Development of a 32-channel ASIC for an X-ray APD detector onboard the ISS

被引:2
|
作者
Arimoto, Makoto [1 ,2 ]
Harita, Shohei [2 ]
Sugita, Satoshi [2 ]
Yatsu, Yoichi [2 ]
Kawai, Nobuyuki [2 ]
Ikeda, Hirokazu [3 ]
Tomida, Hiroshi [3 ]
Isobe, Naoki [3 ]
Ueno, Shiro [4 ]
Mihara, Tatehiro [5 ]
Serino, Motoko [5 ]
Kohmura, Takayoshi [6 ]
Sakamoto, Takanori [7 ]
Yoshida, Atsumasa [7 ]
Tsunemi, Hiroshi [8 ]
Hatori, Satoshi [9 ]
Kume, Kyo [9 ]
Hasegawa, Takashi [9 ]
机构
[1] Waseda Univ, Res Inst Sci & Engn, Shinjuku Ku, 3-4-1 Ohkubo, Tokyo 1698555, Japan
[2] Tokyo Inst Technol, Meguro Ku, 2-12-1 Ookayama, Tokyo 1528550, Japan
[3] ISAS, 3-1-1 Yoshinodai, Sagamihara, Kanagawa 2298510, Japan
[4] Japan Aerosp Explorat Agcy JAXA, ISAS, ISS Sci Project Off, 2-1-1 Sengen, Tsukuba, Ibaraki 3058505, Japan
[5] RIKEN, MAXI Team, 2-1 Hirosawa, Wako, Saitama 3510198, Japan
[6] Tokyo Univ Sci, Dept Phys, 2641 Yamazaki, Noda, Chiba 2788510, Japan
[7] Aoyama Gakuin Univ, Dept Phys & Math, Coll Sci & Engn, Chuo Ku, 5-10-1 Fuchinobe, Sagamihara, Kanagawa 2525258, Japan
[8] Osaka Univ, Dept Earth & Space Sci, 1-1 Machikaneyama Cho, Toyonaka, Osaka 5600043, Japan
[9] Wakasa Wan Energy Res Ctr, 64-52-1 Nagatani, Tsuruga, Fukui 9140192, Japan
关键词
ASIC; Low-noise; X-rays; APD; Radiation tolerance;
D O I
10.1016/j.nima.2017.09.003
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We report on the design and performance of a mixed-signal application specific integrated circuit (ASIC) dedicated to avalanche photodiodes (APDs) in order to detect hard X-ray emissions in a wide energy band onboard the International Space Station. To realize wide-band detection from 20 keV to 1 MeV, we use Ce:GAGG scintillators, each coupled to an APD, with low-noise front-end electronics capable of achieving a minimum energy detection threshold of 20 keV. The developed ASIC has the ability to read out 32-channel APD signals using 0.35 mu m CMOS technology, and an analog amplifier at the input stage is designed to suppress the capacitive noise primarily arising from the large detector capacitance of the APDs. The ASIC achieves a performance of 2099 e(-) + 1.5 e(-) /pF at root mean square (RMS) with a wide 300 fC dynamic range. Coupling a reverse-type APD with a Ce:GAGG scintillator, we obtain an energy resolution of 6.7% (FWHM) at 662 keV and a minimum detectable energy of 20 keV at room temperature (20 degrees C). Furthermore, we examine the radiation tolerance for space applications by using a 90 MeV proton beam, confirming that the ASIC is free of single-event effects and can operate properly without serious degradation in analog and digital processing. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:138 / 147
页数:10
相关论文
共 50 条
  • [21] Development of a CdTe pixel detector with a window comparator ASIC for high energy X-ray applications
    Hirono, T.
    Toyokawa, H.
    Furukawa, Y.
    Honma, T.
    Ikeda, H.
    Kawase, M.
    Koganezawa, T.
    Ohata, T.
    Sato, M.
    Sato, G.
    Takagaki, M.
    Takahashi, T.
    Watanabe, S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 650 (01): : 88 - 91
  • [22] Pixel readout ASIC for an APD based 2D X-ray hybrid pixel detector with sub-nanosecond resolution
    Thil, Ch.
    Baron, A. Q. R.
    Fajardo, P.
    Fischer, P.
    Graafsma, H.
    Rueffer, R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 628 (01): : 461 - 464
  • [23] A 32-channel preamplifier chip for the multiplicity vertex detector at PHENIX
    Britton, CL
    Clonts, LG
    Ericson, MN
    Frank, SS
    Moore, JA
    Simpson, ML
    Young, GR
    Smith, RS
    Boissevain, J
    Hahn, S
    Kapustinsky, JS
    Simon-Gillo, J
    Sullivan, JP
    van Hecke, H
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (03): : 1684 - 1687
  • [24] Detector Development for X-ray Imaging
    Mentzer, M. A.
    Herr, D. A.
    Brewer, K. J.
    Ojason, N.
    Tarpine, H. A.
    OPTICAL COMPONENTS AND MATERIALS VII, 2010, 7598
  • [25] A 32-Channel ASIC for the Readout of Pixelated Liquid Argon Time Projection Chambers
    Grace, C. R.
    Dwyer, D. A.
    Garcia-Sciveres, M.
    Gnani, D.
    Kohn, S.
    Krieger, A.
    Luk, K-B
    Madigan, P.
    Steiner, H.
    Stezelberger, T.
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [26] Development of a two-dimensional ASIC for hard X-ray spectroscopy and imaging with a CdTe pixel detector
    Hiruta, Tatsuro
    Tamura, K.
    Ikeda, H.
    Nakazawa, K.
    Takasima, T.
    Takahashi, T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 565 (01): : 258 - 262
  • [27] Preliminary observing achievements of super soft X-ray detector and Γ-ray detector onboard Shenzhou2
    Zhang, N
    Tang, HS
    Chang, J
    Zhang, HQ
    Gan, WQ
    Gu, FY
    Shen, QZ
    Xu, YL
    Cai, MS
    Gong, YZ
    ENERGY RELEASE AND PARTICLE ACCELERATION IN THE SOLAR ATMOSPHERE - FLARES AND RELATED PHENOMENA, 2003, 32 (12): : 2579 - 2583
  • [28] TGV32: A 32-channel preamplifier chip for the multiplicity vertex detector at PHENIX
    Britton, CL
    Ericson, MN
    Frank, SS
    Moore, JA
    Simpson, ML
    Young, GR
    Smith, RS
    Clonts, LG
    Parakkat, TB
    Boissevain, J
    Hahn, S
    Kapustinsky, JS
    Simon-Gillo, J
    Sullivan, JP
    van Hecke, H
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 231 - 235
  • [29] Multi-channel charge readout ASIC for X-ray detection
    Liu H.
    Xu L.
    Tian T.
    Xi'an Dianzi Keji Daxue Xuebao/Journal of Xidian University, 2021, 48 (04): : 97 - 102and112
  • [30] Design of a 32-channel High-performance OpenPET Detector Board
    Peng, Q.
    Moses, W. W.
    Vu, C.
    Huber, J. S.
    Choong, W. -S.
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,