A Comparison of 2D and 3D Edge Detectors in Semi Automated Measurements of Chamber Volumes Using 3D Echocardiographic Laboratory Phantom Images

被引:0
|
作者
Wang, K. [1 ]
Sims, A. J. [1 ]
Murray, A. [1 ]
机构
[1] Newcastle Univ, Newcastle Upon Tyne NE1 7RU, Tyne & Wear, England
关键词
3-DIMENSIONAL ECHOCARDIOGRAPHY; MYOCARDIAL-INFARCTION; HEART-FAILURE;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Chamber volume measurement is fundamental for assessing many indices of cardiac function. 3D echocardiography offers great potential for accurate measurement, but many automated or semi-automated techniques suffer from acoustic noise and artefact, which can be reduced by suitable choice of edge detectors. We compared the effects of 2D and 3D first order derivative edge detectors with similar size on accuracy and repeatability in six volume measurement methods of 3D echo images of a laboratory balloon phantom. Overall accuracy compared with known volumes was better for 3D (-1.0ml; -4.0ml to 2.0ml 95% CI; P=0.53) than 2D (-11.6ml; -14.8ml to -8.5ml 95% CI; P<0.001). Repeatability was better for 3D (SD=0.9ml) than 2D (SD=1.5ml) with difference in coefficient of variation of 0.6 (P<0.001). 3D operators show potential for better performance with 3D echo images.
引用
收藏
页码:1 / 4
页数:4
相关论文
共 50 条
  • [11] 3D Anisotropic Hybrid Network: Transferring Convolutional Features from 2D Images to 3D Anisotropic Volumes
    Liu, Siqi
    Xu, Daguang
    Zhou, S. Kevin
    Pauly, Olivier
    Grbic, Sasa
    Mertelmeier, Thomas
    Wicklein, Julia
    Jerebko, Anna
    Cai, Weidong
    Comaniciu, Dorin
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2018, PT II, 2018, 11071 : 851 - 858
  • [12] Registration of 2D cardiac images to real-time 3D ultrasound volumes for 3D stress echocardiography
    Leung, K. Y. Esther
    Van Stralen, Marijn
    Voormolen, Marco M.
    Van Burken, Gerard
    Nemes, Attila
    Ten Cate, Folkert J.
    Geleijnse, Marcel L.
    De Jong, Nico
    Van der Steen, Antonius F. W.
    Reiber, Johan H. C.
    Bosch, Johan G.
    MEDICAL IMAGING 2006: IMAGE PROCESSING, PTS 1-3, 2006, 6144
  • [13] Fluoroscopic 3D Images Based on 2D Treatment Images Using a Realistic Modified XCAT Phantom
    Lewis, J.
    Li, R.
    St James, S.
    Yue, Y.
    Berbeco, R.
    Mishra, P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S737 - S737
  • [14] Accuracy of an automated transthoracic echocardiographic tool for 3D assessment of left heart chamber volumes
    Spitzer, Ernest
    Ren, Ben
    Soliman, Osama I. I.
    Zijlstra, Felix
    Van Mieghem, Nicolas M.
    Geleijnse, Marcel L.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2017, 34 (02): : 199 - 209
  • [15] A comparison of 2D and 3D PIV measurements in an oblique jet
    M. Abe
    E. K. Longmire
    K. Hishida
    M. Maeda
    Journal of Visualization, 2000, 3 (2) : 165 - 173
  • [16] 2D and 3D separation of stresses using automated photoelasticity
    Haake, SJ
    Patterson, EA
    Wang, ZF
    EXPERIMENTAL MECHANICS, 1996, 36 (03) : 269 - 276
  • [17] Reinventing 2D Convolutions for 3D Images
    Yang, Jiancheng
    Huang, Xiaoyang
    He, Yi
    Xu, Jingwei
    Yang, Canqian
    Xu, Guozheng
    Ni, Bingbing
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2021, 25 (08) : 3009 - 3018
  • [18] 3D and 2D/3D holograms model
    A. A. Boriskevich
    V. K. Erohovets
    V. V. Tkachenko
    Optical Memory and Neural Networks, 2012, 21 (4) : 242 - 248
  • [19] Using specularities in comparing 3D models and 2D images
    Osadchy, Margarita
    Jacobs, David
    Ramamoorthi, Ravi
    Tucker, David
    COMPUTER VISION AND IMAGE UNDERSTANDING, 2008, 111 (03) : 275 - 294
  • [20] Evaluation of the Rotational Alignment Accuracy and Error Using 3D/3D, 2D/3D and 3D Surface Registration
    Kuo, H.
    Ballangrud, A.
    Li, G.
    Lovelock, D.
    Wolthuis, B.
    Della-Biancia, C.
    Berry, S.
    Hunt, M.
    MEDICAL PHYSICS, 2019, 46 (06) : E307 - E308