Computed tomography: Influence of exposure parameters and the establishment of reference dose values

被引:5
|
作者
Kalender, WA [1 ]
机构
[1] Univ Erlangen Nurnberg, Inst Med Phys, D-91054 Erlangen, Germany
关键词
D O I
10.1093/oxfordjournals.rpd.a032496
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The frequency and importance of CT in radiological diagnosis is still increasing; the concomitant increase in the radiation exposure of the population is a point of growing concern. Further efforts are demanded to determine patient dose values and their dependence on exposure factors, to establish demands on image quality and to provide the demanded level of image quality with minimal dose. The respective efforts and the underlying basic principles and considerations are reviewed. The influence of components, of scan types and parameters is briefly explained. A particular focus is on new technical approaches to reduce dose in CT. These include adequate use of spiral CT and anatomically adapted tube current modulation. It appears possible to reduce dose in CT through technical means by a factor of two in many cases without a loss in image quality. An automatic exposure control (AEC) for CT must be an aim for future CT developments to ensure that this goal will be achieved or even exceeded, based on technical advances and on the definition of quality criteria.
引用
收藏
页码:163 / 166
页数:4
相关论文
共 50 条
  • [31] Establishment of diagnostic reference levels in computed tomography for select procedures in Pudhuchery, India
    Saravanakumar, A.
    Vaideki, K.
    Govindarajan, K. N.
    Jayakumar, S.
    JOURNAL OF MEDICAL PHYSICS, 2014, 39 (01) : 50 - 55
  • [32] Dose Reduction in Pediatric Computed Tomography with Automated Exposure Control
    Alibek, Sedat
    Brand, Martin
    Suess, Christoph
    Wuest, Wolfgang
    Uder, Michael
    Greess, Holger
    ACADEMIC RADIOLOGY, 2011, 18 (06) : 690 - 693
  • [33] Establishment of national diagnostic reference levels as guidelines for computed tomography radiation in Jordan
    Al Ewaidat, Haytham
    Balawi, Sara
    Bataineh, Ziad
    Al-Dwairi, Ahmed
    Al-Khalily, Majd
    Azez, Khalaf Abdel
    Almakhadmeh, Ali
    INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 2023, 33 (04) : 1223 - 1234
  • [34] Establishment of diagnostic reference levels in computed tomography in two large hospitals in Oman
    Bouchareb, Yassine
    Al-Maimani, Amal
    Al-Balushi, Al-Yaqin
    Al-Kalbani, Maather
    Al-Maskari, Hasina
    Al-Dhuhli, Humoud
    Al-Kindi, Faiza
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (17) : 2148 - 2155
  • [35] Influence of X-ray computed tomography (CT) exposure and reconstruction parameters on positron emission tomography (PET) quantitation
    Shon, Ivan Ho
    Reece, Christopher
    Hennessy, Thomas
    Horsfield, Megan
    McBride, Bruce
    EJNMMI PHYSICS, 2020, 7 (01)
  • [36] Influence of X-ray computed tomography (CT) exposure and reconstruction parameters on positron emission tomography (PET) quantitation
    Ivan Ho Shon
    Christopher Reece
    Thomas Hennessy
    Megan Horsfield
    Bruce McBride
    EJNMMI Physics, 7
  • [37] ESTABLISHMENT OF LABORATORY REFERENCE VALUES
    ELHAZMI, MAF
    SAUDI MEDICAL JOURNAL, 1991, 12 (03) : 167 - 171
  • [38] Establishment of diagnostic reference levels and estimation of effective dose from computed tomography head scans at a tertiary hospital in South Africa
    Nyathi M.
    Iranian Journal of Medical Physics, 2020, 17 (02) : 99 - 106
  • [39] Establishment of local diagnostic reference levels for computed tomography with cloud-based automated dose-tracking software in Turkiye
    Kahraman, Gokhan
    Haberal, Kemal Murat
    Agildere, Ahmet Muhtesem
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2024, 30 (03): : 205 - 211
  • [40] Development of a computational tool for estimating computed tomography dose parameters
    Almohiy, Hussain M.
    Hussein, Khalid, I
    Alqahtani, Mohammed S.
    Rawashdeh, Mohammad
    Elshiekh, Elhussaien
    Alshahrani, Madshush M.
    Saad, Mohammed
    Foley, Shane
    Saade, Charbel
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2020, 28 (06) : 1025 - 1035