Endourological Training Using 3D-Printed Bladder Phantoms: Development and Prospective Evaluation

被引:9
|
作者
Waldbillig, Frank [1 ,2 ]
von Rohr, Lennard [1 ]
Nientiedt, Malin [1 ]
Gruene, Britta [1 ,2 ]
Hein, Simon [2 ,3 ]
Suarez-Ibarrola, Rodrigo [2 ,3 ]
Miernik, Arkadiusz [2 ,3 ]
Ritter, Manuel [2 ,4 ]
Kriegmair, Maximilian C. [1 ,2 ]
机构
[1] Heidelberg Univ, Univ Med Ctr Mannheim, Dept Urol & Urosurg, Theodor Kutzer Ufer 1-3, D-68167 Mannheim, Germany
[2] German Fed Minist Educ & Res BMBF, RaVeNNA 4pi Consortium, Mannheim, Germany
[3] Univ Freiburg, Med Ctr, Fac Med, Dept Urol, Freiburg, Germany
[4] Univ Bonn, Univ Med Ctr Bonn, Dept Urol & Pediat Urol, Bonn, Germany
关键词
cystoscopy; endoscopy; surgical training; education; urology; simulator;
D O I
10.1089/end.2020.0900
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background: To create and evaluate a realistic, anatomically accurate, and user-friendly bladder phantom for reproducible endourological training purposes and endoscope mastery. Materials and Methods: The anatomy of full bladders was mapped from human computed tomography datasets. After a 3D model development process, content evidence and response process evidence (RPE) of the phantom were evaluated using the system usability scale (SUS), 5-point Likert scale questionnaires, and task execution of experienced urologists (U) and endoscopy-naive medical students (MS) in two training sessions (first vs second). Required validation cohort sizes (1:10) of the evaluating urologists (n = 12) and students (n = 115) were precalculated. Time measurements were recorded. Students were additionally evaluated by a validated global psychomotor assessment score (GPSS). Group comparisons were calculated by the Mann-Whitney U test. All tests were two sided with p < 0.05 considered statistically significant. Results: Content evidence was assessed by urologists with an "excellent" SUS score of 89.4 +/- 5.9 and an average "agreement" of >= 4 pts in the Likert scale questionnaires. RPE was assessed by intra- and intergroup time comparison for the execution of endoscopic tasks (cystoscopy [CY], guidewire insertion, and tumor biopsy). For CY, U: first 17.6 +/- 4.4 seconds vs second 12.4 +/- 2.0 seconds, p = 0.002; MS: first 56.6 +/- 28.2 seconds vs second 28.6 +/- 14.7 seconds, p < 0.001; U vs MS: first U 17.6 +/- 4.4 seconds vs first MS 56.6 +/- 28.2 seconds, p < 0.001, second U 12.4 +/- 2.0 seconds vs second MS 28.6 +/- 14.7 seconds, p < 0.001. Significant time differences were documented for all tasks and sessions (p < 0.001). Additionally, significant GPSS differences were recorded between the sessions (GPSS: first 20.4 +/- 5.1 pts vs second 24.7 +/- 4.0 pts, p < 0.001). Conclusions: Our low-fidelity 3D-printed bladder, called BladCap, is an easy-to-assemble, inexpensive, and robust phantom. We present data, which establish construct validity to support use as a clinical training device.
引用
收藏
页码:1257 / 1264
页数:8
相关论文
共 50 条
  • [21] 3D-printed phantoms for characterizing SERS nanoparticle detectability in turbid media
    Fales, Andrew M.
    Strobbia, Pietro
    Vo-Dinh, Tuan
    Ilev, Ilko K.
    Pfefer, T. Joshua
    ANALYST, 2020, 145 (18) : 6045 - 6053
  • [22] Tissue-equivalence of 3D-printed plastics for medical phantoms in radiology
    Solc, J.
    Vrba, T.
    Burianova, L.
    JOURNAL OF INSTRUMENTATION, 2018, 13
  • [23] Elastically Anisotropic Phantoms Constructed from 3D-printed PLA Fibers
    Herman, Kristyna
    Torres, Gabriela
    Yokoyama, Keita
    Gallippi, Caterina M.
    PROCEEDINGS OF THE 2020 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2020,
  • [24] A Systematic Review on 3D-Printed Imaging and Dosimetry Phantoms in Radiation Therapy
    Tino, Rance
    Yeo, Adam
    Leary, Martin
    Brandt, Milan
    Kron, Tomas
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2019, 18 : 1 - 14
  • [25] Architectural Evaluation of 3D-Printed Buildings
    Garcia-Alvarado, Rodrigo
    Moroni-Orellana, Ginnia
    Banda-Perez, Pablo
    BUILDINGS, 2021, 11 (06)
  • [26] The feasibility of K XRF bone lead measurements in mice assessed using 3D-printed phantoms
    Bider, R. C.
    Sheehan, B.
    Bock, N.
    McNeill, F. E.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2024, 10 (03)
  • [27] Evaluation of single material and multi-material patient-specific, 3D-printed radiotherapy phantoms
    Craft, D.
    Burgett, E.
    Howell, R.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S765 - S766
  • [28] Design, Development, and Evaluation of a 3D-Printed Buccal Myomucosal Flap Simulator
    Cin, Mitchell D.
    Nourmohammadi, Zahra
    Hamdan, Usama
    Zopf, David A.
    CLEFT PALATE CRANIOFACIAL JOURNAL, 2025,
  • [29] Development and evaluation of 3D-printed ocular insert containing liposomal moxifloxacin
    Duman, Gulengul
    Yildir, Ipek
    Macit, Meltem
    Genc, Ece
    Sumer, Engin
    Kale, Sedat
    Deniz, Inci
    JOURNAL OF DRUG DELIVERY SCIENCE AND TECHNOLOGY, 2024, 92
  • [30] Development and Evaluation of 3D-Printed Dry Microneedle Electrodes for Surface Electromyography
    Krieger, Kevin J.
    Liegey, Jeremy
    Cahill, Ellen M.
    Bertollo, Nicky
    Lowery, Madeleine M.
    O'Cearbhaill, Eoin D.
    ADVANCED MATERIALS TECHNOLOGIES, 2020, 5 (10):