Measurement of CO2 by Wavelength Modulated Reinjection Off-Axis Integrated Cavity Output Spectroscopy at 2 μm

被引:11
|
作者
Yuan, Zihao [1 ,2 ,3 ]
Huang, Yinbo [1 ,3 ]
Lu, Xingji [1 ,3 ]
Huang, Jun [1 ,2 ,3 ]
Liu, Qiang [1 ,3 ]
Qi, Gang [1 ,2 ,3 ]
Cao, Zhensong [1 ,2 ,3 ]
机构
[1] Chinese Acad Sci, Anhui Inst Opt & Fine Mech, HFIPS, Key Lab Atmospher Opt, Hefei 230031, Peoples R China
[2] Univ Sci & Technol China, Grad Sch, Sci Isl Branch, Hefei 230026, Peoples R China
[3] Adv Laser Technol Lab Anhui Prov, Hefei 230037, Peoples R China
关键词
off-axis integrated cavity output spectroscopy; reinjection; wavelength modulation spectroscopy; CO2; detection; ENHANCEMENT;
D O I
10.3390/atmos12101247
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A high sensitivity wavelength modulated reinjection off-axis integrated cavity output spectroscopy (WM-RE-OA-ICOS) experimental setup was built at a 2 mu m band. On the basis of an off-axis integrated output spectroscopy (OA-ICOS), combined with an optical reinjection (RE) approach to improve signal intensity, and wavelength modulation spectroscopy (WMS) to improve the signal-to-noise ratio (SNR) of the system, the experimental study of trace CO2 with high sensitivity was carried out using the setup. The performance was compared and evaluated, and the results show that: Compared with the OA-ICOS, the wavelength modulated reinjection OA-ICOS enhanced the signal intensity by 6.3 times, and the SNR increased 7.2 times from 179 to 1288. The Allan variance results showed that the detection limit of the system is 0.35 ppm when the average system time is 230 s. The setup was used to measure the indoor CO2 concentration for a long time (22 h), and the measured results were in line with the actual concentration change. The proposed method shows good performance enhancement for the OA-ICOS system in trace gas measurements.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Design considerations in high-sensitivity off-axis integrated cavity output spectroscopy
    E.J. Moyer
    D.S. Sayres
    G.S. Engel
    J.M. St. Clair
    F.N. Keutsch
    N.T. Allen
    J.H. Kroll
    J.G. Anderson
    Applied Physics B, 2008, 92
  • [32] Off-axis integrated cavity output spectroscopy for real-time methane measurements with an integrated wavelength-tunable light source
    He, Qixin
    Zheng, Chuantao
    Zheng, Kaiyuan
    Tittel, Frank K.
    INFRARED PHYSICS & TECHNOLOGY, 2021, 115
  • [33] Measurement of Carbon Isotopes in Methane Based on Off-Axis Integrated Cavity Output Spectroscopy Technology with Booster Optical Amplifier
    Yu Runqing
    Xia Hua
    Sun Pengshuai
    Pang Tao
    Wu Bian
    Zhang Zhirong
    ACTA OPTICA SINICA, 2024, 44 (05)
  • [34] Extremely sensitive detection of NO2 employing off-axis integrated cavity output spectroscopy coupled with multiple-line integrated absorption spectroscopy
    Rao, Gottipaty N.
    Karpf, Andreas
    APPLIED OPTICS, 2011, 50 (13) : 1915 - 1924
  • [35] Detection of Methane Hydrate in Deep Sea Based on Off-Axis Integrated Cavity Output Spectroscopy
    Dong Yang
    Wang Jingjing
    Zhou Xinyu
    Zhu Gongdong
    Qu Kang
    Wu Xiang'en
    Lu Wanjun
    Wen Mingming
    Tan Tu
    Liu Kun
    Gao Xiaoming
    CHINESE JOURNAL OF LASERS-ZHONGGUO JIGUANG, 2020, 47 (08):
  • [36] Optical re-injection in Off-Axis Integrated Cavity Output Spectroscopy, modelling and experiments
    Nadeem, Faisal
    Mandon, Julien
    Cristescu, Simona M.
    Harren, Frans J. M.
    2018 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2018,
  • [37] Detection of formaldehyde using off-axis integrated cavity output spectroscopy with an interband cascade laser
    Miller, J. H.
    Bakhirkin, Y. A.
    Ajtai, T.
    Tittel, F. K.
    Hill, C. J.
    Yang, R. Q.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2006, 85 (2-3): : 391 - 396
  • [38] Detection of formaldehyde using off-axis integrated cavity output spectroscopy with an interband cascade laser
    J.H. Miller
    Y.A. Bakhirkin
    T. Ajtai
    F.K. Tittel
    C.J. Hill
    R.Q. Yang
    Applied Physics B, 2006, 85 : 391 - 396
  • [39] Water vapor δ2H and δ18O measurements using off-axis integrated cavity output spectroscopy
    Sturm, P.
    Knohl, A.
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2010, 3 (01) : 67 - 77
  • [40] H2S Trace Detection using Off-Axis Integrated Cavity Output Spectroscopy in the Near-Infrared
    Chen, Weidong
    Kosterev, Anatoliy A.
    Tittel, Frank K.
    2007 CONFERENCE ON LASERS & ELECTRO-OPTICS/QUANTUM ELECTRONICS AND LASER SCIENCE CONFERENCE (CLEO/QELS 2007), VOLS 1-5, 2007, : 2572 - +