A national dosimetric audit of IMRT

被引:53
|
作者
Budgell, Geoff [1 ]
Berresford, Joe [1 ]
Trainer, Michael [1 ]
Bradshaw, Ellie [1 ]
Sharpe, Peter [2 ]
Williams, Peter [1 ]
机构
[1] Christie NHS Fdn Trust, Manchester M20 4BX, Lancs, England
[2] Natl Phys Lab, Middlesex, England
关键词
IMRT; Audit; Dosimetry; Alanine; Film; Verification; UK RADIOTHERAPY CENTERS; QUANTITATIVE-EVALUATION; DOSE DISTRIBUTIONS; CLINICAL-TRIALS; NECK-CANCER; PHANTOM; BEAMS; HEAD;
D O I
10.1016/j.radonc.2011.03.016
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: A dosimetric audit of IMRT has been carried out within the UK between June 2009 and March 2010 in order to provide an independent check of safe implementation and to identify problems in the modelling and delivery of IMRT. Methods and materials: A mail based audit involving film and alanine dosimeters was utilized. Measurements were made for each individual field in an IMRT plan isocentrically in a flat water-equivalent phantom at a depth of 5 cm. The films and alanine dosimeters were processed and analysed centrally; additional ion chamber measurements were made by each participating centre. Results: 57 of 62 centres participated, with a total of 78 plans submitted. For the film measurements, all 176 fields from the less complex IMRT plans (including prostate and breast plans) achieved over 95% pixels passing a gamma criterion of 3%/3 mm within the 20% isodose. For the more complex IMRT plans (mainly head and neck) 8/245 fields (3.3%) achieved less than 95% pixels passing a 4%/4 mm gamma criterion. Of the alanine measurements, 4/78 (5.1%) of the measurements differed by >5% from the dose predicted by the treatment planning system. Three of these were large deviations of -77.1%, -29.1% and 14.1% respectively. Excluding the three measurements outside 10%, the mean difference was 0.05% with a standard deviation of 1.5%. The out of tolerance results have been subjected to further investigations. Conclusions: A dosimetric audit has been successfully carried out of IMRT implementation by over 90% of UK radiotherapy departments. The audit shows that modelling and delivery of IMRT is accurate, suggesting that the implementation of IMRT has been carried out safely. (C) 2011 Elsevier Ireland Ltd. All rights reserved. Radiotherapy and Oncology 99 (2011) 246-252
引用
收藏
页码:246 / 252
页数:7
相关论文
共 50 条
  • [1] IMRT national audit in Portugal
    Santos, Tania
    Lopes, Maria do Carmo
    Gershkevitsh, Eduard
    Vinagre, Filipa
    Faria, David
    Carita, Liliana
    Pontes, Miguel
    Vieira, Sandra
    Poli, Esmeralda
    Faustino, Sofia
    Ribeiro, Filipa
    Trindade, Mauro
    Ponte, Fernanda
    Marcelino, Carlos
    Batista, Claudio
    Oliveira, Susana
    Figueira, Rita
    Lencart, Joana
    Diaz, Ester Gallego
    Jacob, Katia
    Bras, Sandra
    Pirraco, Rui
    Izewska, Joanna
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 65 : 128 - 136
  • [2] A national QA audit for IMRT and VMAT
    Seravalli, E.
    Houweling, A. C.
    Van Gellekom, M. P. R.
    Kaas, J.
    Kuik, M.
    Loeff, E.
    Raaben, T. A.
    De Pooter, J. A.
    De Vries, J. H. W.
    Van de Kamer, J. B.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S852 - S853
  • [3] Testing the methodology for a dosimetric end-to-end audit of IMRT/VMAT: results of IAEA multicentre and national studies
    Wesolowska, Paulina
    Georg, Dietmar
    Lechner, Wolfgang
    Kazantsev, Pavel
    Bokulic, Tomislav
    Tedgren, Asa Carlsson
    Adolfsson, Emelie
    Campos, Anna Maria
    Leandro Alves, Victor Gabriel
    Luo Suming
    Hao, Wu
    Ekendahl, Daniela
    Koniarova, Irena
    Bulski, Wojciech
    Chelminski, Krzysztof
    Alonso Samper, Jose Luis
    Vinatha, Sumanth Panyam
    Rakshit, Sougata
    Siri, Srimanoroth
    Tomsejm, Milan
    Tenhunen, Mikko
    Povall, Julie
    Kry, Stephen F.
    Followill, David S.
    Thwaites, David I.
    Izewska, Joanna
    ACTA ONCOLOGICA, 2019, 58 (12) : 1731 - 1739
  • [4] DEVELOPMENT OF NATIONAL RADIOTHERAPY IMRT AUDIT IN THE UK
    Bolton, S.
    Budgell, G.
    Bradshaw, E.
    Trainer, M.
    Berresford, J.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S25 - S26
  • [5] Results of a national audit of IMRT and VMAT patient QA
    Seravalli, E.
    Houweling, A. C.
    Van Gellekom, M. P. R.
    Kaas, J.
    Kuik, M.
    Loeff, E. A.
    Raaben, T. A.
    De Pooter, J. A.
    De Vries, J. H. W.
    Van de Kamer, J. B.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S259 - S260
  • [6] How much does experience add to IMRT planning? Results of an external dosimetric audit of IMRT for adjuvant chemoradiation for gastric cancer
    Chung, H. T.
    Lee, B.
    Park-Somers, E.
    Lu, J. J.
    Xia, P.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S66 - S66
  • [7] IAEA supported national 'end-to-end' IMRT audit in Portugal
    Santos, T.
    Lopes, M. D. C.
    Gershkevitsh, E.
    Izewska, J.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S320 - S320
  • [8] How much does experience add to IMRT planning? Final results of an external dosimetric audit of IMRT for adjuvant chemoradiation for gastric cancer
    Chung, H. T.
    Lee, B.
    Park-Somers, E.
    Lu, J. J.
    Xia, P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S286 - S287
  • [9] Dosimetric verification of radiotherapy treatment planning systems in Serbia: national audit
    Laza Rutonjski
    Borislava Petrović
    Milutin Baucal
    Milan Teodorović
    Ozren Čudić
    Eduard Gershkevitsh
    Joanna Izewska
    Radiation Oncology, 7
  • [10] Dosimetric verification of radiotherapy treatment planning systems in Serbia: national audit
    Rutonjski, Laza
    Petrovic, Borislava
    Baucal, Milutin
    Teodorovic, Milan
    Cudic, Ozren
    Gershkevitsh, Eduard
    Izewska, Joanna
    RADIATION ONCOLOGY, 2012, 7