Dosimetric methods for and influence of exposure parameters on the establishment of reference doses in mammography

被引:4
|
作者
Zoetelief, J
Fitzgerald, M
Leitz, W
Säbel, M
机构
[1] TNO, Ctr Radiol Protect & Dosimetry, NL-2280 HV Rijswijk, Netherlands
[2] Univ London St Georges Hosp, Radiol Protect Ctr, London SW17 0QT, England
[3] Statens Stralskyddinst, S-17116 Stockholm, Sweden
[4] Univ Erlangen Nurnberg, Klin Frauenheilkunde, D-91054 Erlangen, Germany
关键词
D O I
10.1093/oxfordjournals.rpd.a032499
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
For the establishment of reference doses in mammography it is important to apply a dosimetric model relevant for risk assessment. Differences in dosimetric methods applied in mammography are related to the dosemeters used, e.g. thermoluminescent detectors and ionisation chambers, and the dosimetric quantities determined. i.e. entrance surface air kerma, entrance surface dose or average glandular dose. The exposure parameters influencing absorbed dose due to mammography include the X ray tube assembly, i.e. anode material, filtration and tube voltage; the exposure conditions, e.g. antiscatter grid, automatic exposure control and magnification; and characteristics of the film-screen combination including film processing and film density. The female breasts examined can be represented, on average, by a phantom or by a representative sample of patients. Reference values established in various protocols for entrance surface air kerma, entrance surface dose and average glandular dose are presented and discussed.
引用
收藏
页码:175 / 180
页数:6
相关论文
共 50 条
  • [1] Dosimetric methods for and influence of exposure parameters on the establishment of reference doses for examinations using fluoroscopy
    Gfirtner, H
    Giesse, E
    Schmidt, T
    RADIATION PROTECTION DOSIMETRY, 1998, 80 (1-3) : 121 - 128
  • [2] Computed tomography: Influence of exposure parameters and the establishment of reference dose values
    Kalender, WA
    RADIATION PROTECTION DOSIMETRY, 1998, 80 (1-3) : 163 - 166
  • [3] Dosimetric methods for the establishment of reference dose levels in conventional and computed radiography
    Mini, RL
    RADIATION PROTECTION DOSIMETRY, 1998, 80 (1-3) : 221 - 224
  • [4] Review of dosimetric methods for mammography in the UK Breast Screening Programme
    Young, KC
    Ramsdale, ML
    Bignell, F
    RADIATION PROTECTION DOSIMETRY, 1998, 80 (1-3) : 183 - 186
  • [5] Uncertainty in dosimetric methods outside the reference conditions
    Knöös, T.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S14 - S14
  • [6] Establishment of reference doses for examinations using digital fluoroscopy
    Faulkner, K
    Marshall, NW
    Lecomber, AR
    Kotre, CJ
    RADIATION PROTECTION DOSIMETRY, 1998, 80 (1-3) : 129 - 134
  • [7] PEDIATRIC HEAD CT EXPOSURE DOSES IN TUNISIA: A PILOT STUDY TOWARDS THE ESTABLISHMENT OF NATIONAL DIAGNOSTIC REFERENCE LEVELS
    Bouaoun, Abir
    Ben Omrane, Latifa
    Mogaadi, Mohamed
    Khomsi, Wiem Douira
    Zidi, Asma
    Hammou, Azza
    RADIATION PROTECTION DOSIMETRY, 2018, 182 (02) : 241 - 251
  • [8] The establishment of reference doses in paediatric radiology as a function of patient size
    Hart, D
    Wall, BF
    Shrimpton, PC
    Dance, DR
    RADIATION PROTECTION DOSIMETRY, 2000, 90 (1-2) : 235 - 238
  • [9] Measurement of some dosimetric parameters for two mammography systems using thermoluminescent dosimetry
    Camargo-Mendoza, Raul E.
    Poletti, Martin E.
    Costa, Alessandro M.
    Caldas, Linda V. E.
    RADIATION MEASUREMENTS, 2011, 46 (12) : 2086 - 2089
  • [10] Optimization of exposure parameters in full field digital mammography
    Williams, Mark B.
    Raghunathan, Priya
    More, Mitali J.
    Seibert, J. Anthony
    Kwan, Alexander
    Lo, Joseph Y.
    Samei, Ehsan
    Ranger, Nicole T.
    Fajardo, Laurie L.
    McGruder, Allen
    McGruder, Sandra M.
    Maidment, Andrew D. A.
    Yaffe, Martin J.
    Bloomquist, Aili
    Mawdsley, Gordon E.
    MEDICAL PHYSICS, 2008, 35 (06) : 2414 - 2423