Sutureless 27-gauge needle-assisted transconjunctival intrascleral intraocular lens fixation: Initial experience

被引:45
|
作者
Kelkar, Aditya Shrikant [1 ]
Fogla, Rajesh [2 ]
Kelkar, Jai [1 ]
Kothari, Akshay Anil [1 ]
Mehta, Hetal [1 ]
Amoaku, Winfried [3 ]
机构
[1] Natl Inst Ophthalmol, Dept Ophthalmol, Pune, Maharashtra, India
[2] Apollo Hlth City, Dept Ophthalmol, Hyderabad, Telangana, India
[3] Univ Nottingham, Dept Ophthalmol, Nottingham, England
关键词
Endothelial cell density; intraocular pressure; macular thickness; modified Yamane's double-needle technique and flanged haptics; transconjunctival intrascleral intraocular lens fixation; visual outcomes; CHAMBER; IMPLANTATION; EYES; IOL;
D O I
10.4103/ijo.IJO_659_17
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The purpose of the study was to report our initial experience with the transconjunctival Intrascleral Intraocular Lens (SFIOL) fixation with modified Yamane's double-needle technique and flanged haptics. Methods: This was a prospective interventional study that enrolled 31 consecutive patients undergoing SFIOL with the modified Yamane's technique. All patients underwent comprehensive evaluation including uncorrected and best-corrected vision, intraocular pressure, ultrasound biomicroscopy, endothelial cell density, and macular thickness using optical coherence tomography (OCT). We excluded patients with visually significant coexistent pathology such as corneal scars, macular pathology, and glaucoma. Results: The mean age of subjects was 57 +/- 16.9 years and 23 were men (74%). Surgery was performed for aphakia following complicated cataract surgery in 10 eyes (32%), with lensectomy for subluxated/dislocated cataract in 6 eyes (19%), and with IOL explantation for subluxated/dislocated IOL in 15 eyes (48%). There were no intraoperative complications. Uncorrected visual acuity improved from median of 1.48 logarithm of minimum angle of resolution (logMAR) units (interquartile range [IQR] = 1.3-2 logMAR) at baseline to 0.3 logMAR (IQR = 0.2-0.4 logMAR) at 6 weeks (P < 0.001) which was maintained at 6 months. There were no significant changes in endothelial cell density (P = 0.34) and OCT-based macular thickness (P = 0.31) at 6 months. Two eyes had slight IOL decentration. Conclusion: Our initial experience suggests that the Yamane's technique for SFIOL is a simple procedure with a short-learning curve and is independent of scleral flaps, tunnels, sutures, and fibrin glue. Using widely available 27-gauge needle instead of 30-gauge thin wall needle as originally described by Yamane makes it possible for the use of various three-piece IOLs available globally. Further studies are required for widespread acceptance of this technique.
引用
收藏
页码:1450 / 1453
页数:4
相关论文
共 50 条
  • [21] Transconjunctival Sutureless Intrascleral Fixation of Secondary Intraocular Lenses in Patients with Uveitis
    Todorich, Bozho
    Thanos, Aristomenis
    Yonekawa, Yoshihiro
    Thomas, Benjamin J.
    Abbey, Ashkan M.
    Faia, Lisa J.
    OCULAR IMMUNOLOGY AND INFLAMMATION, 2018, 26 (03) : 456 - 460
  • [22] Management of complications of sutureless intrascleral intraocular lens fixation
    Cheng, Chia-Yi
    Chou, Yu-Bai
    Tsai, Chia-Ying
    Hsieh, Ming-Hung
    Hsiao, Chia-Chieh
    Lai, Tso-Ting
    TAIWAN JOURNAL OF OPHTHALMOLOGY, 2024, 14 (01) : 95 - 101
  • [23] Sutureless Intrascleral Intraocular Lens Fixation Using a Microtube-Assisted Technique
    Yuda, Kentaro
    Shimizu, Toshiki
    Hayashi, Takahiko
    Yuda, Kenji
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2019, 39 : 39 - 43
  • [24] Sutureless Intrascleral Intraocular Lens Fixation Using a Microtube-assisted Technique
    Yuda, Kentaro
    Shimizu, Toshiki
    Hayashi, Takahiko
    Yuda, Kenji
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [25] Sutureless intrascleral posterior chamber intraocular lens fixation
    Karadag, Remzi
    Bayramlar, Huseyin
    Sari, Unsal
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (05): : 853 - 854
  • [26] Sutureless intrascleral posterior chamber intraocular lens fixation
    Gabor, Scharioth G. B.
    Pavlidis, Mitrofanis M.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (11): : 1851 - 1854
  • [27] Surgical Technique for Sutureless Intrascleral Fixation of a 3-Piece Intraocular Lens Using a 30-Gauge Needle
    Bonnell, Alyssa C.
    Mantopoulos, Dimosthenis
    Wheatley, H. Matthew
    Prenner, Jonathan L.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2019, 39 : 13 - 15
  • [28] 27-GAUGE SUTURELESS INTRASCLERAL FIXATION OF INTRAOCULAR LENSES WITH HAPTIC FLANGING Short-Term Clinical Outcomes and a Disinsertion Force Study
    Stem, Maxwell S.
    Wa, Christianne A.
    Todorich, Bozho
    Woodward, Maria A.
    Walsh, Mark K.
    Wolfe, Jeremy D.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2019, 39 (11): : 2149 - 2154
  • [29] Combined Femtosecond Laser-Assisted Cataract Surgery and 27-Gauge Transconjunctival Sutureless Vitrectomy
    Yilmaz, Sami
    Avci, Remzi
    Yildiz, Aysegul Mavi
    JOURNAL OF OPHTHALMOLOGY, 2020, 2020
  • [30] Outcomes of transconjunctival sutureless 27-gauge vitrectomy with silicone oil infusion
    Okan Toygar
    Cindy W. Mi
    Daniel M. Miller
    Christopher D. Riemann
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2016, 254 : 2111 - 2118