Study on Partial Discharge Pulse Attenuation Characteristics in 110 kV XLPE Power Cable

被引:0
|
作者
Gu, Xiao [1 ]
Liu, Bin [1 ]
Xu, Yang [1 ]
Yang, Dan [2 ]
机构
[1] State Key Lab Elect Insulat & Power Equipment, Xian, Peoples R China
[2] China Elect Power Res Inst, Wuhan, Peoples R China
关键词
Partial Discharges; Attenuation; Cable; PROPAGATION;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The attenuation characteristics of a partial discharge (PD) pulse propagating in a long-distance power cable is always a concern for PD detection. The high frequency attenuation of the symmetric PD pulse waveform has been previously well modeled, and the approximate solution concerning the asymmetric pulse has also been discussed. In this paper, a method to calculate the attenuation characteristics of the asymmetric PD calibration pulse is proposed, based on the measured attenuation constant of sinusoidal wave signals propagating in different lengths of 110 kV cross-linked polyethylene (XLPE) cables. The amplitude, pulse width, and area of the attenuated calibration pulse are measured in the field to verify the method. The results indicate that the product of the exponential function and Gaussian error function can be used to describe the attenuation characteristics of the calibration pulse, and the area under the pulse curve is unchanged.
引用
收藏
页码:788 / 791
页数:4
相关论文
共 50 条
  • [41] Simulation of Electric Field Around Typical Defects in 110kV XLPE Power Cable Joints
    Zhou, Xiangxian
    Cao, Junping
    Wang, Shaohua
    Jiang, Yukuan
    Li, Te
    Zou, Yang
    CONFERENCE PROCEEDINGS OF 2017 INTERNATIONAL CONFERENCE ON CIRCUITS, DEVICES AND SYSTEMS (ICCDS), 2017, : 21 - 24
  • [42] The influence of water in XLPE cable conductor on XLPE insulation breakdown voltage and partial discharge
    Nikolajevic, SV
    STojanovic, BB
    CONFERENCE RECORD OF THE 1996 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, VOLS 1 AND 2, 1996, : 604 - 607
  • [43] Characteristics of partial discharge pulses propagation in shielded power cable
    Ouatah, Elhanafi
    Megherfi, Soufiane
    Haroun, Karim
    Zebboudj, Youcef
    ELECTRIC POWER SYSTEMS RESEARCH, 2013, 99 : 38 - 44
  • [44] On-line partial discharge monitor system of XLPE power cable based on virtual instrument
    Cheng, YH
    Chen, XL
    Zhang, SF
    Lv, YH
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2003, : 207 - 210
  • [45] Simulated Electromagnetic Field Profile Inside and Outside XLPE Power Cable due to Partial Discharge
    Ghani, A. B. A.
    Shafi, H.
    Chakrabarty, C. K.
    2007 IEEE INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS, VOLS 1 AND 2, 2007, : 71 - +
  • [46] Typical Defect Simulation of 110kV Cable and Its Partial Discharge Characteristic Test
    Song, Xinming
    Xia, Yunfeng
    Jia, Zhidong
    Li, Yishan
    Wang, Xilin
    2018 12TH INTERNATIONAL CONFERENCE ON THE PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS (ICPADM 2018), 2018, : 764 - 767
  • [47] A Analysis on the Partial Discharge Characteristics of 22.9kV CN-CV Power Cable Termination Defect
    Park J.-M.
    Kang J.-Y.
    Moon Y.-C.
    Lee J.-S.
    Jeon J.-C.
    Transactions of the Korean Institute of Electrical Engineers, 2023, 72 (11): : 1546 - 1553
  • [48] New approach in partial discharge diagnosis and maintenance of 22.9 kV XLPE power cables in service
    Park, Ji Man
    Jeon, Jeong Chay
    Han, Ga Ram
    ELECTRICAL ENGINEERING, 2019, 101 (04) : 1199 - 1209
  • [49] New approach in partial discharge diagnosis and maintenance of 22.9 kV XLPE power cables in service
    Ji Man Park
    Jeong Chay Jeon
    Ga Ram Han
    Electrical Engineering, 2019, 101 : 1199 - 1209
  • [50] The Effects of Overvoltage Aging on 20 kV XLPE Power Cable
    Uydur, Cihat Cagdas
    Arikan, Oktay
    Kucukaydin, Baris
    Dursun, Bekir
    Kumru, Celal Fadil
    2019 11TH INTERNATIONAL CONFERENCE ON ELECTRICAL AND ELECTRONICS ENGINEERING (ELECO 2019), 2019, : 353 - 357