Computed tomography: Influence of exposure parameters and the establishment of reference dose values

被引:5
|
作者
Kalender, WA [1 ]
机构
[1] Univ Erlangen Nurnberg, Inst Med Phys, D-91054 Erlangen, Germany
关键词
D O I
10.1093/oxfordjournals.rpd.a032496
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The frequency and importance of CT in radiological diagnosis is still increasing; the concomitant increase in the radiation exposure of the population is a point of growing concern. Further efforts are demanded to determine patient dose values and their dependence on exposure factors, to establish demands on image quality and to provide the demanded level of image quality with minimal dose. The respective efforts and the underlying basic principles and considerations are reviewed. The influence of components, of scan types and parameters is briefly explained. A particular focus is on new technical approaches to reduce dose in CT. These include adequate use of spiral CT and anatomically adapted tube current modulation. It appears possible to reduce dose in CT through technical means by a factor of two in many cases without a loss in image quality. An automatic exposure control (AEC) for CT must be an aim for future CT developments to ensure that this goal will be achieved or even exceeded, based on technical advances and on the definition of quality criteria.
引用
收藏
页码:163 / 166
页数:4
相关论文
共 50 条
  • [1] Influence of exposure parameters on patient dose and image noise in computed tomography
    Stoyanov, Desislav
    Vassileva, Jenia
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2009, 15 (04): : 215 - 226
  • [2] Establishment of diagnostic reference levels in low-dose renal computed tomography
    Rawashdeh, Mohammad
    Saade, Charbel
    ACTA RADIOLOGICA, 2023, 64 (02) : 829 - 836
  • [3] Techniques and parameters for estimating radiation exposure and dose in cardiac computed tomography
    Gerber, TC
    Kuzo, RS
    Morin, RL
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2005, 21 (01): : 165 - 176
  • [4] PATIENT GROUPING FOR DOSE SURVEYS AND ESTABLISHMENT OF DIAGNOSTIC REFERENCE LEVELS IN PAEDIATRIC COMPUTED TOMOGRAPHY
    Vassileva, J.
    Rehani, M.
    RADIATION PROTECTION DOSIMETRY, 2015, 165 (1-4) : 81 - 85
  • [5] Towards establishment of the national reference dose levels from computed tomography examinations in Tanzania
    Ngaile, JE
    Msaki, P
    Kazema, R
    JOURNAL OF RADIOLOGICAL PROTECTION, 2006, 26 (02) : 213 - 225
  • [6] Techniques and parameters for estimating radiation exposure and dose in cardiac computed tomography
    Thomas C. Gerber
    Ronald S. Kuzo
    Richard L. Morin
    The International Journal of Cardiovascular Imaging, 2005, 21 : 165 - 176
  • [7] Dosimetric methods for and influence of exposure parameters on the establishment of reference doses in mammography
    Zoetelief, J
    Fitzgerald, M
    Leitz, W
    Säbel, M
    RADIATION PROTECTION DOSIMETRY, 1998, 80 (1-3) : 175 - 180
  • [8] Establishment of institutional diagnostic reference level for Computed Tomography dose on 160 slicer Computed Tomography scan at Lady Reading Hospital Peshawar
    Khan, Muhammad Imran
    Khan, Muhammad Zeeshan
    Afzal, Fariha
    Zenab
    Khan, Shandana
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2023, 73 (04) : 808 - 811
  • [9] Establishment of national diagnostic dose reference levels (DRLs) for routine computed tomography examinations in Jordan
    Radaideh, Khaldoon
    Al-Radaideh, Ali
    Ramli, Ramzun Maizan
    Saleh, Abdallah
    Alshayeb, Rasha
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2023, 29 (01): : 26 - 34
  • [10] Establishment of diagnostic reference levels in cardiac computed tomography
    Rawashdeh, Mohammad
    Saade, Charbel
    Zaitoun, Maha
    Abdelrahman, Mostafa
    Brennan, Patrick
    Alewaidat, Haytham
    McEntee, Mark F.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (10): : 181 - 186