High-kVp Assisted Metal Artifact Reduction for X-Ray Computed Tomography

被引:15
|
作者
Xi, Yan [1 ]
Jin, Yannan [3 ]
De Man, Bruno [4 ]
Wang, Ge [2 ]
机构
[1] Rensselaer Polytech Inst, Troy, NY 12180 USA
[2] Rensselaer Polytech Inst, Biomed Imaging Ctr Cluster, Troy, NY 12180 USA
[3] GE Global Res, Image Reconstruct Lab, Niskayuna, NY 12309 USA
[4] GE Global Res, Niskayuna, NY 12309 USA
来源
IEEE ACCESS | 2016年 / 4卷
关键词
Computed tomography; metal artifact reduction; kVp switching; iterative reconstruction; DUAL-ENERGY CT; RECONSTRUCTION; ALGORITHM; SUPPRESSION; PROTOCOL; IMAGE;
D O I
10.1109/ACCESS.2016.2602854
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In X-ray computed tomography (CT), the presence of metallic parts in patients causes serious artifacts and degrades image quality. Many algorithms were published for metal artifact reduction (MAR) over the past decades with various degrees of success but without a perfect solution. Some MAR algorithms are based on the assumption that metal artifacts are due only to strong beam hardening and may fail in the case of serious photon starvation. Iterative methods handle photon starvation by discarding or underweighting corrupted data, but the results are not always stable and they come with high computational cost. In this paper, we propose a high-kVp-assisted CT scan mode combining a standard CT scan with a few projection views at a high-kVp value to obtain critical projection information near the metal parts. This method only requires minor hardware modifications on a modern CT scanner. Two MAR algorithms are proposed: dual-energy normalized MAR (DNMAR) and high-energy embedded MAR (HEMAR), aiming at situations without and with photon starvation respectively. Simulation results obtained with the CT simulator CatSim demonstrate that the proposed DNMAR and HEMAR methods can eliminate metal artifacts effectively.
引用
收藏
页码:4769 / 4776
页数:8
相关论文
共 50 条
  • [31] Polarized x-ray excitation for scatter reduction in x-ray fluorescence computed tomography
    Vernekohl, Don
    Tzoumas, Stratis
    Zhao, Wei
    Xing, Lei
    MEDICAL PHYSICS, 2018, 45 (08) : 3741 - 3748
  • [32] Metal-induced streak artifact reduction using iterative reconstruction algorithms in x-ray computed tomography image of the dentoalveolar region
    Dong, Jian
    Hayakawa, Yoshihiko
    Kannenberg, Sven
    Kober, Cornelia
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2013, 115 (02): : E63 - E73
  • [33] Metal Artifact Reduction in X-ray CT via Ray Profile Correction
    Ha, Sungsoo
    Mueller, Klaus
    APPLIED SCIENCES-BASEL, 2020, 10 (01):
  • [34] Using Experiment and Simulation to Understand the Effects of Source Filtering on Artifact Reduction for Industrial X-ray Computed Tomography
    Roth, Don
    MATERIALS EVALUATION, 2020, 78 (02) : 203 - 212
  • [35] Normalized metal artifact reduction (NMAR) in computed tomography
    Meyer, Esther
    Raupach, Rainer
    Lell, Michael
    Schmidt, Bernhard
    Kachelriess, Marc
    MEDICAL PHYSICS, 2010, 37 (10) : 5482 - 5493
  • [36] Metal Artifact Reduction in Computed Tomography by Constrained Optimization
    Zhang, Xiaomeng
    Wang, Jing
    Xing, Lei
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [37] Normalized Metal Artifact Reduction (NMAR) in Computed Tomography
    Meyer, Esther
    Bergner, Frank
    Raupach, Rainer
    Flohr, Thomas
    Kachelriess, Marc
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3251 - +
  • [38] Evaluation of Metal Artifact Reduction software in Computed Tomography
    Eslam M.
    Abdelaziz M.
    Eslam, Mamoun, 1600, Mashhad University of Medical Sciences (17): : 298 - 302
  • [39] Using Experiment and Simulation to Understand the Effects of Source Filtering on Artifact Reduction for Industrial X-ray Computed Tomography
    Roth, Don (don.roth@bhge.com), 1600, American Society for Nondestructive Testing (78):
  • [40] X-RAY COMPUTED TOMOGRAPHY
    HORN, E
    ELECTRONICS AND POWER, 1978, 24 (01): : 36 - 41