A Comparison of 2D and 3D Edge Detectors in Semi Automated Measurements of Chamber Volumes Using 3D Echocardiographic Laboratory Phantom Images

被引:0
|
作者
Wang, K. [1 ]
Sims, A. J. [1 ]
Murray, A. [1 ]
机构
[1] Newcastle Univ, Newcastle Upon Tyne NE1 7RU, Tyne & Wear, England
来源
CINC: 2009 36TH ANNUAL COMPUTERS IN CARDIOLOGY CONFERENCE | 2009年 / 36卷
关键词
3-DIMENSIONAL ECHOCARDIOGRAPHY; MYOCARDIAL-INFARCTION; HEART-FAILURE;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Chamber volume measurement is fundamental for assessing many indices of cardiac function. 3D echocardiography offers great potential for accurate measurement, but many automated or semi-automated techniques suffer from acoustic noise and artefact, which can be reduced by suitable choice of edge detectors. We compared the effects of 2D and 3D first order derivative edge detectors with similar size on accuracy and repeatability in six volume measurement methods of 3D echo images of a laboratory balloon phantom. Overall accuracy compared with known volumes was better for 3D (-1.0ml; -4.0ml to 2.0ml 95% CI; P=0.53) than 2D (-11.6ml; -14.8ml to -8.5ml 95% CI; P<0.001). Repeatability was better for 3D (SD=0.9ml) than 2D (SD=1.5ml) with difference in coefficient of variation of 0.6 (P<0.001). 3D operators show potential for better performance with 3D echo images.
引用
收藏
页码:1 / 4
页数:4
相关论文
共 50 条
  • [31] 3D surface reconstruction from multiview photographic images using 2D edge contours
    Prakoonwit, Simant
    Benjamin, Ralph
    3D RESEARCH, 2012, 3 (04):
  • [32] Comparison of 2D and 3D gamma analyses
    Pulliam, Kiley B.
    Huang, Jessie Y.
    Howell, Rebecca M.
    Followill, David
    Bosca, Ryan
    O'Daniel, Jennifer
    Kry, Stephen F.
    MEDICAL PHYSICS, 2014, 41 (02) : 021710
  • [33] 3D triangular mesh matching through a sequence of registered 2D and 3D images
    Dion, D
    Laurendeau, D
    Borgeat, L
    15TH INTERNATIONAL CONFERENCE ON PATTERN RECOGNITION, VOL 1, PROCEEDINGS: COMPUTER VISION AND IMAGE ANALYSIS, 2000, : 977 - 980
  • [34] Registration of 2D Histological Images of Bone Implants with 3D SRμCT Volumes
    Sarve, Hamid
    Lindblad, Joakim
    Johansson, Carina B.
    ADVANCES IN VISUAL COMPUTING, PT I, PROCEEDINGS, 2008, 5358 : 1071 - +
  • [35] AUTOMATED 2D/3D REGISTRATION FOR LUNG BRACHYTHERAPY
    Zvonarev, P.
    Farrell, T.
    Hunter, R.
    Hayward, J.
    Wierzbicki, M.
    Sur, R.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S479 - S479
  • [36] An approach to 2D/3D registration of a vertebra in 2D x-ray fluoroscopies with 3D CT images
    Weese, J
    Buzug, TM
    Lorenz, C
    Fassnacht, C
    CVRMED-MRCAS'97: FIRST JOINT CONFERENCE - COMPUTER VISION, VIRTUAL REALITY AND ROBOTICS IN MEDICINE AND MEDICAL ROBOTICS AND COMPUTER-ASSISTED SURGERY, 1997, 1205 : 119 - 128
  • [37] Automated Conversion of 2D to 3D Image using Manifold Learning
    Chahal, Nidhi
    Pippal, Meghna
    Chaudhury, Santanu
    2015 FIFTH NATIONAL CONFERENCE ON COMPUTER VISION, PATTERN RECOGNITION, IMAGE PROCESSING AND GRAPHICS (NCVPRIPG), 2015,
  • [38] Pixel Coordinates for Obtaining 3D Body Measurements from 2D Images
    Sengoz, Nefise Gonul
    Zeybek, Fatih
    TEKSTIL VE KONFEKSIYON, 2024, 34 (02): : 127 - 146
  • [39] HIERARCHICAL REPRESENTATIONS OF 2D/3D GRAY-SCALE IMAGES AND THEIR 2D/3D 2-WAY CONVERSION
    MAO, XY
    KUNII, TL
    FUJISHIRO, I
    NOMA, T
    IEEE COMPUTER GRAPHICS AND APPLICATIONS, 1987, 7 (12) : 37 - 44
  • [40] 3D object understanding from 2D images
    Wang, PSP
    INTERNATIONAL SYMPOSIUM ON MULTISPECTRAL IMAGE PROCESSING, 1998, 3545 : 33 - 43