High-kVp Assisted Metal Artifact Reduction for X-Ray Computed Tomography

被引:15
|
作者
Xi, Yan [1 ]
Jin, Yannan [3 ]
De Man, Bruno [4 ]
Wang, Ge [2 ]
机构
[1] Rensselaer Polytech Inst, Troy, NY 12180 USA
[2] Rensselaer Polytech Inst, Biomed Imaging Ctr Cluster, Troy, NY 12180 USA
[3] GE Global Res, Image Reconstruct Lab, Niskayuna, NY 12309 USA
[4] GE Global Res, Niskayuna, NY 12309 USA
来源
IEEE ACCESS | 2016年 / 4卷
关键词
Computed tomography; metal artifact reduction; kVp switching; iterative reconstruction; DUAL-ENERGY CT; RECONSTRUCTION; ALGORITHM; SUPPRESSION; PROTOCOL; IMAGE;
D O I
10.1109/ACCESS.2016.2602854
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In X-ray computed tomography (CT), the presence of metallic parts in patients causes serious artifacts and degrades image quality. Many algorithms were published for metal artifact reduction (MAR) over the past decades with various degrees of success but without a perfect solution. Some MAR algorithms are based on the assumption that metal artifacts are due only to strong beam hardening and may fail in the case of serious photon starvation. Iterative methods handle photon starvation by discarding or underweighting corrupted data, but the results are not always stable and they come with high computational cost. In this paper, we propose a high-kVp-assisted CT scan mode combining a standard CT scan with a few projection views at a high-kVp value to obtain critical projection information near the metal parts. This method only requires minor hardware modifications on a modern CT scanner. Two MAR algorithms are proposed: dual-energy normalized MAR (DNMAR) and high-energy embedded MAR (HEMAR), aiming at situations without and with photon starvation respectively. Simulation results obtained with the CT simulator CatSim demonstrate that the proposed DNMAR and HEMAR methods can eliminate metal artifacts effectively.
引用
收藏
页码:4769 / 4776
页数:8
相关论文
共 50 条
  • [21] Metal artifact correction for x-ray computed tomography using kV and selective MV imaging
    Wu, Meng
    Keil, Andreas
    Constantin, Dragos
    Star-Lack, Josh
    Zhu, Lei
    Fahrig, Rebecca
    MEDICAL PHYSICS, 2014, 41 (12)
  • [22] Metal artifact removal (MAR) analysis for the security inspections using the X-ray computed tomography
    Cho, Hyo Sung
    Woo, Tae Ho
    Park, Chul Kyu
    RADIATION PHYSICS AND CHEMISTRY, 2016, 127 : 42 - 47
  • [23] High spatial resolution x-ray luminescence computed tomography and x-ray fluorescence computed tomography
    Dai, Xianjin
    Sivasubramanian, Kathyayini
    Xing, Lei
    MOLECULAR-GUIDED SURGERY: MOLECULES, DEVICES, AND APPLICATIONS V, 2019, 10862
  • [24] Metal Artifact Reduction in X-ray Computed Tomography Using Computer-Aided Design Data of Implants as Prior Information
    Ruth, Veikko
    Kolditz, Daniel
    Steiding, Christian
    Kalender, Willi A.
    INVESTIGATIVE RADIOLOGY, 2017, 52 (06) : 349 - 359
  • [25] Computed Tomography Artifact Created by Air in the X-ray Tube Oil
    Hedrick, Wayne R.
    Markovic, Michael A.
    Short, James H.
    Vera, Chido D.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2016, 40 (01) : 67 - 70
  • [26] The Nature of Metal Artifacts in X-ray Computed Tomography and Their Reduction by Optimization of Tomography Systems Parameters
    Osipov, Sergey Pavlovich
    Chakhlov, Sergei Vladimirovich
    Zhvyrblia, Vadim Yurevich
    Sednev, Dmitry Andreevich
    Osipov, Oleg Sergeyevich
    Usachev, Eugeny Yurevich
    APPLIED SCIENCES-BASEL, 2023, 13 (04):
  • [27] Adaptive streak artifact reduction in computed tomography resulting from excessive x-ray photon noise
    Hsieh, J
    MEDICAL PHYSICS, 1998, 25 (11) : 2139 - 2147
  • [28] Characterization of Metal Artifacts in X-Ray Computed Tomography
    Park, Hyoung Suk
    Choi, Jae Kyu
    Seo, Jin Keun
    COMMUNICATIONS ON PURE AND APPLIED MATHEMATICS, 2017, 70 (11) : 2191 - 2217
  • [29] Comparative Methods for Metal Artifact Reduction in x-ray CT
    Abdoli, Mehrsima
    Mehranian, Abolfazl
    Ailianou, Angeliki
    Becker, Minerva
    Zaidi, Habib
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [30] A hybrid metal artifact reduction algorithm for x-ray CT
    Zhang, Yanbo
    Yan, Hao
    Jia, Xun
    Yang, Jian
    Jiang, Steve B.
    Mou, Xuanqin
    MEDICAL PHYSICS, 2013, 40 (04)