Intensity enhancement in off-axis integrated cavity output spectroscopy

被引:14
|
作者
Nadeem, Faisal [1 ]
Mandon, Julien [1 ]
Cristescu, Simona M. [1 ]
Harren, Frans J. M. [1 ]
机构
[1] Radboud Univ Nijmegen, Inst Mol & Mat, Mol & Laser Phys, Trace Gas Res Grp, Nijmegen, Netherlands
关键词
RING-DOWN SPECTROSCOPY; BREATH ANALYSIS; ABSORPTION; LASER; SPECTROMETER; PATHS; CELLS;
D O I
10.1364/AO.57.008536
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In the field of laser-based absorption spectroscopy, off-axis integrated cavity output spectroscopy is considered to be a sensitive and robust method, employing a simple optical design. However, one of the major drawbacks of non-mode-matched cavities combined with highly reflective mirrors (>99.98%) is its low output intensity. Here, we systematically investigate the increase in cavity output intensity, using a third re-injection mirror before the absorption cavity. The presented design not only enables high transmission power but also retains a long effective path length. To investigate the intensity enhancement, we used a CO(2 )absorption line in the near-IR wavelength region at 6240.10 cm(-1). In agreement with our simulation model, we achieved an intensity enhancement factor of 38. We achieved a noise equivalent absorption sensitivity to 1.6 x 10(-8) cm(-1) Hz(-1/2), which is no longer limited by the detectivity of the detector. (C) 2018 Optical Society of America
引用
收藏
页码:8536 / 8542
页数:7
相关论文
共 50 条
  • [1] Sensitivity enhancement in off-axis integrated cavity output spectroscopy
    Centeno, R.
    Mandon, J.
    Cristescu, S. M.
    Harren, F. J. M.
    OPTICS EXPRESS, 2014, 22 (23): : 27985 - 27991
  • [2] Off-axis integrated cavity output spectroscopy and its application
    Tan, Zhongqi
    Long, Xingwu
    OPTICS COMMUNICATIONS, 2010, 283 (07) : 1406 - 1409
  • [3] Recent advances and applications of off-axis integrated cavity output spectroscopy
    Shao, Ligang
    Mei, Jiaoxu
    Chen, Jiajin
    Tan, Tu
    Wang, Guishi
    Liu, Kun
    Gao, Xiaoming
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2023, 65 (05) : 1489 - 1505
  • [4] Wavelength modulated off-axis integrated cavity output spectroscopy in the near infrared
    W. Zhao
    X. Gao
    W. Chen
    W. Zhang
    T. Huang
    T. Wu
    H. Cha
    Applied Physics B, 2007, 86 : 353 - 359
  • [5] Wavelength modulated off-axis integrated cavity output spectroscopy in the near infrared
    Zhao, W.
    Gao, X.
    Chen, W.
    Zhang, W.
    Huang, T.
    Wu, T.
    Cha, H.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2007, 86 (02): : 353 - 359
  • [6] Denoising Technique in Gas Sensing Based on Off-Axis Integrated Cavity Output Spectroscopy
    Zhang Haipeng
    Zheng Kaiyuan
    Li Junhao
    Liu Zidi
    Li Xiuying
    Zheng Chuantao
    Wang Yiding
    ACTA OPTICA SINICA, 2021, 41 (24)
  • [7] Design considerations in high-sensitivity off-axis integrated cavity output spectroscopy
    Moyer, E. J.
    Sayres, D. S.
    Engel, G. S.
    St. Clair, Jason M.
    Keutsch, F. N.
    Allen, N. T.
    Kroll, J. H.
    Anderson, J. G.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2008, 92 (03): : 467 - 474
  • [8] OPO Based Off-Axis Integrated Cavity Output Spectroscopy for Rapid Chemical Sensing
    Arslanov, D. D.
    Harren, F. J. M.
    Lindsay, I. D.
    Boller, K. J.
    2010 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO) AND QUANTUM ELECTRONICS AND LASER SCIENCE CONFERENCE (QELS), 2010,
  • [9] Optimum signal-to-noise ratio in off-axis integrated cavity output spectroscopy
    Dyroff, Christoph
    OPTICS LETTERS, 2011, 36 (07) : 1110 - 1112
  • [10] Design considerations in high-sensitivity off-axis integrated cavity output spectroscopy
    E.J. Moyer
    D.S. Sayres
    G.S. Engel
    J.M. St. Clair
    F.N. Keutsch
    N.T. Allen
    J.H. Kroll
    J.G. Anderson
    Applied Physics B, 2008, 92