Semi-active control of walking-induced vibrations in bridges using adaptive tuned mass damper considering human-structure-interaction

被引:98
|
作者
Wang, Liangkun [1 ,2 ]
Nagarajaiah, Satish [2 ,3 ]
Shi, Weixing [1 ]
Zhou, Ying [1 ,4 ]
机构
[1] Tongji Univ, Dept Disaster Mitigat Struct, Shanghai 200092, Peoples R China
[2] Rice Univ, Dept Civil & Environm Engn, Houston, TX 77005 USA
[3] Rice Univ, Dept Mech Engn & Mat Sci, Houston, TX 77005 USA
[4] Tongji Univ, State Key Lab Disaster Reduct Civil Engn, Shanghai 200092, Peoples R China
基金
中国国家自然科学基金;
关键词
Serviceability problem; Human-structure interaction; Tuned mass damper; Variable mass; Adaptive control; Stochastic walking-induced vibrations; VERTICAL VIBRATIONS; MULTIPLE PEDESTRIANS; DYNAMIC INTERACTION; STIFFNESS; FRAMEWORK; MODEL; FOOTBRIDGE; EXCITATION; IDENTIFICATION; FORMULATION;
D O I
10.1016/j.engstruct.2021.112743
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Tuned mass dampers (TMDs) are used to control pedestrian induced vibrations of pedestrian bridges as traditional vibration control devices. A TMD can have a good control effect when it is tuned to the natural/vibrational frequency of the primary system. However, a traditional passive TMD is sensitive to the frequency deviation. Actual human-induced excitations can cover a wide frequency range and are stochastic virtually, which will cause a decrement in its control effect. The human-structure interaction (HSI) can also change the structural characteristic and lead to a mistuned TMD. To propose a more robust and effective TMD in solving the serviceability problem, a semi-active independent variable mass TMD (SAIVM-TMD) is introduced in this study. Wavelet transform (WT) is used to identify the structural instantaneous frequency, then, the mass of SAIVM-TMD is adjusted according to the WT - based control algorithm by actuating devices in real time. To highlight the control effect of SAIVM-TMD, a simply supported pedestrian bridge is carried out as a case study. The bridge is simplified to a Euler-Bernoulli beam according to an in-situ test and model analysis. Then, its dynamic responses under different controllers are analyzed and compared under single pedestrian periodic and stochastic walking-induced excitations. HSI is considered and a pedestrian is modulated as a moving spring-mass-damper (SMD) model. Then, a case under crowd-induced stochastic excitation is proposed. A passive TMD optimized for a pedestrian bridge under moving loads is used for comparison. Results show that SAIVM-TMD always has the best performance because it can adapt to the structural vibrational frequency changes efficiently and retune.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Adaptive semi-active vibration isolation considering uncertainties of MR damper and suspension structure
    Mori, Tomoaki
    Nilkhamhang, Itthisek
    Sano, Akira
    PROCEEDINGS OF THE 46TH IEEE CONFERENCE ON DECISION AND CONTROL, VOLS 1-14, 2007, : 5921 - +
  • [22] Semi-active control of seismic response of a building using MR fluid-based tuned mass damper
    Esteki, Kambiz
    Bagchi, Ashutosh
    Sedaghti, Ramin
    SMART STRUCTURES AND SYSTEMS, 2015, 16 (05) : 807 - 833
  • [23] Comparison of semi-active and passive tuned mass damper systems for vibration control of a wind turbine
    Lalonde, Eric R.
    Dai, Kaoshan
    Bitsuamlak, Girma
    Lu, Wensheng
    Zhao, Zhi
    WIND AND STRUCTURES, 2020, 30 (06) : 663 - 678
  • [24] Study on vibration control of rotor with semi-active cage-type tuned mass damper
    Huang, Xiu-Jin
    He, Li-Dong
    Huang, Wen-Chao
    Hangkong Dongli Xuebao/Journal of Aerospace Power, 2015, 30 (12): : 2882 - 2887
  • [25] Structural control of a grandstand using a semi-active pressurized tuned liquid column damper considering effects of passive crowds
    Riascos, Carlos
    Marulanda, Johannio
    Thomson, Peter
    STRUCTURAL CONTROL & HEALTH MONITORING, 2019, 26 (10):
  • [26] Study on Adaptive-Passive and Semi-Active Eddy Current Tuned Mass Damper with Variable Damping
    Shi, Weixing
    Wang, Liangkun
    Lu, Zheng
    Gao, Hui
    SUSTAINABILITY, 2018, 10 (01)
  • [27] Seismic structural control using semi-active tuned mass dampers
    杨润林
    周锡元
    刘锡荟
    EarthquakeEngineeringandEngineeringVibration, 2002, 1 (01) : 111 - 118
  • [28] Floor vibration control using semi-active tuned mass dampers
    Setareh, M
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2002, 29 (01) : 76 - 84
  • [29] Seismic structural control using semi-active tuned mass dampers
    Yang R.
    Zhou X.
    Liu X.
    Earthquake Engineering and Engineering Vibration, 2002, 1 (01) : 111 - 118
  • [30] Vibration control of midrise buildings by semi-active tuned mass damper including multi-layered soil-pile-structure-interaction
    Ghorbanzadeh, Mohammad
    Sensoy, Serhan
    Uygar, Eris
    STRUCTURES, 2022, 43 : 896 - 909