Computerized measurement of the three-dimensional distribution of optic disc pallor

被引:4
|
作者
Farmer, MJS [1 ]
Schwartz, B [1 ]
Takamoto, T [1 ]
机构
[1] TUFTS UNIV, SCH MED, BOSTON, MA 02116 USA
关键词
glaucoma; image analysis; optic disc; pallor; surface area; human;
D O I
10.1076/ceyr.16.11.1096.5108
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To describe a method which provides quantitative measurements of the surface area of pallor in each quadrant of the three-dimensional optic cup, using photogrammetric measurements from simultaneous stereophotographs and computerized image analysis. Methods. Simultaneous stereophotographs of one normal subject and two subjects with primary open angle glaucoma were digitized and analyzed for depth measurements. The boundaries of the optic disc, optic cup and region of pallor were identified. Pallor/disc and pallor/cup ratios were subsequently calculated for the superior, temporal, inferior and nasal walls. Results. A digitized photograph and a Laplacian-filtered image were obtained for each eye to be studied. After processing each stereo pair through a similarity sequential detection-based algorithm, depth measurements are represented as a grey scale image, a contour plot, and a wire mesh, with the boundaries of the optic disc, optic cup and pallor superimposed. Ratios are given of the surface area of pallor to the surface area of the disc and the surface area of pallor to the surface area of the cup, by quadrant. Conclusions. Determination of surface area of pallor to cup may be useful in detecting early visual field loss in glaucoma and neurological disease.
引用
收藏
页码:1096 / 1101
页数:6
相关论文
共 50 条
  • [1] REPRODUCIBILITY OF PALLOR MEASUREMENTS OF THE OPTIC DISC WITH COMPUTERIZED IMAGE-ANALYSIS
    BLANCO, AA
    COSTA, VP
    SPAETH, GL
    SMITH, M
    NICHOLL, J
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1993, 34 (04) : 1508 - 1508
  • [2] A three-dimensional computerized isometric strength measurement system
    Black, Nancy L.
    Das, Biman
    APPLIED ERGONOMICS, 2007, 38 (03) : 285 - 292
  • [3] Asymmetry of optic disc pallor: An epidemiological study
    Carassa, RG
    Schwartz, B
    Brancato, R
    Fiori, M
    Bettin, P
    Chizzoli, A
    Takamoto, T
    Pece, A
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 3840 - 3840
  • [4] Comparison of Clinical and Three-Dimensional Histomorphometric Optic Disc Margin Anatomy
    Strouthidis, Nicholas G.
    Yang, Hongli
    Downs, J. Crawford
    Burgoyne, Claude F.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (05) : 2165 - 2174
  • [5] 3-DIMENSIONAL EVALUATION OF OPTIC DISC PALLOR IN OPEN-ANGLE GLAUCOMA
    SAGATIES, MJ
    SCHWARTZ, B
    ACTA OPHTHALMOLOGICA, 1993, 71 (03): : 308 - 314
  • [6] MEASUREMENT OF OPTIC-NERVE HEAD PALLOR WITH A VIDEO-OPHTHALMOGRAPH AND WITH COMPUTERIZED BOUNDARY ANALYSIS
    MIKELBERG, FS
    DOUGLAS, GR
    DRANCE, SM
    SCHULZER, M
    SCHWARTZ, B
    NAGIN, P
    WIJSMAN, K
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 1988, 23 (03): : 120 - 123
  • [7] Optic disc pallor diagnosis using ROMF based optic disc segmentation in fundus images
    J. Jency
    S. Shunmugan
    Multimedia Tools and Applications, 2025, 84 (2) : 517 - 546
  • [8] Three-dimensional displacement measurement using diffractive optic interferometry
    Gilbert, JA
    Shepherd, RL
    Cole, HJ
    Ashley, PR
    OPTICAL ENGINEERING, 1997, 36 (12) : 3336 - 3342
  • [9] Association between optic disc pallor and lacunar stroke
    Gibbon, Samuel
    Doubal, Fergus
    Chappell, Francesca
    Wardlaw, Joanna M.
    Dhillon, Baljean
    MacGillivray, Thomas
    BMJ NEUROLOGY OPEN, 2024, 6 (02) : 1 - 7
  • [10] Three-Dimensional Measurement of Proximal Humerus Fractures Displacement: A Computerized Analysis
    Ripoll, Thomas
    Chelli, Mikael
    Johnston, Tyler
    Chaoui, Jean
    Gauci, Marc-Olivier
    Vasseur, Heloise
    Poltaretskyi, Sergii
    Boileau, Pascal
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (12)