Diagnostic test accuracy of ultrasound for synovitis in rheumatoid arthritis: systematic review and meta-analysis

被引:61
|
作者
Takase-Minegishi, Kaoru [1 ]
Horita, Nobuyuki [2 ]
Kobayashi, Kouji [1 ]
Yoshimi, Ryusuke [3 ]
Kirino, Yohei [3 ]
Ohno, Shigeru [1 ]
Kaneko, Takeshi [2 ]
Nakajima, Hideaki [3 ]
Wakefield, Richard J. [4 ]
Emery, Paul [4 ]
机构
[1] Yokohama City Univ, Med Ctr, Ctr Rheumat Dis, Yokohama, Kanagawa, Japan
[2] Yokohama City Univ, Grad Sch Med, Dept Pulmonol, Yokohama, Kanagawa, Japan
[3] Yokohama City Univ, Grad Sch Med, Dept Stem Cell & Immune Regulat, Yokohama, Kanagawa, Japan
[4] Univ Leeds, Leeds Teaching Hosp NHS Trust, NIHR Leeds Musculoskeletal Biomed Res Unit, Leeds Inst Rheumat & Musculoskeletal Med, Leeds, W Yorkshire, England
基金
日本学术振兴会;
关键词
rheumatoid arthritis; ultrasound; magnetic resonance imaging; POWER DOPPLER ULTRASONOGRAPHY; DYNAMIC MAGNETIC-RESONANCE; CLINICAL REMISSION; METACARPOPHALANGEAL JOINTS; KNEE SYNOVITIS; COHORTS; CONTRAST; CLASSIFICATION; INFLAMMATION; PREDICTION;
D O I
10.1093/rheumatology/kex036
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective. To evaluate diagnostic test accuracy of US compared with MRI for the detection of synovitis in RA patients. Methods. A systematic literature search was performed in the PubMed, EMBASE, Cochrane Library and Web of Science Core Collection databases. Studies evaluating the diagnostic test accuracy of US for synovitis detected by MRI as the reference standard for wrist, MCP, PIP and knee joints were included. To assess the overall accuracy, we calculated the diagnostic odds ratio using a DerSimonian-Laird random effects model and the area under the curve (AUC) for the hierarchical summary receiver operating characteristics using Holling's proportional hazards models. The summary estimate of the sensitivity and specificity were obtained using the bivariate model. Results. Fourteen of 601 identified articles were included in the review. The diagnostic odds ratio was 11.6 (95% CI 5.6, 24; I-2 = 0%), 28 (95% CI 12, 66; I-2 = 11%), 23 (95% CI 6.5, 84; I-2 = 19%) and 5.3 (95% CI 0.60, 48; I-2 = 0%) and the AUC was 0.81, 0.91, 0.91 and 0.61 for wrist, MCP, PIP and knee joints, respectively. The summary estimates of sensitivity and specificity were 0.73 (95% CI 0.51, 0.87)/0.78 (95% CI 0.46, 0.94), 0.64 (95% CI 0.43, 0.81)/0.93 (95% CI 0.88, 0.97), 0.71 (95% CI 0.33, 0.93)/0.94 (95% CI 0.89, 0.97) and 0.91 (95% CI 0.56, 0.99)/0.60 (95% CI 0.20, 0.90) for wrist, MCP, PIP and knee joints, respectively. Conclusion. US is a valid and reproducible technique for detecting synovitis in the wrist and finger joints. It may be considered for routine use as part of the standard diagnostic tools in RA.
引用
收藏
页码:49 / 58
页数:10
相关论文
共 50 条
  • [21] Baricitinib for Rheumatoid Arthritis: A Systematic Review and Meta-Analysis
    Zamora, Natalia V.
    Tayar, Jean
    Lopez-Olivo, Maria A.
    Christensen, Robin
    Suarez-Almazor, Maria
    ARTHRITIS & RHEUMATOLOGY, 2016, 68
  • [22] BARICITINIB FOR RHEUMATOID ARTHRITIS: A SYSTEMATIC REVIEW AND META-ANALYSIS
    Zamora, N. V.
    Tayar, J.
    Lopez-Olivo, M. A.
    Christensen, R.
    Suarez-Almazor, M. E.
    ANNALS OF THE RHEUMATIC DISEASES, 2016, 75 : 731 - 732
  • [23] Tofacitinib For Rheumatoid Arthritis: A Systematic Review and Meta-Analysis
    Lopez-Olivo, Maria A.
    Suarez-Almazor, Maria E.
    Bavineni, Mahesh
    ARTHRITIS AND RHEUMATISM, 2013, 65 : S625 - S625
  • [24] Diagnostic accuracy of point-of-care ultrasound for shock: a systematic review and meta-analysis
    Yoshida, Takuo
    Yoshida, Takuya
    Noma, Hisashi
    Nomura, Takeshi
    Suzuki, Akihiro
    Mihara, Takahiro
    CRITICAL CARE, 2023, 27 (01)
  • [25] Diagnostic accuracy of abdominal ultrasound for diagnosis of acute appendicitis: systematic review and meta-analysis
    Le Conte, P.
    ANNALES FRANCAISES DE MEDECINE D URGENCE, 2018, 8 (03): : 207 - 208
  • [26] Diagnostic accuracy of ultrasound in the diagnosis of Placenta accreta spectrum: systematic review and meta-analysis
    Ahmed M. Maged
    Akmal El-Mazny
    Nada Kamal
    Safaa I. Mahmoud
    Mona Fouad
    Noura El-Nassery
    Amal Kotb
    Wael S. Ragab
    Asmaa I. Ogila
    Ahmed A. Metwally
    Yossra Lasheen
    Radwa M. Fahmy
    Maha Katta
    Eman K. Shaeer
    Noha Salah
    BMC Pregnancy and Childbirth, 23
  • [27] Accuracy of Diagnostic Ultrasound in Patients With Suspected Subacromial Disorders: A Systematic Review and Meta-Analysis
    Ottenheijm, Ramon P.
    Jansen, Mariette J.
    Staal, J. Bart
    van den Bruel, Ann
    Weijers, Rene E.
    de Bie, Rob A.
    Dinant, Geert-Jan
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2010, 91 (10): : 1616 - 1625
  • [28] Diagnostic accuracy of ultrasound for upper extremity fractures in children: A systematic review and meta-analysis*
    Tsou, Po-Yang
    Ma, Yu-Kun
    Wang, Yu-Hsun
    Gillon, Jason T.
    Rafael, John
    Deanehan, Julia K.
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2021, 44 : 383 - 394
  • [29] Diagnostic accuracy of multiparametric ultrasound in the diagnosis of prostate cancer: systematic review and meta-analysis
    Tang, Yun
    Li, Xingsheng
    Jiang, Qing
    Zhai, Lingyun
    INSIGHTS INTO IMAGING, 2023, 14 (01)
  • [30] Diagnostic accuracy of ultrasound in diagnosing acute appendicitis in pregnancy: a systematic review and meta-analysis
    Moghadam, Maryam Nakhaie
    Salarzaei, Morteza
    Shahraki, Zahra
    EMERGENCY RADIOLOGY, 2022, 29 (03) : 437 - 448