Sutureless 27-gauge needle-assisted transconjunctival intrascleral intraocular lens fixation: Initial experience

被引:45
|
作者
Kelkar, Aditya Shrikant [1 ]
Fogla, Rajesh [2 ]
Kelkar, Jai [1 ]
Kothari, Akshay Anil [1 ]
Mehta, Hetal [1 ]
Amoaku, Winfried [3 ]
机构
[1] Natl Inst Ophthalmol, Dept Ophthalmol, Pune, Maharashtra, India
[2] Apollo Hlth City, Dept Ophthalmol, Hyderabad, Telangana, India
[3] Univ Nottingham, Dept Ophthalmol, Nottingham, England
关键词
Endothelial cell density; intraocular pressure; macular thickness; modified Yamane's double-needle technique and flanged haptics; transconjunctival intrascleral intraocular lens fixation; visual outcomes; CHAMBER; IMPLANTATION; EYES; IOL;
D O I
10.4103/ijo.IJO_659_17
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The purpose of the study was to report our initial experience with the transconjunctival Intrascleral Intraocular Lens (SFIOL) fixation with modified Yamane's double-needle technique and flanged haptics. Methods: This was a prospective interventional study that enrolled 31 consecutive patients undergoing SFIOL with the modified Yamane's technique. All patients underwent comprehensive evaluation including uncorrected and best-corrected vision, intraocular pressure, ultrasound biomicroscopy, endothelial cell density, and macular thickness using optical coherence tomography (OCT). We excluded patients with visually significant coexistent pathology such as corneal scars, macular pathology, and glaucoma. Results: The mean age of subjects was 57 +/- 16.9 years and 23 were men (74%). Surgery was performed for aphakia following complicated cataract surgery in 10 eyes (32%), with lensectomy for subluxated/dislocated cataract in 6 eyes (19%), and with IOL explantation for subluxated/dislocated IOL in 15 eyes (48%). There were no intraoperative complications. Uncorrected visual acuity improved from median of 1.48 logarithm of minimum angle of resolution (logMAR) units (interquartile range [IQR] = 1.3-2 logMAR) at baseline to 0.3 logMAR (IQR = 0.2-0.4 logMAR) at 6 weeks (P < 0.001) which was maintained at 6 months. There were no significant changes in endothelial cell density (P = 0.34) and OCT-based macular thickness (P = 0.31) at 6 months. Two eyes had slight IOL decentration. Conclusion: Our initial experience suggests that the Yamane's technique for SFIOL is a simple procedure with a short-learning curve and is independent of scleral flaps, tunnels, sutures, and fibrin glue. Using widely available 27-gauge needle instead of 30-gauge thin wall needle as originally described by Yamane makes it possible for the use of various three-piece IOLs available globally. Further studies are required for widespread acceptance of this technique.
引用
收藏
页码:1450 / 1453
页数:4
相关论文
共 50 条
  • [31] Outcomes of transconjunctival sutureless 27-gauge vitrectomy with silicone oil infusion
    Toygar, Okan
    Mi, Cindy W.
    Miller, Daniel M.
    Riemann, Christopher D.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2016, 254 (11) : 2111 - 2118
  • [32] A 27-Gauge Instrument System for Transconjunctival Sutureless Microincision Vitrectomy Surgery
    Oshima, Yusuke
    Wakabayashi, Taku
    Sato, Tatsuhiko
    Ohji, Masahito
    Tano, Yasuo
    OPHTHALMOLOGY, 2010, 117 (01) : 93 - U122
  • [33] Endoscope-Assisted Sutureless Intrascleral Haptic Fixation of a Posterior Chamber Intraocular Lens
    Tandias, Rachel
    Lemire, Colin A.
    Yu, Gina
    Seto, Brendan
    Arroyo, Jorge G.
    JOURNAL OF VITREORETINAL DISEASES, 2022, 6 (04) : 290 - 294
  • [34] Refractive errors after sutureless intrascleral fixation of intraocular lens
    Masato Kakisu
    Takayuki Baba
    Tomoaki Tatsumi
    Takehito Iwase
    Tomohiro Nizawa
    Gen Miura
    Shuichi Yamamoto
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2021, 259 : 3003 - 3009
  • [35] Sutureless intrascleral posterior chamber intraocular lens fixation Reply
    Akimoto, Masayuki
    Taguchi, Hogara
    Takahashi, Toshihide
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (05): : 854 - 855
  • [36] Refractive errors after sutureless intrascleral fixation of intraocular lens
    Kakisu, Masato
    Baba, Takayuki
    Tatsumi, Tomoaki
    Iwase, Takehito
    Nizawa, Tomohiro
    Miura, Gen
    Yamamoto, Shuichi
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2021, 259 (10) : 3003 - 3009
  • [37] Sutureless intrascleral fixation using a uniquely designed intraocular lens
    Colantuono, D.
    Seknazi, D.
    Miere, A.
    Amoroso, F.
    Glacet-Bernard, A.
    Souied, E. H.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2021, 44 (07): : 957 - 961
  • [38] Clinical experience of two sutureless intrascleral fixation techniques for secondary intraocular lens implantation
    Januschowski, Kai
    Rickmann, Annekatrin
    Boden, Karl
    Ehrlich-Treuenstaett, Gregor V.
    Wakili, Philip
    Bisorca-Gassendorf, Lukas
    OPHTHALMOLOGICA, 2024, 247 (01) : 1 - 7
  • [39] Needle-Assisted Fixation with a Necktie Knot of One Dislocated Haptic of an Intraocular Lens
    Kim, Jung-Yeul
    Iwase, Takeshi
    Lee, Jong-Eun
    Lee, Sung-Bok
    Lee, Yeon-Hee
    Jo, Young-Joon
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2011, 55 (02) : 168 - 169
  • [40] Needle-assisted fixation with a necktie knot of one dislocated haptic of an intraocular lens
    Jung-Yeul Kim
    Takeshi Iwase
    Jong-Eun Lee
    Sung-Bok Lee
    Yeon-Hee Lee
    Young-Joon Jo
    Japanese Journal of Ophthalmology, 2011, 55 : 168 - 169