Spectral matching consideration in the design of a novel x-ray image intensifier

被引:3
|
作者
Yu, Chunyu [1 ]
Chang, Benkang
Wei, Dianxiu
机构
[1] Peking Univ, Shenzhen Grad Sch, Informat Engn Inst, Shenzhen 518055, Guangdong, Peoples R China
[2] Nanjing Univ Sci & Technol, Sch Elect Engn & Optoelect Technol, Nanjing 210094, Peoples R China
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2006年 / 77卷 / 12期
关键词
D O I
10.1063/1.2400022
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this article, a novel x-ray image intensifier is introduced. It is mainly composed of an x-ray intensifying screen and a low-light-level (L-3) image intensifier. In order to obtain a bright enough image, the spectral compatibility among three different combinations of the x-ray intensifying screen and the photocathode is analyzed. The comparison indicates that a (Zn,Cd)S:Ag screen is superior to either a CaWO4 screen or a Gd2O2S:Tb screen when combined with the Super S-25 photocathode and spectral compatibility analysis is a useful guide when designing an optoelectronic imaging device. (c) 2006 American Institute of Physics.
引用
收藏
页数:3
相关论文
共 50 条
  • [41] ANALYSIS OF THE EFFECTIVENESS OF AN X-RAY IMAGE INTENSIFIER WITH CHANNEL MULTIPLICATION.
    Nesterov, L.A.
    Bochkarev, V.P.
    Radio Engineering and Electronic Physics (English translation of Radiotekhnika i Elektronika), 1983, 27 (08): : 162 - 167
  • [42] The solid-state x-ray image intensifier (SSXII): An EMCCD-Based x-ray detector
    Kuhls-Gilcrist, Andrew
    Yadava, Girijesh
    Patel, Vikas
    Jain, Amit
    Bednarek, Daniel R.
    Rudin, Stephen
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [43] A NOVEL ITERATIVE MATCHING SCHEME BASED ON HOMOGRAPHY METHOD FOR X-RAY IMAGE
    Song, Lujie
    Zou, Haibo
    Ji, Zhenyu
    Xie, Xiaoming
    Li, Wei
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2020, 20 (06)
  • [44] Phantom Studies of a Newly Developed Solid State X-Ray Image Intensifier (SSXII) for X-Ray Image Guided Neurovascular Interventions
    Nagesh, S. Setlur
    Sharma, P.
    Singh, V.
    Jain, A.
    Ionita, C.
    Titus, A.
    Cartwright, A.
    Bednarek, D.
    Rudin, S.
    MEDICAL PHYSICS, 2012, 39 (06) : 3894 - 3895
  • [45] Lead foil in dental X-ray film: Backscattering rejection or image intensifier?
    Hoennicke, M. G.
    Delben, G. J.
    Godoi, W. C.
    Swinka-Filho, V.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 763 : 104 - 111
  • [46] Generalized performance evaluation of x-ray image intensifier compared with a microangiographic system
    Yadava, GK
    Kyprianou, LS
    Rudin, S
    Bednarek, DR
    Hoffmann, KR
    MEDICAL IMAGING 2005: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2005, 5745 : 419 - 429
  • [47] AN IMAGE INTENSIFIER - TELEVISION SYSTEM FOR DIRECT RECORDING OF X-RAY DIFFRACTION PATTERNS
    ARNDT, UW
    AMBROSE, BK
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1968, NS15 (03) : 92 - &
  • [48] X-RAY IMAGE INTENSIFIER TUBES USING RARE EARTH OXYSULFIDE PHOSPHORS
    WANG, SP
    LAUDI, O
    LUCKS, H
    WICKERSHEIM, KA
    BUCHANAN, RA
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1970, NS17 (01) : 49 - +
  • [49] A YEARS EXPERIENCE WITH A 57 CM IMAGE INTENSIFIER IN A GENERAL X-RAY ROOM
    GEORGI, M
    PRAGER, P
    BUSCH, HP
    STRAUSS, L
    WETZEL, E
    NEUMANN, D
    WEIHER, M
    REGENFUSS, W
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1985, 142 (03): : 326 - 332
  • [50] 35 MM CINE CAMERA INCORPORATING A PHILIPS X-RAY IMAGE INTENSIFIER
    ARDRAN, GM
    WYATT, DG
    JOURNAL OF PHYSIOLOGY-LONDON, 1954, 126 (03): : P1 - P2