Nondestructive three-dimensional measurement of gas temperature distribution by phase tomography

被引:1
|
作者
Tomioka, Satoshi [1 ]
Nishiyama, Shusuke [1 ]
机构
[1] Hokkaido Univ, Fac Engn, Kita Ku, Sapporo, Hokkaido, Japan
来源
COMPUTATIONAL IMAGING X | 2012年 / 8296卷
关键词
Interferometry; Computed tomography; Refractive index; Phase unwrapping; Three-dimensional Reconstruction; Temperature;
D O I
10.1117/12.908322
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
This study presents a nondestructive three-dimensional (3D) measurement of gas temperature distribution around a heater. The distribution is obtained by a coupling method of optical interferometry and computed tomography (CT). Since the gas temperature is related to refractive index, once a series of two-dimensional (2D) phase modulation that is an integral of refractive index along an optical path is obtained, the 3D gas temperature distribution can be ideally determined in the same way as the widely-used CT to determine a distribution of attenuation factor. However, the series of 2D phase images is not complete; phase images from certain directions cannot be obtained because of limitations of the measurement system. Furthermore, the 2D images of phase modulation are not observed directly, since the interferometer can only detect a 2D image of intensity distribution called fringe pattern. To retrieve the phase modulation from the fringe pattern, both digital holography and phase unwrapping algorithm are applied. To obtain 3D gas temperature distributions with such incomplete data sets, we apply a method using localized compensator for phase unwrapping algorithm to obtain 2D modulation maps, and a maximum-likelihood tomography for a 3D reconstruction. Accuracy of each method is compared with that of conventional methods.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Three-dimensional measurement of temperature distribution in wood during Radio-Frequency/Vacuum drying
    Cai, Y
    Hayashi, K
    Sugimori, M
    MOKUZAI GAKKAISHI, 2001, 47 (05): : 389 - 396
  • [32] Three-dimensional optical tomography
    Eppstein, MJ
    Dougherty, DE
    Hawrysz, DJ
    Sevick-Muraca, EM
    OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE III, PROCEEDINGS OF, 1999, 3597 : 97 - 105
  • [33] Three-dimensional optical tomography
    Eppstein, Margaret J.
    Dougherty, David E.
    Hawrysz, Daniel J.
    Sevick-Muraca, Eva M.
    Proceedings of SPIE - The International Society for Optical Engineering, 3597 : 97 - 105
  • [34] Development and application of a three-dimensional measurement device for gas concentration
    Zhao H.
    Zhang H.
    Wang H.
    Zhang M.
    Li B.
    Wei Z.
    Zou Y.
    Meitan Xuebao/Journal of the China Coal Society, 2018, 43 (12): : 3411 - 3418
  • [35] MEASUREMENT OF THREE-DIMENSIONAL PARTICLE DISTRIBUTION BY TOMOGRAPHIC DIGITAL HOLOGRAPHY
    Tani, Shunsuke
    Tanaka, Yohsuke
    Murata, Shigeru
    PROCEEDINGS OF THE ASME/JSME/KSME JOINT FLUIDS ENGINEERING CONFERENCE, 2015, VOL 2A: FORA, PT 2, 2016,
  • [36] Measurement of the three-dimensional intensity distribution in the neighborhood of a paraxial focus
    Karman, GP
    vanDuijl, A
    Beijersbergen, MW
    Woerdman, JP
    APPLIED OPTICS, 1997, 36 (31): : 8091 - 8095
  • [37] Measurement of the three-dimensional distribution of radiation dose in grid therapy
    Trapp, JV
    Warrington, AP
    Partridge, M
    Philps, A
    Glees, J
    Tait, D
    Ahmed, R
    Leach, MO
    Webb, S
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (19): : N317 - N323
  • [38] Computerized measurement of the three-dimensional distribution of optic disc pallor
    Farmer, MJS
    Schwartz, B
    Takamoto, T
    CURRENT EYE RESEARCH, 1997, 16 (11) : 1096 - 1101
  • [39] Measurement of the three-dimensional intensity distribution in the neighborhood of a paraxial focus
    Karman, G.P.
    Van Duijl, A.
    Beijersbergen, M.W.
    Woerdman, J.P.
    Applied Optics, 1997, 36 (31): : 8091 - 8095
  • [40] Measurement of the volume of oral tumors by three-dimensional spiral computed tomography
    Cavalcanti, MGP
    Vannier, MW
    DENTOMAXILLOFACIAL RADIOLOGY, 2000, 29 (01) : 35 - 40