Design considerations in high-sensitivity off-axis integrated cavity output spectroscopy

被引:1
|
作者
E.J. Moyer
D.S. Sayres
G.S. Engel
J.M. St. Clair
F.N. Keutsch
N.T. Allen
J.H. Kroll
J.G. Anderson
机构
[1] University of Chicago,Dept. of the Geophysical Sciences
[2] Harvard University,Dept. of Chemistry and Chemical Biology
[3] University of Chicago,Dept. of Chemistry
[4] California Institute of Technology,Dept. of Geological and Planetary Sciences
[5] University of Wisconsin-Madison,Dept. of Chemistry
[6] Aerodyne Research,undefined
来源
Applied Physics B | 2008年 / 92卷
关键词
Optical Cavity; Quantum Cascade Laser; Electronic Noise; Minimum Detectable Absorption; Tunable Diode Laser Absorption Spectroscopy;
D O I
暂无
中图分类号
学科分类号
摘要
Off-axis integrated cavity output spectroscopy (OA-ICOS) has generated much interest because it potentially allows highly sensitive field measurements with robust optical alignment. We discuss here design choices involved in design of an OA-ICOS instrument and how these choices impact instrument sensitivity, using as our example the design of the Harvard ICOS isotope instrument, which demonstrates the highest reported sensitivity for mid-IR OA-ICOS (2.4×10-11 cm-1Hz-1/2 at 6.7 μm, obtained during measurements of water vapor isotopologues H2O, HDO, and H2  18O in the laboratory and onboard NASA’s WB-57 high-altitude research aircraft). We compare the sensitivity of several OA-ICOS instruments with differing design parameters, show how comparisons are hindered by differing definitions of instrument performance metrics, and suggest a common metric of MDAmeas, the fractional absorption equivalent to 1σ uncertainty in an actual measurement, normalized to 1 s integration. We also note that despite an emphasis on sensitivity in the literature, in the Harvard ICOS isotope instrument and likely also similar instruments, systematic errors associated with fitting of the baseline laser power are of equal importance to total measurement uncertainty.
引用
收藏
相关论文
共 50 条
  • [1] Design considerations in high-sensitivity off-axis integrated cavity output spectroscopy
    Moyer, E. J.
    Sayres, D. S.
    Engel, G. S.
    St. Clair, Jason M.
    Keutsch, F. N.
    Allen, N. T.
    Kroll, J. H.
    Anderson, J. G.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2008, 92 (03): : 467 - 474
  • [2] Sensitivity enhancement in off-axis integrated cavity output spectroscopy
    Centeno, R.
    Mandon, J.
    Cristescu, S. M.
    Harren, F. J. M.
    OPTICS EXPRESS, 2014, 22 (23): : 27985 - 27991
  • [3] High-sensitivity off-axis integrated cavity output spectroscopy implementing wavelength modulation and white noise perturbation
    Wang, Jingjing
    Tian, Xing
    Dong, Yang
    Chen, Jiajin
    Tan, Tu
    Zhu, Gongdong
    Chen, Weidong
    Gao, Xiaoming
    OPTICS LETTERS, 2019, 44 (13) : 3298 - 3301
  • [4] Wavelength Modulation Off-axis Integrated Cavity Output Spectroscopy for High-sensitivity Detection of OH Radicals in Mid-infrared
    Yang Nana
    Fang Bo
    Wang Chunhui
    Zhou Hao
    Wei Nana
    Zhao Weixiong
    Zhang Weijun
    ACTA PHOTONICA SINICA, 2023, 52 (03)
  • [5] Intensity enhancement in off-axis integrated cavity output spectroscopy
    Nadeem, Faisal
    Mandon, Julien
    Cristescu, Simona M.
    Harren, Frans J. M.
    APPLIED OPTICS, 2018, 57 (29) : 8536 - 8542
  • [6] Off-axis integrated cavity output spectroscopy and its application
    Tan, Zhongqi
    Long, Xingwu
    OPTICS COMMUNICATIONS, 2010, 283 (07) : 1406 - 1409
  • [7] High sensitivity detection of NO2 employing off-axis integrated cavity output spectroscopy coupled with multiple line integrated spectroscopy
    Rao, Gottipaty N.
    Karpf, Andreas
    ADVANCED ENVIRONMENTAL, CHEMICAL, AND BIOLOGICAL SENSING TECHNOLOGIES VIII, 2011, 8024
  • [8] Recent advances and applications of off-axis integrated cavity output spectroscopy
    Shao, Ligang
    Mei, Jiaoxu
    Chen, Jiajin
    Tan, Tu
    Wang, Guishi
    Liu, Kun
    Gao, Xiaoming
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2023, 65 (05) : 1489 - 1505
  • [9] Wavelength modulated off-axis integrated cavity output spectroscopy in the near infrared
    W. Zhao
    X. Gao
    W. Chen
    W. Zhang
    T. Huang
    T. Wu
    H. Cha
    Applied Physics B, 2007, 86 : 353 - 359
  • [10] Wavelength modulated off-axis integrated cavity output spectroscopy in the near infrared
    Zhao, W.
    Gao, X.
    Chen, W.
    Zhang, W.
    Huang, T.
    Wu, T.
    Cha, H.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2007, 86 (02): : 353 - 359