Fast quantitative three-dimensional ultrashort echo time (UTE) Cones magnetic resonance imaging of major tissues in the knee joint using extended sprial sampling

被引:5
|
作者
Wan, Lidi [1 ,2 ]
Ma, Yajun [2 ]
Yang, Jiawei [1 ]
Jerban, Saeed [2 ]
Searleman, Adam C. [2 ]
Carl, Michael [3 ]
Le, Nicole [4 ]
Chang, Eric Y. [2 ,4 ]
Tang, Guangyu [1 ]
Du, Jiang [2 ]
机构
[1] Tongji Univ, Dept Radiol, Peoples Hosp 10, Shanghai 200072, Peoples R China
[2] Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA
[3] GE Healthcare, San Diego, CA USA
[4] Vet Affairs San Diego Healthcare Syst, Radiol Serv, San Diego, CA USA
基金
美国国家卫生研究院;
关键词
knee joint; major tissues; quantitative; Sampling Window; UTE imaging; CARTILAGE; RELAXATION; SEQUENCE; OSTEOARTHRITIS; ASSOCIATION; TENDONS; WATER; MRI; T-1; T2;
D O I
10.1002/nbm.4376
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The purpose of this study is to investigate the effect of extending the spiral sampling window on quantitative 3D ultrashort echo time (UTE) Cones imaging of major knee joint tissues including articular cartilage, menisci, tendons and ligaments at 3 T. Nine cadaveric human whole knee specimens were imaged on a 3 T clinical MRI scanner. A series of quantitative 3D UTE Cones imaging biomarkers including T-2*, T-1, adiabatic T-1 rho, magnetization transfer ratio (MTR) and macromolecular fraction (MMF) were estimated using spiral sampling trajectories with various durations. Errors in UTE MRI biomarkers as a function of sampling time were evaluated using a nonstretched spiral trajectory as a reference standard. No significant differences were observed by increasing the spiral sampling window from 1116 to 2232 mu s in the calculated T-2*, T-1, adiabatic T-1 rho, MTR and MMF, as allP-values were over .05 as assessed by ANOVA with two-sided Dunnett's test. Although extending the sampling window results in signal loss for short T(2)components, there was limited effect on the calculated quantitative biomarkers, with error percentages typically smaller than 5% in all the evaluated tissues. The total scan time can be reduced by up to 54% with quantification errors of less than 5% in any evaluated major tissue in the knee joint, suggesting that 3D UTE Cones MRI techniques can be greatly accelerated by using a longer spiral sampling window without causing additional quantitative bias.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Quantitative differentiation of tendon and ligament using magnetic resonance imaging ultrashort echo time T2*mapping of normal knee joint
    Okuda, Miho
    Kobayashi, Satoshi
    Toyooka, Kazu
    Yoshimizu, Rikuto
    Nakase, Junsuke
    Hayashi, Hiroyuki
    Ueda, Yu
    Gabata, Toshifumi
    ACTA RADIOLOGICA, 2022, 63 (11) : 1489 - 1496
  • [22] Feasibility of three-dimensional ultrashort echo time magnetic resonance imaging at 1.5 T for the diagnosis of skull fractures
    Wu, Hao
    Zhong, Yu-min
    Nie, Quan-min
    Chen, Wei-bo
    Guo, Lie-mei
    Yang, Xi
    Zhang, Hong
    Lin, Yi
    Xu, Jian-rong
    Dai, Yong-ming
    Zhu, Ming
    EUROPEAN RADIOLOGY, 2016, 26 (01) : 138 - 146
  • [23] Three-dimensional ultrashort echo-time imaging using a FLORET trajectory
    Robison, Ryan K.
    Anderson, Ashley G., III
    Pipe, James G.
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (03) : 1038 - 1049
  • [24] Spatially resolved polymer mobilization revisited - Three-dimensional, UltraShort Echo Time (3D UTE) magnetic resonance imaging of sodium alginate matrix tablets
    Baran, Ewelina
    Birczynski, Artur
    Dorozynski, Przemyslaw
    Kulinowski, Piotr
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2023, 649 : 626 - 634
  • [25] Correlation between the elastic modulus of anterior cruciate ligament (ACL) and quantitative ultrashort echo time (UTE) magnetic resonance imaging
    Jerban, Saeed
    Hananouchi, Takehito
    Ma, Yajun
    Namiranian, Behnam
    Dorthe, Erik W.
    Wong, Jonathan H.
    Shojaeiadib, Niloofar
    Wu, Mei
    Du, Jiang
    D'Lima, Darryl
    Chung, Christine B.
    Chang, Eric Y.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2022, 40 (10) : 2330 - 2339
  • [26] Measurement of cartilage thickness in the human knee-joint by magnetic resonance imaging using a three-dimensional gradient-echo sequence
    Kladny, B
    Martus, P
    Schiwy-Bochat, KH
    Weseloh, G
    Swoboda, B
    INTERNATIONAL ORTHOPAEDICS, 1999, 23 (05) : 264 - 267
  • [27] Measurement of cartilage thickness in the human knee-joint by magnetic resonance imaging using a three-dimensional gradient-echo sequence
    B. Kladny
    P. Martus
    K. -H. Schiwy-Bochat
    G. Weseloh
    B. Swoboda
    International Orthopaedics, 1999, 23 : 264 - 267
  • [28] Three-dimensional radial ultrashort echo-time imaging with T2 adapted sampling
    Rahmer, J
    Börnert, P
    Groen, J
    Bos, C
    MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (05) : 1075 - 1082
  • [29] Comparison of lung imaging using three-dimensional ultrashort echo time and zero echo time sequences: preliminary study
    Kyungsoo Bae
    Kyung Nyeo Jeon
    Moon Jung Hwang
    Joon Sung Lee
    Ji Young Ha
    Kyeong Hwa Ryu
    Ho Cheol Kim
    European Radiology, 2019, 29 : 2253 - 2262
  • [30] Comparison of lung imaging using three-dimensional ultrashort echo time and zero echo time sequences: preliminary study
    Bae, Kyungsoo
    Jeon, Kyung Nyeo
    Hwang, Moon Jung
    Lee, Joon Sung
    Ha, Ji Young
    Ryu, Kyeong Hwa
    Kim, Ho Cheol
    EUROPEAN RADIOLOGY, 2019, 29 (05) : 2253 - 2262