Balanced left ventricular myocardial SSFP-tagging at 1.5T and 3T

被引:10
|
作者
Markl, M. [1 ]
Scherer, S. [1 ]
Frydrychowicz, A. [1 ]
Burger, D. [1 ]
Geibel, A. [2 ]
Hennig, J. [1 ]
机构
[1] Univ Freiburg, Dept Diagnost Radiol, Univ Hosp, D-79106 Freiburg, Germany
[2] Univ Freiburg, Dept Cardiol & Angiol, Univ Hosp, D-79106 Freiburg, Germany
关键词
tagging; SSFP; myocardial motion; cardiac MRI; 3; Tesla;
D O I
10.1002/mrm.21674
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of the study was to evaluate the performance of steady-state free precession (SSFP)-tagging at 1.5T and 3T and to define the ideal settings with respect to optimized tag contrast throughout the cardiac cycle for both field strengths. To identify optimal imaging parameters data acquisition was repeated for different flip angles. Left ventricular tag-tissue contrast, tag fading times, tag persistence, and myocardial signal-to-noise ratio (SNR) were quantified in basal, mid-ventricular, and apical slice locations. To assess the effect of field strength on image quality and artifact level, additional semiquantitative image grading was performed by two experienced readers. SSFP-tagging at 3T proved superior to 1.5T and provided significantly enhanced tag persistence and myocardial SNR while maintaining overall image quality and artifact level. The definition of a tag quality index demonstrated optimal SSFP-tagging performance for a flip angle of 20 degrees. Diastolic tag visibility was improved at 3T and resulted in enhanced average tag persistence of 789 +/- 128 ms compared to 523 +/- 40 ms at 1.5T. For SSFP-tagging at 3T the combination of T-1 lengthening and superior myocardial SNR is highly promising and has the potential to improve the depiction of tagged myocardial function throughout the entire cardiac cycle.
引用
收藏
页码:631 / 639
页数:9
相关论文
共 50 条
  • [41] R2*imaging of transfusional iron burden at 3T and comparison with 1.5T
    Storey, Pippa
    Thompson, Alexis A.
    Carqueville, Christine L.
    Wood, John C.
    de Freitas, R. Andrew
    Rigsby, Cynthia K.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (03) : 540 - 547
  • [42] Specific absorption rate in neonates undergoing magnetic resonance procedures at 1.5T and 3T
    Malik, Shaihan J.
    Beqiri, Arian
    Price, Anthony N.
    Teixeira, Jose Nuno
    Hand, Jeffrey W.
    Hajnal, Joseph V.
    NMR IN BIOMEDICINE, 2015, 28 (03) : 344 - 352
  • [43] The relationship between myocardial and hepatic T2 and T2*at 1.5T and 3T MRI in normal and iron-overloaded patients
    Kritsaneepaiboon, Supika
    Ina, Natee
    Chotsampancharoen, Thirachit
    Roymanee, Supaporn
    Cheewatanakornkul, Sirichai
    ACTA RADIOLOGICA, 2018, 59 (03) : 355 - 362
  • [44] COMPARISON OF NATIVE MYOCARDIAL T1 AND T2 MAPPING AT 1.5T AND 3T IN HEALTHY VOLUNTEERS FOLLOWING INSTALLATION OF NEW SCANNERS
    Tsoumani, Zoi
    Nakou, Eleni
    Alpendurada, Francisco
    Pennell, Dudley J.
    Lota, Amrit
    HEART, 2023, 109 (SUPPL_1) : A17 - A18
  • [45] Comparison of native myocardial T1 and T2 mapping at 1.5T and 3T in healthy volunteers Reference values and clinical implications
    Granitz, Marcel
    Motloch, Lukas J.
    Granitz, Christina
    Meissnitzer, Matthias
    Hitzl, Wolfgang
    Hergan, Klaus
    Schlattau, Alexander
    WIENER KLINISCHE WOCHENSCHRIFT, 2019, 131 (7-8) : 143 - 155
  • [46] No Increased Mercury Release from Dental Restorations at 1.5T, 3T, or 7T MRI
    Burkett, Brian J.
    Rasmussen, Chad M.
    Fillmore, W. Jonathan
    McDonald, Jennifer S.
    McDonald, Robert J.
    Fagan, Andrew J.
    Erdahl, Sarah A.
    Eckdahl, Steven J.
    Welker, Kirk M.
    MAGNETIC RESONANCE IN MEDICINE, 2024, 91 (02) : 660 - 669
  • [47] Standardization of myocardial T1 time measurements in clinical setting using MOLLI, shMOLLI and LL at 1.5T and 3T - the CONSEPT study
    Toby Rogers
    Darius Dabir
    Tobias Voigt
    Tobias Schaeffter
    Eike Nagel
    Valentina O Puntmann
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [48] 1.5T and 3T Quantitative Myocardial Perfusion Reserve for Detection of Relevant Coronary Artery Stenosis - A Comparison to Fractional Flow Reserve
    Bernhardt, Peter
    Walcher, Thomas
    Rottbauer, Wolfgang
    Woehrle, Jochen
    CIRCULATION, 2012, 126 (21)
  • [49] Comparison of 1.5T and 3T 1H MR spectroscopy for human brain tumors
    Kim, Ji-hoon
    Chang, Kee-Hyun
    Na, Dong Gyu
    Song, In Chan
    Kim, Seung Ja
    Kwon, Bae Ju
    Han, Moon Hee
    KOREAN JOURNAL OF RADIOLOGY, 2006, 7 (03) : 156 - 161
  • [50] Improved BOLD Signal Detectability of Short Breath Holding Duration at 3T: A Comparison with 1.5T
    Kuan, W.
    Hsu, Y.
    Lim, K.
    Liu, H.
    MEDICAL PHYSICS, 2008, 35 (06)