Water Vapor Interference Correction in a Non Dispersive Infrared Multi-Gas Analyzer

被引:16
|
作者
Sun You-Wen [1 ]
Liu Wen-Qing [1 ]
Zeng Yi [1 ]
Wang Shi-Mei [1 ]
Huang Shu-Hua [1 ]
Xie Pin-Hua [1 ]
Xiao-Man, Yu [1 ]
机构
[1] Chinese Acad Sci, Key Lab Environm Opt & Technol, Anhui Inst Opt & Fine Mech, Hefei 230031, Peoples R China
基金
中国国家自然科学基金;
关键词
SYSTEM; DESIGN;
D O I
10.1088/0256-307X/28/7/073302
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
We demonstrate an effective method to eliminate the interfering effect of water vapor in a non-dispersive infrared multi-gas analyzer. The response coefficients of water vapor at each filter channel are measured from the humidity of the ambient air. Based on the proposed method, the water vapor interference is corrected with the measured response coefficients. By deducting the absorbance of each filter channel related to water vapor, the measuring precision of the analyzer is improved significantly and the concentration retrieval correlation accuracy of each target gas is more than 99%.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] Multispectral interference filters and their application to the design of compact non-dispersive infrared gas analyzers for pollution control
    Lopez, F.
    de Frutos, J.
    Sensors and Actuators, A: Physical, 1993, 37-38 (02) : 502 - 506
  • [32] Multi-gas sensing with quantum cascade laser array in the mid-infrared region
    Laurent Bizet
    Raphael Vallon
    Bertrand Parvitte
    Mickael Brun
    Gregory Maisons
    Mathieu Carras
    Virginie Zeninari
    Applied Physics B, 2017, 123
  • [33] Multi-gas sensing with quantum cascade laser array in the mid-infrared region
    Bizet, Laurent
    Vallon, Raphael
    Parvitte, Bertrand
    Brun, Mickael
    Maisons, Gregory
    Carras, Mathieu
    Zeninari, Virginie
    APPLIED PHYSICS B-LASERS AND OPTICS, 2017, 123 (05):
  • [34] Remote monitoring of multi-gas mixtures by passive standoff Fourier transform infrared radiometry
    Theriault, Jean-Marc
    Puckrin, Eldon
    Lavoie, Hugo
    APPLIED SPECTROSCOPY, 2007, 61 (06) : 630 - 637
  • [35] Gaussian distribution of stable diffusion for gas concentration correction on infrared dispersive gas sensor
    Qiang Z.
    Wang X.
    Zhang X.
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2023, 44 (02): : 138 - 145
  • [36] Non-Dispersive Infrared Gas Sensing Technology: A Review
    Jha, Ravindra Kumar
    IEEE SENSORS JOURNAL, 2022, 22 (01) : 6 - 15
  • [37] PROCESS GAS ANALYZERS USING NON-DISPERSIVE INFRARED
    DURHAM, RM
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1983, 411 : 72 - 79
  • [38] Wavelength-modulated photoacoustic spectroscopy sensor for multi-gas measurement of acetone, methane, and water vapor based on a differential acoustic resonator
    Huang, Yan
    Zhang, Tie
    Wang, Gao-Xuan
    Xing, Yu-Xin
    He, Sai-Ling
    APPLIED PHYSICS LETTERS, 2023, 122 (11)
  • [39] Investigation of non-target gas interferences on a multi-gas cavity ring-down spectrometer
    Garcia, Pablo
    Stockler, Anna Holm
    Feilberg, Anders
    Kamp, Jesper Norlem
    ATMOSPHERIC ENVIRONMENT-X, 2024, 22
  • [40] Stack emission monitoring using non-dispersive infrared spectroscopy with an optimized nonlinear absorption cross interference correction algorithm
    Sun, Y. W.
    Liu, C.
    Chan, K. L.
    Xie, P. H.
    Liu, W. Q.
    Zeng, Y.
    Wang, S. M.
    Huang, S. H.
    Chen, J.
    Wang, Y. P.
    Si, F. Q.
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2013, 6 (08) : 1993 - 2005