Two-Point Frequency Shift Method for Shear Wave Attenuation Measurement

被引:28
|
作者
Kijanka, Piotr [1 ,2 ]
Urban, Matthew W. [1 ,3 ]
机构
[1] Mayo Clin, Dept Radiol, Rochester, MN 55905 USA
[2] AGH Univ Sci & Technol, Dept Robot & Mechatron, PL-30059 Krakow, Poland
[3] Mayo Clin, Dept Physiol & Biomed Engn, Rochester, MN 55905 USA
基金
美国国家卫生研究院;
关键词
Attenuation; Attenuation measurement; Frequency measurement; Shape; Biomedical measurement; Elastography; Phantoms; Acoustic radiation force (ARF); attenuation; attenuation measuring ultrasound shear wave elastography (AMUSE); frequency shift (FS); full-width at half-maximum (FWHM); phantom; shear wave elastography (SWE); soft tissue; ultrasound; viscoelastic; VISCOELASTIC PROPERTIES; TISSUE ELASTICITY; RADIATION FORCE; ELASTOGRAPHY; PROPAGATION; VISCOSITY; QUANTIFICATION; STEATOSIS; FIBROSIS;
D O I
10.1109/TUFFC.2019.2945620
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Ultrasound shear wave elastography (SWE) is an increasingly used noninvasive modality for quantitative evaluation of tissue mechanical properties. SWE typically uses an acoustic radiation force to produce laterally propagating shear waves that are tracked in the spatial and temporal domains, in order to obtain the wave velocity. One of the ways to study the viscoelasticity is through studying the shear wave phase velocity dispersion curves. Shear wave attenuation can be also characterized in viscoelastic tissues with methods that use multiple lateral data samples. In this article, we present an alternative method for measuring the shear wave attenuation without using a rheological model two-point frequency shift (2P-FS). The technique uses information related to the amplitude spectra FS of shear waves measured at only two lateral locations. The theoretical basis for the 2P-FS is derived and validated. We examined how the first signal position and the distance between the two locations affect the shear wave attenuation estimation in the 2P-FS method. We tested this new method on digital phantom data created using the local interaction simulation approach (LISA) in viscoelastic media. Moreover, we tested data acquired from custom-made tissue-mimicking viscoelastic phantom experiments and ex vivo porcine liver measurements. We compared results from the 2P-FS method with the other two techniques used for assessing a shear wave attenuation: the FS-based method and the attenuation-measuring ultrasound shear wave elastography (AMUSE) technique. In addition, we evaluated the 2P-FS algorithm with different levels of added white Gaussian noise to the shear wave particle velocity using numerical phantoms. Tests conducted showed that the 2P-FS method gives robust results based on only two measurements and can be used to measure attenuation of viscoelastic soft tissues.
引用
收藏
页码:483 / 496
页数:14
相关论文
共 50 条
  • [31] Research on measurement method of wind turbine tower inclination based on two-point measuring station
    Liao J.
    Lyu W.
    Lu B.
    Yao S.
    Zhou Z.
    Zhong X.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2021, 42 (12): : 126 - 133
  • [32] From two-point closures of isotropic turbulence to LES of shear flows
    Lesieur, M
    Comte, P
    Dubief, Y
    Lamballais, E
    Métais, O
    Ossia, S
    FLOW TURBULENCE AND COMBUSTION, 2000, 63 (1-4) : 247 - 267
  • [33] Two-point linearization method for the analysis of pipe networks
    van Zyl, Jakobus E.
    Kumar, Prabhat
    Gupta, Mayank
    JOURNAL OF HYDRAULIC ENGINEERING, 2008, 134 (08) : 1176 - 1179
  • [34] Effect of misspecification of gene frequency on the two-point LOD score
    Pal, DK
    Durner, M
    Greenberg, DA
    EUROPEAN JOURNAL OF HUMAN GENETICS, 2001, 9 (11) : 855 - 859
  • [36] Effect of misspecification of gene frequency on the two-point LOD score
    Deb K Pal
    Martina Durner
    David A Greenberg
    European Journal of Human Genetics, 2001, 9 : 855 - 859
  • [37] Novel method for solving singular two-point BVPs
    Bataineh, A. Sami
    INTERNATIONAL CONFERENCE ON ADVANCEMENT IN SCIENCE AND TECHNOLOGY 2012 (ICAST): CONTEMPORARY MATHEMATICS, MATHEMATICAL PHYSICS AND THEIR APPLICATIONS, 2013, 435
  • [38] A fast two-point method for gas adsorption measurements
    Poulis, JA
    Massen, CH
    Robens, E
    Unger, KK
    CHARACTERIZATION OF POROUS SOLIDS V, 2000, 128 : 151 - 154
  • [39] A multiscale two-point flux-approximation method
    Moyner, Olav
    Lie, Knut-Andreas
    JOURNAL OF COMPUTATIONAL PHYSICS, 2014, 275 : 273 - 293
  • [40] Two-point Dixon Method With Flexible Echo Times
    Berglund, Johan
    Ahlstroem, Hakan
    Johansson, Lars
    Kullberg, Joel
    MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (04) : 994 - 1004