Toward a Patient-Specific Traceable Quantification of SPECT/CT-Based Radiopharmaceutical Distributions

被引:3
|
作者
Theisen, Anna-Lena [1 ]
Lassmann, Michael [1 ]
Tran-Gia, Johannes [1 ]
机构
[1] Univ Wurzburg, Dept Nucl Med, Wurzburg, Germany
关键词
methods; SPECT/CT; 3D printing; activity distribution; kidney phantom; quantitative SPECT/CT; RADIONUCLIDE THERAPY; RENAL TOXICITY; KIDNEY; DOSIMETRY; ACCURACY; PHANTOMS;
D O I
10.2967/jnumed.121.262925
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Quantitative SPECT/CT imaging is currently the state of the art for peritherapeutic monitoring of radiopharmaceutical distributions. Because of poor resolution, however, the verification of SPECT/CT-based activity distributions is of particular importance. Because of the lack of a ground truth in patient measurements, phantoms are commonly used as a substitute for clinical validation of quantitative SPECT/CT. Because of the time-consuming and erroneous preparation of multicompartment phantoms, such as for the kidney, the usually very complex internal activity distributions are typically replaced by 1- or 2-compartment models. To provide a simplified solution for generating inhomogeneous activity distributions, this work presents a methodology for designing single-compartment phantoms thatmimic inhomogeneous spatial activity distributions by using internal filling structures of different volume fractions. Methods: A series of phantoms with different filling structures was designed, 3-dimensionally printed, and measured. After assessing the feasibility of the presented approach in a simple geometry, a set of three patient-specific kidney phantoms was designed on the basis of the contrast-enhanced CT scan of a patient with metastatic castration-resistant prostate cancer. Internal gyroid structures of different wall thicknesses were used in the renal medulla and cortex to reproduce the inhomogeneous activity distribution observed in a peritherapeutic SPECT/CT acquisition 24 h after injection of Lu-177-labeled prostate-specific membrane antigen (apparent activity concentration ratios of 1:1, 1:3.5, and 1:7.5). After 3-dimensional printing, SPECT/CT experiments were performed and the results were compared with the patient data for different reconstruction settings (iterations, subsets, and postfiltering). Results: Good agreement was found between phantom designs and fabricated phantoms (based on high-resolution CT). No internal filling structures were visible in any of the SPECT images, indicating a sufficiently small feature size. Although good visual and quantitative agreement was achieved for certain combinations of filling structure and reconstruction, a histogram analysis indicated an even more complex activity distribution in the patient than represented by the two compartments assumed in our model. Conclusion: The proposed methodology provides patient-specific phantoms mimicking inhomogeneous activity distributions while using a single stock solution, thus simplifying the filling process and reducing uncertainties in the activity determination. This method enables an unprecedented possibility for patient-specific evaluation of radiopharmaceutical uptake, reducing uncertainties in internal dosimetry and individualized treatments.
引用
收藏
页码:1108 / 1116
页数:9
相关论文
共 50 条
  • [21] RMDP:: A dedicated package for 131I SPECT quantification, registration and patient-specific dosimetry
    Guy, MJ
    Flux, GD
    Papavasileiou, P
    Flower, MA
    Ott, RJ
    CANCER BIOTHERAPY AND RADIOPHARMACEUTICALS, 2003, 18 (01) : 61 - 69
  • [22] INTRA-VOXEL MICRO-ELASTO-PLASTICITY FOR CT-BASED PATIENT-SPECIFIC FRACTURE RISK ASSESSMENT OF VERTEBRAE
    Blanchard, R.
    Morin, C.
    Vella, A.
    Sant, Z.
    Hellmich, Ch.
    ENGINEERING MECHANICS 2014, 2014, : 92 - 95
  • [23] Patient-specific CT-based 3D passive FSI model for left ventricle in hypertrophic obstructive cardiomyopathy
    Deng, Long
    Huang, Xueying
    Yang, Chun
    Song, Yunhu
    Tang, Dalin
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2018, 21 (03) : 255 - 263
  • [24] Accuracy of MRI-basedvs. CT-based patient-specific instrumentation in total knee arthroplasty: A meta-analysis
    An, Vincent V. G.
    Sivakumar, Brahman S.
    Phan, Kevin
    Levy, Yadin David
    Bruce, Warwick J. M.
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2017, 22 (01) : 116 - 120
  • [25] Three-dimensional accuracy of high tibial osteotomy using two generations of CT-based patient-specific guides
    Meier, Patrick
    Aichmair, Alexander
    Kochli, Gian Luca
    Vlachopoulos, Lazaros
    Furnstahl, Philipp
    Fucentese, Sandro F.
    SWISS MEDICAL WEEKLY, 2017, 147 : 57S - 57S
  • [26] Dosimetric Study of Cone-Beam CT-Based Radiation Treatment Planning Using a Patient-Specific Stepwise CT-Density Table
    Chen, S.
    Le, Q.
    Mutaf, Y.
    Yi, B.
    D'Souza, W.
    MEDICAL PHYSICS, 2015, 42 (06) : 3280 - 3280
  • [27] CT-based radiomics and machine learning for the prediction of myocardial ischemia: Toward increasing quantification
    Lin, Andrew
    Dey, Damini
    JOURNAL OF NUCLEAR CARDIOLOGY, 2022, 29 (01) : 275 - 277
  • [28] CT-based radiomics and machine learning for the prediction of myocardial ischemia: Toward increasing quantification
    Andrew Lin
    Damini Dey
    Journal of Nuclear Cardiology, 2022, 29 : 275 - 277
  • [29] Patient-Specific Phantoms for Tc-99m Brain Perfusion Imaging with SPECT/CT
    Grings, A.
    Reymann, M.
    Vija, A. H.
    Kuwert, T.
    Ritt, P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (SUPPL 1) : S482 - S483
  • [30] A Multi-Planar CT-Based Comparative Analysis of Patient-Specific Cutting Guides With Conventional Instrumentation in Total Knee Arthroplasty
    Marimuthu, Kanniraj
    Chen, Darren B.
    Harris, Ian A.
    Wheatley, Emma
    Bryant, Carl J.
    MacDessi, Samuel J.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (06): : 1138 - 1142