Development of a 32-channel ASIC for an X-ray APD detector onboard the ISS

被引:2
|
作者
Arimoto, Makoto [1 ,2 ]
Harita, Shohei [2 ]
Sugita, Satoshi [2 ]
Yatsu, Yoichi [2 ]
Kawai, Nobuyuki [2 ]
Ikeda, Hirokazu [3 ]
Tomida, Hiroshi [3 ]
Isobe, Naoki [3 ]
Ueno, Shiro [4 ]
Mihara, Tatehiro [5 ]
Serino, Motoko [5 ]
Kohmura, Takayoshi [6 ]
Sakamoto, Takanori [7 ]
Yoshida, Atsumasa [7 ]
Tsunemi, Hiroshi [8 ]
Hatori, Satoshi [9 ]
Kume, Kyo [9 ]
Hasegawa, Takashi [9 ]
机构
[1] Waseda Univ, Res Inst Sci & Engn, Shinjuku Ku, 3-4-1 Ohkubo, Tokyo 1698555, Japan
[2] Tokyo Inst Technol, Meguro Ku, 2-12-1 Ookayama, Tokyo 1528550, Japan
[3] ISAS, 3-1-1 Yoshinodai, Sagamihara, Kanagawa 2298510, Japan
[4] Japan Aerosp Explorat Agcy JAXA, ISAS, ISS Sci Project Off, 2-1-1 Sengen, Tsukuba, Ibaraki 3058505, Japan
[5] RIKEN, MAXI Team, 2-1 Hirosawa, Wako, Saitama 3510198, Japan
[6] Tokyo Univ Sci, Dept Phys, 2641 Yamazaki, Noda, Chiba 2788510, Japan
[7] Aoyama Gakuin Univ, Dept Phys & Math, Coll Sci & Engn, Chuo Ku, 5-10-1 Fuchinobe, Sagamihara, Kanagawa 2525258, Japan
[8] Osaka Univ, Dept Earth & Space Sci, 1-1 Machikaneyama Cho, Toyonaka, Osaka 5600043, Japan
[9] Wakasa Wan Energy Res Ctr, 64-52-1 Nagatani, Tsuruga, Fukui 9140192, Japan
关键词
ASIC; Low-noise; X-rays; APD; Radiation tolerance;
D O I
10.1016/j.nima.2017.09.003
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We report on the design and performance of a mixed-signal application specific integrated circuit (ASIC) dedicated to avalanche photodiodes (APDs) in order to detect hard X-ray emissions in a wide energy band onboard the International Space Station. To realize wide-band detection from 20 keV to 1 MeV, we use Ce:GAGG scintillators, each coupled to an APD, with low-noise front-end electronics capable of achieving a minimum energy detection threshold of 20 keV. The developed ASIC has the ability to read out 32-channel APD signals using 0.35 mu m CMOS technology, and an analog amplifier at the input stage is designed to suppress the capacitive noise primarily arising from the large detector capacitance of the APDs. The ASIC achieves a performance of 2099 e(-) + 1.5 e(-) /pF at root mean square (RMS) with a wide 300 fC dynamic range. Coupling a reverse-type APD with a Ce:GAGG scintillator, we obtain an energy resolution of 6.7% (FWHM) at 662 keV and a minimum detectable energy of 20 keV at room temperature (20 degrees C). Furthermore, we examine the radiation tolerance for space applications by using a 90 MeV proton beam, confirming that the ASIC is free of single-event effects and can operate properly without serious degradation in analog and digital processing. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:138 / 147
页数:10
相关论文
共 50 条
  • [31] ISS-Lobster: a low-cost wide-field X-ray transient detector on the ISS
    Camp, Jordan
    Barthelmy, Scott
    Petre, Rob
    Gehrels, Neil
    Marshall, Francis
    Ptak, Andy
    Racusin, Judith
    EUV AND X-RAY OPTICS: SYNERGY BETWEEN LABORATORY AND SPACE IV, 2015, 9510
  • [32] Solar Intensity X-Ray Spectrometer (SIXS) ASIC onboard the ESA BepiColombo mission to Mercury
    Khalid, F. F.
    Prydderch, M. L.
    Morrissey, Q.
    Seller, P.
    Valtonen, E.
    Peltonen, J.
    Syrjaesuo, M.
    Vainio, R.
    Huovelin, J.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2097 - +
  • [33] Development of an ASIC for multi-readout X-ray CCDs
    Matsuura, Daisuke
    Nakajima, Hiroshi
    Miyata, Emi
    Tsunemi, Hiroshi
    Doty, John P.
    Ikeda, Hirokazu
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 1073 - 1077
  • [34] Development of STJ as a new X-ray detector
    Yamasaki, NY
    Ohashi, T
    Kikuchi, K
    Miyazaki, H
    Rokutanda, E
    Kushino, A
    Kurakado, M
    HOT UNIVERSE, 1998, (188): : 335 - 336
  • [35] Development of a digital X-ray imaging detector
    Ronnqvist, C
    Pedersen, F
    Fransson, K
    Gustafsson, L
    Kullander, S
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 1607 - 1611
  • [36] Progress in development on CdZnTe x-ray detector
    Zhou, Yongdong
    Zhou, Ning
    Zhang, Linhu
    Wang, Jin
    Wan, Aihua
    SEMICONDUCTOR PHOTODETECTORS III, 2006, 6119
  • [37] The Development of a Readout ASIC for a TPC BASED X-Ray Polarimeter
    Zhang, H. Y.
    He, L.
    Deng, Z.
    Feng, H.
    Ji, J. F.
    Zeng, M.
    Liu, Y. N.
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [38] Development of an ASIC for multi-readout X-ray CCDs
    Matsuura, D.
    Nakajima, H.
    Anabuki, N.
    Tsunemi, H.
    Doty, J. P.
    Ikeda, H.
    Katayama, H.
    HIGH ENERGY, OPTICAL, AND INFRARED DETECTORS FOR ASTRONOMY III, 2008, 7021
  • [39] Hard X-ray calibration facility design for JEM-X detector onboard of INTEGRAL
    Pareschi, G
    Frontera, F
    Pelliciari, C
    Zavattini, G
    Carassiti, V
    Evangelisti, F
    EUX, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY VIII, 1997, 3114 : 404 - 411
  • [40] Development of an X-ray imaging detector for high-energy X-ray microtomography
    Hoshino, Masato
    Uesugi, Kentaro
    Yagi, Naoto
    JOURNAL OF SYNCHROTRON RADIATION, 2020, 27 : 934 - 940