Endourological Training Using 3D-Printed Bladder Phantoms: Development and Prospective Evaluation

被引:9
|
作者
Waldbillig, Frank [1 ,2 ]
von Rohr, Lennard [1 ]
Nientiedt, Malin [1 ]
Gruene, Britta [1 ,2 ]
Hein, Simon [2 ,3 ]
Suarez-Ibarrola, Rodrigo [2 ,3 ]
Miernik, Arkadiusz [2 ,3 ]
Ritter, Manuel [2 ,4 ]
Kriegmair, Maximilian C. [1 ,2 ]
机构
[1] Heidelberg Univ, Univ Med Ctr Mannheim, Dept Urol & Urosurg, Theodor Kutzer Ufer 1-3, D-68167 Mannheim, Germany
[2] German Fed Minist Educ & Res BMBF, RaVeNNA 4pi Consortium, Mannheim, Germany
[3] Univ Freiburg, Med Ctr, Fac Med, Dept Urol, Freiburg, Germany
[4] Univ Bonn, Univ Med Ctr Bonn, Dept Urol & Pediat Urol, Bonn, Germany
关键词
cystoscopy; endoscopy; surgical training; education; urology; simulator;
D O I
10.1089/end.2020.0900
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background: To create and evaluate a realistic, anatomically accurate, and user-friendly bladder phantom for reproducible endourological training purposes and endoscope mastery. Materials and Methods: The anatomy of full bladders was mapped from human computed tomography datasets. After a 3D model development process, content evidence and response process evidence (RPE) of the phantom were evaluated using the system usability scale (SUS), 5-point Likert scale questionnaires, and task execution of experienced urologists (U) and endoscopy-naive medical students (MS) in two training sessions (first vs second). Required validation cohort sizes (1:10) of the evaluating urologists (n = 12) and students (n = 115) were precalculated. Time measurements were recorded. Students were additionally evaluated by a validated global psychomotor assessment score (GPSS). Group comparisons were calculated by the Mann-Whitney U test. All tests were two sided with p < 0.05 considered statistically significant. Results: Content evidence was assessed by urologists with an "excellent" SUS score of 89.4 +/- 5.9 and an average "agreement" of >= 4 pts in the Likert scale questionnaires. RPE was assessed by intra- and intergroup time comparison for the execution of endoscopic tasks (cystoscopy [CY], guidewire insertion, and tumor biopsy). For CY, U: first 17.6 +/- 4.4 seconds vs second 12.4 +/- 2.0 seconds, p = 0.002; MS: first 56.6 +/- 28.2 seconds vs second 28.6 +/- 14.7 seconds, p < 0.001; U vs MS: first U 17.6 +/- 4.4 seconds vs first MS 56.6 +/- 28.2 seconds, p < 0.001, second U 12.4 +/- 2.0 seconds vs second MS 28.6 +/- 14.7 seconds, p < 0.001. Significant time differences were documented for all tasks and sessions (p < 0.001). Additionally, significant GPSS differences were recorded between the sessions (GPSS: first 20.4 +/- 5.1 pts vs second 24.7 +/- 4.0 pts, p < 0.001). Conclusions: Our low-fidelity 3D-printed bladder, called BladCap, is an easy-to-assemble, inexpensive, and robust phantom. We present data, which establish construct validity to support use as a clinical training device.
引用
收藏
页码:1257 / 1264
页数:8
相关论文
共 50 条
  • [41] Development of a 3D-printed nuchal translucency model: a pilot study for prenatal ultrasound training
    Recker, Florian
    Remmersmann, Laura
    Jost, Elena
    Jimenez-Cruz, Jorge
    Haverkamp, Nicolas
    Gembruch, Ulrich
    Strizek, Brigitte
    Schaefer, Valentin S.
    ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 2024, 310 (04) : 2055 - 2064
  • [42] Evaluation of challenges and limitations of mechanical thrombectomy using 3D printed neurovascular phantoms
    Sommer, Kelsey N.
    Bhurwani, Mohammad Mahdi Shiraz
    Mokin, Maxim
    Ionita, Ciprian N.
    MEDICAL IMAGING 2021: IMAGING INFORMATICS FOR HEALTHCARE, RESEARCH, AND APPLICATIONS, 2021, 11601
  • [43] Design of 3D-Printed Hybrid Axial-Flux Motor Using 3D-Printed SMC Core
    Pyo, Hyun-Jo
    Jeong, Jae Won
    Yu, Jihun
    Lee, Sung Gu
    Kim, Won-Ho
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2020, 30 (04)
  • [44] Mechanical testing and comparison of porcine tissue, silicones and 3D-printed materials for cardiovascular phantoms
    Illi, Joel
    Ilic, Marc
    Stark, Anselm Walter
    Amstutz, Cornelia
    Burger, Juergen
    Zysset, Philippe
    Haeberlin, Andreas
    Grani, Christoph
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [45] 3D-Printed Tissue-Mimicking Phantoms for Medical Imaging and Computational Validation Applications
    Cloonan, Aidan J.
    Shahmirzadi, Danial
    Li, Ronny X.
    Doyle, Barry J.
    Konofagou, Elisa E.
    McGloughlin, Tim M.
    3D PRINTING AND ADDITIVE MANUFACTURING, 2014, 1 (01) : 14 - 23
  • [46] Spiral breast computed tomography (CT): signal-to-noise and dose optimization using 3D-printed phantoms
    Germann, Manon
    Shim, Sojin
    Angst, Florian
    Saltybaeva, Natalia
    Boss, Andreas
    EUROPEAN RADIOLOGY, 2021, 31 (06) : 3693 - 3702
  • [47] Investigating dose calculation accuracy around gas-filled tissue expanders using 3D-printed phantoms
    Kairn, T.
    Lathouras, M.
    Sylvander, S.
    Crowe, S.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S755 - S755
  • [48] Manufacture and Testing of Anthropomorphic 3D-printed Breast Phantoms Using a Microwave Radar Algorithm Optimized for Propagation Speed
    Herrera, D. Rodriguez
    Reimer, T.
    Nepote, M. Solis
    Pistorius, S.
    2017 11TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION (EUCAP), 2017, : 3480 - 3484
  • [49] A Quantitative Analysis of the Plastic Shell Effects in 3D-Printed Breast Phantoms for Microwave Imaging
    Reimer, Tyson
    Christie, Spencer
    Pistorius, Stephen
    2022 16TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION (EUCAP), 2022,
  • [50] Spiral breast computed tomography (CT): signal-to-noise and dose optimization using 3D-printed phantoms
    Manon Germann
    Sojin Shim
    Florian Angst
    Natalia Saltybaeva
    Andreas Boss