Comparison of corneal power, corneal astigmatism, and axis location in normal eyes obtained from an autokeratometer and a corneal topographer

被引:45
|
作者
Kobashi, Hidenaga [1 ]
Kamiya, Kazutaka
Igarashi, Akihito
Ishii, Rie
Sato, Nobuyuki
Wang, Guoqin [2 ]
Shimizu, Kimiya
机构
[1] Kitasato Univ, Sch Med, Dept Ophthalmol, Minami Ku, Sagamihara, Kanagawa 2288555, Japan
[2] Kitasato Univ, Sch Med, Kitasato Clin Res Ctr, Sagamihara, Kanagawa 2288555, Japan
来源
关键词
ANTERIOR-CHAMBER DEPTH; CATARACT-SURGERY; INTRAOCULAR-LENS; KERATOMETRY; INCISIONS; BIOMETRY; VIDEOKERATOGRAPHY; KERATOTOMY; PREVALENCE; ACCURACY;
D O I
10.1016/j.jcrs.2011.11.026
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To assess the repeatability and agreement of corneal power, corneal astigmatism, axis location, and astigmatic vector component measurements using an autokeratometer and a corneal topographer in healthy subjects. SETTING: Department of Ophthalmology, Kitasato University, Kanagawa, Japan. DESIGN: Evaluation of diagnostic test or technology. METHODS: Keratometric readings were obtained with an ARK-700A autokeratometer and an Atlas corneal topographer. Measurement repeatability and agreement in corneal power (flattest and steepest meridians), mean corneal power, corneal astigmatism, axis location, and astigmatic vector components (Jackson cross-cylinders J0, J45) between the devices were evaluated. RESULTS: The repeatability of both devices in the flattest and steepest meridians, mean corneal power, corneal astigmatism, axis location, J0, and J45 was high. The 95% limits of agreement between the 2 devices were from -0.51 to 0.48 diopters (D) for the flattest meridian, from -0.74 to 0.71 D for the steepest meridian, from -0.56 to 0.53 D for the mean corneal power, from -0.58 to 0.58 D for corneal astigmatism, from -15.3 to 17.5 degrees for axis location, from -0.32 to 0.30 D for J0, and from -0.22 to 0.20 D for J45. In eyes with a small amount of astigmatism, there was wider disagreement in axis location between the 2 devices. CONCLUSIONS: Both devices provided excellent repeatability and comparability of corneal powers and corneal astigmatism, suggesting they can be used interchangeably for measurement of these corneal variables in healthy eyes. However, disagreement in axis location between the 2 devices was not negligible in some eyes, especially in those with low astigmatism.
引用
收藏
页码:648 / 654
页数:7
相关论文
共 50 条
  • [1] Comparison of corneal power and astigmatism in normal eyes using 4 different devices
    Han, K. E.
    Lee, H. K.
    Hwang, H. S.
    Shin, M. C.
    ACTA OPHTHALMOLOGICA, 2014, 92
  • [2] Repeatability, reproducibility, and agreement of corneal power measurements obtained with a new corneal topographer
    Mao, Xinjie
    Savini, Giacomo
    Zhuo, Zuopao
    Feng, Yifan
    Zhang, Jian
    Wang, Qinmei
    Chen, Hao
    Huang, Jinhai
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (10): : 1561 - 1569
  • [3] Comparison of corneal astigmatism and axis location in cataract patients measured by total corneal power, automated keratometry, and simulated keratometry
    Srivannaboon, Sabong
    Soeharnila
    Chirapapaisan, Chareenun
    Chonpimai, Pratuangsri
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (12): : 2088 - 2093
  • [4] Repeatability and comparability of corneal power and corneal astigmatism obtained from a point-source color light-emitting diode topographer, a Placido-based corneal topographer, and a low-coherence reflectometer
    Ventura, Bruna V.
    Al-Mohtaseb, Zaina
    Wang, Li
    Koch, Douglas D.
    Weikert, Mitchell P.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (10): : 2242 - 2250
  • [5] Precision and Agreement of Corneal Power Measurements Obtained Using a New Corneal Topographer OphthaTOP
    Huang, Jinhai
    Savini, Giacomo
    Chen, Hao
    Bao, Fangjun
    Li, Yuanguang
    Chen, Haisi
    Lu, Weicong
    Yu, Ye
    Wang, Qinmei
    PLOS ONE, 2015, 10 (01):
  • [6] Influence of Posterior Corneal Astigmatism on Total Corneal Astigmatism in Eyes With Keratoconus
    Savini, Giacomo
    Naeser, Kristian
    Schiano-Lomoriello, Domenico
    Mularoni, Alessandro
    CORNEA, 2016, 35 (11) : 1427 - 1433
  • [7] A novel color-LED corneal topographer to assess astigmatism in pseudophakic eyes
    Ferreira, Tiago B.
    Ribeiro, Filomena J.
    CLINICAL OPHTHALMOLOGY, 2016, 10 : 1521 - 1529
  • [8] Mean Posterior Corneal Power and Astigmatism in Normal Versus Keratoconic Eyes
    Feizi, Sepehr
    Delfazayebaher, Siamak
    Javadi, Mohammad Ali
    Karimian, Farid
    Ownagh, Vahid
    Sadeghpour, Fatemeh
    JOURNAL OF OPHTHALMIC & VISION RESEARCH, 2018, 13 (02) : 93 - 100
  • [9] A comparison of the ARK-700A autokeratometer and Medmont E300 corneal topographer when measuring peripheral corneal curvature
    González-Méijomel, JM
    Jorge, J
    Queiros, A
    Almeida, JB
    Parafita, MA
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2004, 24 (05) : 391 - 398
  • [10] Influence of posterior corneal astigmatism on total corneal astigmatism in eyes with moderate to high astigmatism
    Savini, Giacomo
    Versaci, Francesco
    Vestri, Gabriele
    Ducoli, Pietro
    Naeser, Kristian
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (10): : 1645 - 1653