Fast quantitative three-dimensional ultrashort echo time (UTE) Cones magnetic resonance imaging of major tissues in the knee joint using extended sprial sampling

被引:5
|
作者
Wan, Lidi [1 ,2 ]
Ma, Yajun [2 ]
Yang, Jiawei [1 ]
Jerban, Saeed [2 ]
Searleman, Adam C. [2 ]
Carl, Michael [3 ]
Le, Nicole [4 ]
Chang, Eric Y. [2 ,4 ]
Tang, Guangyu [1 ]
Du, Jiang [2 ]
机构
[1] Tongji Univ, Dept Radiol, Peoples Hosp 10, Shanghai 200072, Peoples R China
[2] Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA
[3] GE Healthcare, San Diego, CA USA
[4] Vet Affairs San Diego Healthcare Syst, Radiol Serv, San Diego, CA USA
基金
美国国家卫生研究院;
关键词
knee joint; major tissues; quantitative; Sampling Window; UTE imaging; CARTILAGE; RELAXATION; SEQUENCE; OSTEOARTHRITIS; ASSOCIATION; TENDONS; WATER; MRI; T-1; T2;
D O I
10.1002/nbm.4376
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The purpose of this study is to investigate the effect of extending the spiral sampling window on quantitative 3D ultrashort echo time (UTE) Cones imaging of major knee joint tissues including articular cartilage, menisci, tendons and ligaments at 3 T. Nine cadaveric human whole knee specimens were imaged on a 3 T clinical MRI scanner. A series of quantitative 3D UTE Cones imaging biomarkers including T-2*, T-1, adiabatic T-1 rho, magnetization transfer ratio (MTR) and macromolecular fraction (MMF) were estimated using spiral sampling trajectories with various durations. Errors in UTE MRI biomarkers as a function of sampling time were evaluated using a nonstretched spiral trajectory as a reference standard. No significant differences were observed by increasing the spiral sampling window from 1116 to 2232 mu s in the calculated T-2*, T-1, adiabatic T-1 rho, MTR and MMF, as allP-values were over .05 as assessed by ANOVA with two-sided Dunnett's test. Although extending the sampling window results in signal loss for short T(2)components, there was limited effect on the calculated quantitative biomarkers, with error percentages typically smaller than 5% in all the evaluated tissues. The total scan time can be reduced by up to 54% with quantification errors of less than 5% in any evaluated major tissue in the knee joint, suggesting that 3D UTE Cones MRI techniques can be greatly accelerated by using a longer spiral sampling window without causing additional quantitative bias.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] High-resolution morphologic and ultrashort time-to-echo quantitative magnetic resonance imaging of the temporomandibular joint
    Bae, Won C.
    Tafur, Monica
    Chang, Eric Y.
    Du, Jiang
    Biswas, Reni
    Kwack, Kyu-Sung
    Healey, Robert
    Statum, Sheronda
    Chung, Christine B.
    SKELETAL RADIOLOGY, 2016, 45 (03) : 383 - 391
  • [32] High-resolution morphologic and ultrashort time-to-echo quantitative magnetic resonance imaging of the temporomandibular joint
    Won C. Bae
    Monica Tafur
    Eric Y. Chang
    Jiang Du
    Reni Biswas
    Kyu-Sung Kwack
    Robert Healey
    Sheronda Statum
    Christine B. Chung
    Skeletal Radiology, 2016, 45 : 383 - 391
  • [33] Optimized three-dimensional ultrashort echo time: Magnetic resonance fingerprinting for myelin tissue fraction mapping
    Zhou, Zihan
    Li, Qing
    Liao, Congyu
    Cao, Xiaozhi
    Liang, Hui
    Chen, Quan
    Pu, Run
    Ye, Huihui
    Tong, Qiqi
    He, Hongjian
    Zhong, Jianhui
    HUMAN BRAIN MAPPING, 2023, 44 (06) : 2209 - 2223
  • [34] Knee Imaging: Rapid Three-Dimensional Fast Spin-Echo Using Compressed Sensing
    Kijowski, Richard
    Rosas, Humberto
    Samsonov, Alexey
    King, Kevin
    Peters, Rob
    Liu, Fang
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 45 (06) : 1712 - 1722
  • [35] Fast volumetric imaging of bound and pore water in cortical bone using three-dimensional ultrashort-TE (UTE) and inversion recovery UTE sequences
    Chen, Jun
    Carl, Michael
    Ma, Yajun
    Shao, Hongda
    Lu, Xing
    Chen, Bimin
    Chang, Eric Y.
    Wu, Zhihong
    Du, Jiang
    NMR IN BIOMEDICINE, 2016, 29 (10) : 1373 - 1380
  • [36] Study of bubble dynamics in gas-solid fluidized beds using ultrashort echo time (UTE) magnetic resonance imaging (MRI)
    Fabich, Hilary T.
    Sederman, Andrew J.
    Holland, Daniel J.
    CHEMICAL ENGINEERING SCIENCE, 2017, 172 : 476 - 486
  • [37] Accurate T1 mapping of short T2 tissues using a three-dimensional ultrashort echo time cones actual flip angle imaging-variable repetition time (3D UTE-Cones AFI-VTR) method
    Ma, Ya-Jun
    Lu, Xing
    Carl, Michael
    Zhu, Yanchun
    Szeverenyi, Nikolaus M.
    Bydder, Graeme M.
    Chang, Eric Y.
    Du, Jiang
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (02) : 598 - 608
  • [38] Rapid acquisition of magnetic resonance imaging of the shoulder using three-dimensional fast spin echo sequence with compressed sensing
    Lee, Seung Hyun
    Lee, Young Han
    Song, Ho-Taek
    Suh, Jin-Suck
    MAGNETIC RESONANCE IMAGING, 2017, 42 : 152 - 157
  • [39] Magnetic resonance imaging of short T2 relaxation components in tissue using ultrashort echo time (UTE) pulse sequences
    Bydder, M
    Znamirowski, RM
    Bydder, GM
    CURRENT MEDICAL IMAGING REVIEWS, 2006, 2 (01) : 79 - 90
  • [40] The value of magnetic resonance ultrashort echo time imaging to evaluate non-calcified cartilage of the knee joint and its damage
    Hu, Yawen
    Xu, Jun
    Zhou, Ruizhi
    Xu, Qi
    Sun, Shiqing
    Wang, Wenzhe
    Chen, Haisong
    HELIYON, 2023, 9 (03)