Study on Partial Discharge Pulse Attenuation Characteristics in 110 kV XLPE Power Cable

被引:0
|
作者
Gu, Xiao [1 ]
Liu, Bin [1 ]
Xu, Yang [1 ]
Yang, Dan [2 ]
机构
[1] State Key Lab Elect Insulat & Power Equipment, Xian, Peoples R China
[2] China Elect Power Res Inst, Wuhan, Peoples R China
关键词
Partial Discharges; Attenuation; Cable; PROPAGATION;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The attenuation characteristics of a partial discharge (PD) pulse propagating in a long-distance power cable is always a concern for PD detection. The high frequency attenuation of the symmetric PD pulse waveform has been previously well modeled, and the approximate solution concerning the asymmetric pulse has also been discussed. In this paper, a method to calculate the attenuation characteristics of the asymmetric PD calibration pulse is proposed, based on the measured attenuation constant of sinusoidal wave signals propagating in different lengths of 110 kV cross-linked polyethylene (XLPE) cables. The amplitude, pulse width, and area of the attenuated calibration pulse are measured in the field to verify the method. The results indicate that the product of the exponential function and Gaussian error function can be used to describe the attenuation characteristics of the calibration pulse, and the area under the pulse curve is unchanged.
引用
收藏
页码:788 / 791
页数:4
相关论文
共 50 条
  • [21] Partial Discharge Pulse Propagation in Power Cable and Partial Discharge Monitoring System
    Sheng, Bojie
    Zhou, Chengke
    Hepburn, Donald M.
    Dong, Xiang
    Peers, Graham
    Zhou, Wenjun
    Tang, Zeyang
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2014, 21 (03) : 948 - 956
  • [22] Partial discharge pulse propagation in power cable and partial discharge monitoring system
    1600, Institute of Electrical and Electronics Engineers Inc., United States (21):
  • [23] The Relationship between Partial Discharge Behavior and the Degradation of 10 kV XLPE Cable Joints
    Hui, Baojun
    Liu, Chang
    Tian, Ye
    Fu, Mingli
    Xu, Yang
    Zhang, Yuhang
    2016 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (CMD), 2016, : 843 - 846
  • [24] Study on the time evolution of partial discharge characteristics and interfacial phenomena of simulated XLPE cable joint
    Yoshida, H
    Tian, ZH
    Hikita, M
    Miyata, H
    1998 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS, PROCEEDINGS, 1998, : 501 - 504
  • [25] Study on Characteristics of Partial Discharge in XLPE Cable under Damped AC Voltage at Different Frequencies
    Yu, Peixiang
    Zhang, Long
    Li, Ruipeng
    Yang, Yuqi
    Li, Hongjie
    MODERN TECHNOLOGIES IN MATERIALS, MECHANICS AND INTELLIGENT SYSTEMS, 2014, 1049 : 750 - +
  • [26] Application of distributed partial discharge on-line monitoring technology in Shanghai 500 kV XLPE power cable line
    Jiang, Yun
    Zhou, Yunjie
    Gaodianya Jishu/High Voltage Engineering, 2015, 41 (04): : 1249 - 1256
  • [27] Development of on-line partial discharge monitor system for XLPE power cable
    Tang, Zhong
    Zou, Yunping
    PROCEEDINGS OF THE 41ST INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, VOLS 1 AND 2, 2006, : 640 - +
  • [28] Partial Discharge Characteristics of XLPE Cable Joint and Interfacial Phenomena with Artificial Defects
    Arief, Yanuar Z.
    Ahmad, Hussein
    Hikita, Masayuki
    2008 IEEE 2ND INTERNATIONAL POWER AND ENERGY CONFERENCE: PECON, VOLS 1-3, 2008, : 1518 - +
  • [29] Influence of contaminants on partial discharge characteristics for model XLPE transmission cable joints
    Nadolny, Z
    Braun, JM
    Densley, RJ
    CONFERENCE RECORD OF THE 1998 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, VOLS 1 AND 2, 1998, : 140 - 143
  • [30] Partial Discharge Characteristics of Typical Defects in XLPE Cable Under DC Voltage
    Du H.
    Guan H.
    Chen X.
    Hou S.
    Yang M.
    Wang X.
    Gaodianya Jishu/High Voltage Engineering, 2021, 47 (02): : 555 - 563