Toward a Patient-Specific Traceable Quantification of SPECT/CT-Based Radiopharmaceutical Distributions

被引:3
|
作者
Theisen, Anna-Lena [1 ]
Lassmann, Michael [1 ]
Tran-Gia, Johannes [1 ]
机构
[1] Univ Wurzburg, Dept Nucl Med, Wurzburg, Germany
关键词
methods; SPECT/CT; 3D printing; activity distribution; kidney phantom; quantitative SPECT/CT; RADIONUCLIDE THERAPY; RENAL TOXICITY; KIDNEY; DOSIMETRY; ACCURACY; PHANTOMS;
D O I
10.2967/jnumed.121.262925
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Quantitative SPECT/CT imaging is currently the state of the art for peritherapeutic monitoring of radiopharmaceutical distributions. Because of poor resolution, however, the verification of SPECT/CT-based activity distributions is of particular importance. Because of the lack of a ground truth in patient measurements, phantoms are commonly used as a substitute for clinical validation of quantitative SPECT/CT. Because of the time-consuming and erroneous preparation of multicompartment phantoms, such as for the kidney, the usually very complex internal activity distributions are typically replaced by 1- or 2-compartment models. To provide a simplified solution for generating inhomogeneous activity distributions, this work presents a methodology for designing single-compartment phantoms thatmimic inhomogeneous spatial activity distributions by using internal filling structures of different volume fractions. Methods: A series of phantoms with different filling structures was designed, 3-dimensionally printed, and measured. After assessing the feasibility of the presented approach in a simple geometry, a set of three patient-specific kidney phantoms was designed on the basis of the contrast-enhanced CT scan of a patient with metastatic castration-resistant prostate cancer. Internal gyroid structures of different wall thicknesses were used in the renal medulla and cortex to reproduce the inhomogeneous activity distribution observed in a peritherapeutic SPECT/CT acquisition 24 h after injection of Lu-177-labeled prostate-specific membrane antigen (apparent activity concentration ratios of 1:1, 1:3.5, and 1:7.5). After 3-dimensional printing, SPECT/CT experiments were performed and the results were compared with the patient data for different reconstruction settings (iterations, subsets, and postfiltering). Results: Good agreement was found between phantom designs and fabricated phantoms (based on high-resolution CT). No internal filling structures were visible in any of the SPECT images, indicating a sufficiently small feature size. Although good visual and quantitative agreement was achieved for certain combinations of filling structure and reconstruction, a histogram analysis indicated an even more complex activity distribution in the patient than represented by the two compartments assumed in our model. Conclusion: The proposed methodology provides patient-specific phantoms mimicking inhomogeneous activity distributions while using a single stock solution, thus simplifying the filling process and reducing uncertainties in the activity determination. This method enables an unprecedented possibility for patient-specific evaluation of radiopharmaceutical uptake, reducing uncertainties in internal dosimetry and individualized treatments.
引用
收藏
页码:1108 / 1116
页数:9
相关论文
共 50 条
  • [41] Patient-specific SPECT imaging protocols to standardize image noise
    Sarah G. Cuddy-Walsh
    Duncan C. Clackdoyle
    Jennifer M. Renaud
    R. Glenn Wells
    Journal of Nuclear Cardiology, 2021, 28 : 225 - 233
  • [42] Osteotomies around the knee: preoperative planning using CT-based three-dimensional analysis, patient-specific cutting and reduction guides
    Vlachopoulos, Lazaros
    Fucentese, Sandro F.
    OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2023, 35 (05): : 225 - 238
  • [43] TOWARD CT-BASED FACIAL FRACTURE TREATMENT
    HEMMY, DC
    PLASTIC AND RECONSTRUCTIVE SURGERY, 1990, 85 (02) : 213 - 214
  • [44] Patient-specific SPECT imaging protocols to standardize image noise
    Cuddy-Walsh, Sarah G.
    Clackdoyle, Duncan C.
    Renaud, Jennifer M.
    Wells, R. Glenn
    JOURNAL OF NUCLEAR CARDIOLOGY, 2021, 28 (01) : 225 - 233
  • [45] Toward a patient-specific tissue engineered vascular graft
    Best, Cameron
    Strouse, Robert
    Hor, Kan
    Pepper, Victoria
    Tipton, Amy
    Kelly, John
    Shinoka, Toshiharu
    Breuer, Christopher
    JOURNAL OF TISSUE ENGINEERING, 2018, 9
  • [46] Validation of Computational Fluid Dynamics in CT-based Airway Models with SPECT/CT
    De Backer, Jan W.
    Vos, Wim G.
    Vinchurkar, Samir C.
    Claes, Rita
    Drollmann, Anton
    Wulfrank, Denis
    Parizel, Paul M.
    Germonpre, Paul
    De Backer, Wilfried
    RADIOLOGY, 2010, 257 (03) : 854 - 862
  • [47] Interpretation of myocardial perfusion SPECT with CT-based attenuation correction
    Ansheles, A.
    Martirosyan, L.
    Sergienko, I.
    Sergienko, V.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S527 - S528
  • [48] Rotational alignment of the distal femur: anthropometric measurements with CT-based patient-specific instruments planning show high variability of the posterior condylar angle
    Thienpont, Emmanuel
    Schwab, Pierre-Emmanuel
    Paternostre, Frederic
    Koch, Peter
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (12) : 2995 - 3002
  • [49] Significant differences between manufacturer and surgeon in the accuracy of final component size prediction with CT-based patient-specific instrumentation for total knee arthroplasty
    Cucchi, Davide
    Menon, Alessandra
    Compagnoni, Riccardo
    Ferrua, Paolo
    Fossati, Chiara
    Randelli, Pietro
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2018, 26 (11) : 3317 - 3324
  • [50] CT-based patient-specific instrumentation for total knee arthroplasty in over 700 cases: single-use instruments are as accurate as standard instruments
    Stefan Gaukel
    Raphael N. Vuille-dit-Bille
    Michel Schläppi
    Peter P. Koch
    Knee Surgery, Sports Traumatology, Arthroscopy, 2022, 30 : 447 - 455