Voltammetric determination of promethazine by platinum and glassy carbon electrodes

被引:0
|
作者
Uslu, B
Biryol, I
Ozkan, SA
Senturk, Z
机构
关键词
promethazine; voltammetry; platinum and glassy carbon electrodes;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The electrochemical oxidation of promethazine was studied by linear sweep and cyclic voltammetry on platinum and glassy carbon electrodes. The dependence of current intensities and potentials on pH, concentration, scan rate and nature of the buffer was examined. Linear calibration plots were obtained in phosphate buffer (pH 7.0) and acetate buffer (pH 4.7) for platinum and glassy carbon electrode, respectively.
引用
收藏
页码:323 / 328
页数:6
相关论文
共 50 条
  • [21] Adsorptive Voltammetric Determination of Nimesulide at Glassy Carbon Electrode
    El-Sayed, Gamal O.
    Yasin, Shalaby A.
    El Ries, Mohammed A.
    El-Badawy, Azza A.
    LATIN AMERICAN JOURNAL OF PHARMACY, 2009, 28 (05): : 741 - 746
  • [22] Adsorptive voltammetric determination of orthophosphate at a glassy carbon electrode
    Tanaka, T
    Miura, M
    Ishiyama, T
    JOURNAL OF TRACE AND MICROPROBE TECHNIQUES, 2001, 19 (04): : 591 - 599
  • [23] Influence of anodic oxidation of glassy carbon surface on voltammetric behavior of Nafion®-coated glassy carbon electrodes
    Maruyama, J
    Abe, I
    ELECTROCHIMICA ACTA, 2001, 46 (22) : 3381 - 3386
  • [24] Voltammetric Determination of Arsenic with Modified Glassy Carbon Electrode
    Stankovic, Anamarija
    Kajinic, Zana
    Turkalj, Jelena Vesligaj
    Romic, Zeljka
    Sikiric, Maja Dutour
    Asserghine, Abdelilah
    Nagy, Geza
    Medvidovic-Kosanovic, Martina
    ELECTROANALYSIS, 2020, 32 (05) : 1043 - 1051
  • [25] VOLTAMMETRIC DETERMINATION OF PENTACHLOROPHENOL AT A GLASSY-CARBON ELECTRODE
    GUIJARRO, EC
    YANEZSEDENO, P
    CARRAZON, JMP
    DIEZ, LMP
    ANALYST, 1988, 113 (04) : 625 - 627
  • [26] Electrochemical impedance study and sensitive voltammetric determination of Pb(II) at electrochemically activated glassy carbon electrodes
    Zen, JM
    Chung, HH
    Hangovan, G
    Kumar, AS
    ANALYST, 2000, 125 (06) : 1139 - 1146
  • [27] VOLTAMMETRIC DETERMINATION OF TRACE MERCURY IN CHLORIDE MEDIA AT GLASSY-CARBON ELECTRODES MODIFIED WITH POLYCATIONIC IONOMERS
    UGO, P
    MORETTO, LM
    MAZZOCCHIN, GA
    ANALYTICA CHIMICA ACTA, 1995, 305 (1-3) : 74 - 82
  • [28] Differential pulse voltammetric determination of uric acid on carbon-coated iron nanoparticle modified glassy carbon electrodes
    Wang, Shengfu
    Xu, Qiao
    Liu, Guodong
    ELECTROANALYSIS, 2008, 20 (10) : 1116 - 1120
  • [29] Comparative study for voltammetric investigation and trace determination of pramipexole at bare and carbon nanotube-modified glassy carbon electrodes
    Burcin Bozal-Palabiyik
    Bengi Uslu
    Ionics, 2016, 22 : 2519 - 2528
  • [30] Comparative study for voltammetric investigation and trace determination of pramipexole at bare and carbon nanotube-modified glassy carbon electrodes
    Bozal-Palabiyik, Burcin
    Uslu, Bengi
    IONICS, 2016, 22 (12) : 2519 - 2528