL SCIENCES, 2020, 36 (12) : 1561 - 1563
  • [34] Application of Molecularly Imprinted Polymer-modified Potentiometric Sensor for Quantitative Determination of Histamine in Serum
    Atsuko Konishi
    Shigehiko Takegami
    Yoko Idosaki
    Tatsuya Kitade
    Analytical Sciences, 2020, 36 : 1561 - 1563
  • [35] Voltammetric sensor for vanillylmandelic acid based on molecularly imprinted polymer-modified electrodes
    Blanco-López, MC
    Lobo-Castañón, MJ
    Miranda-Ordieres, AJ
    Tuñón-Blanco, P
    BIOSENSORS & BIOELECTRONICS, 2003, 18 (04): : 353 - 362
  • [36] An ultrasensitive and selective electrochemical sensor for determination of estrone 3-sulfate sodium salt based on molecularly imprinted polymer modified carbon paste electrode
    Song, Han
    Wang, Yuli
    Zhang, Lu
    Tian, Liping
    Luo, Jun
    Zhao, Na
    Han, Yajie
    Zhao, Feilang
    Ying, Xue
    Li, Yingchun
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2017, 409 (27) : 6509 - 6519
  • [37] An ultrasensitive and selective electrochemical sensor for determination of estrone 3-sulfate sodium salt based on molecularly imprinted polymer modified carbon paste electrode
    Han Song
    Yuli Wang
    Lu Zhang
    Liping Tian
    Jun Luo
    Na Zhao
    Yajie Han
    Feilang Zhao
    Xue Ying
    Yingchun Li
    Analytical and Bioanalytical Chemistry, 2017, 409 : 6509 - 6519
  • [38] In Situ Voltammetric Determination of Promethazine on Carbon Paste Electrode Modified with Nano-sized Molecularly Imprinted Polymer
    Akhoundian, Maedeh
    Alizadeh, Taher
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2020, 12 (07): : 1014 - 1024
  • [39] Electroanalytical determination of sulfasalazine in pharmaceutical and biological samples using molecularly imprinted polymer modified carbon paste electrode
    Sadeghi, Susan
    Motaharian, Ali
    Moghaddam, Ali Zeraatkar
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 168 : 336 - 344
  • [40] Development of a Creatinine Sensor Based on a Molecularly Imprinted Polymer-Modified Sol-Gel Film on Graphite Electrode
    Patel, Amit Kumar
    Sharma, Piyush Sindhu
    Prasad, Bhim Bali
    ELECTROANALYSIS, 2008, 20 (19) : 2102 - 2112