Dosimetric methods for and influence of exposure parameters on the establishment of reference doses in mammography

被引:4
|
作者
Zoetelief, J
Fitzgerald, M
Leitz, W
Säbel, M
机构
[1] TNO, Ctr Radiol Protect & Dosimetry, NL-2280 HV Rijswijk, Netherlands
[2] Univ London St Georges Hosp, Radiol Protect Ctr, London SW17 0QT, England
[3] Statens Stralskyddinst, S-17116 Stockholm, Sweden
[4] Univ Erlangen Nurnberg, Klin Frauenheilkunde, D-91054 Erlangen, Germany
关键词
D O I
10.1093/oxfordjournals.rpd.a032499
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
For the establishment of reference doses in mammography it is important to apply a dosimetric model relevant for risk assessment. Differences in dosimetric methods applied in mammography are related to the dosemeters used, e.g. thermoluminescent detectors and ionisation chambers, and the dosimetric quantities determined. i.e. entrance surface air kerma, entrance surface dose or average glandular dose. The exposure parameters influencing absorbed dose due to mammography include the X ray tube assembly, i.e. anode material, filtration and tube voltage; the exposure conditions, e.g. antiscatter grid, automatic exposure control and magnification; and characteristics of the film-screen combination including film processing and film density. The female breasts examined can be represented, on average, by a phantom or by a representative sample of patients. Reference values established in various protocols for entrance surface air kerma, entrance surface dose and average glandular dose are presented and discussed.
引用
收藏
页码:175 / 180
页数:6
相关论文
共 50 条
  • [31] 239Pu[sbnd]Be neutron reference field: Physical and dosimetric parameters
    Nguyen, Ngoc-Quynh
    Hoang, Thanh-Phi-Hung
    Nguyen, Minh-Cong
    Dinh, Tien-Hung
    Cao, Van-Hiep
    Le, Ngoc-Thiem
    Radiation Physics and Chemistry, 2024, 217
  • [32] Evaluation of the effect of a quality control programme in mammography on technical and exposure parameters
    Milano, F
    Maggi, E
    del Turco, MR
    RADIATION PROTECTION DOSIMETRY, 2000, 90 (1-2) : 263 - 266
  • [33] Additive value of exposure parameters for breast cancer diagnosis in digital mammography
    Le Ma
    Xiaojia Lin
    Bingjia Lai
    Wenshang Wang
    Yuxing Cai
    Weiguo Chen
    Genggeng Qin
    European Radiology, 2021, 31 : 2539 - 2547
  • [34] Additive value of exposure parameters for breast cancer diagnosis in digital mammography
    Ma, Le
    Lin, Xiaojia
    Lai, Bingjia
    Wang, Wenshang
    Cai, Yuxing
    Chen, Weiguo
    Qin, Genggeng
    EUROPEAN RADIOLOGY, 2021, 31 (04) : 2539 - 2547
  • [35] QUALITY-CONTROL IN MAMMOGRAPHY BASED ON AUTOMATIC ACQUISITION OF EXPOSURE PARAMETERS
    WALDERHAUG, TP
    EINARSSON, G
    KRISTINSSON, S
    MAGNUSSON, SM
    SIGFUSSON, BF
    RADIATION PROTECTION DOSIMETRY, 1995, 57 (1-4) : 199 - 201
  • [36] REFERENCE NEUTRON FIELDS IN CALIBRATION LABORATORY; SIMPLE DOSIMETRIC PARAMETERS AND THEIR CHANGES IN TIME
    Domanski, S.
    Tulik, P.
    Boimski, B.
    RADIATION PROTECTION DOSIMETRY, 2018, 180 (1-4) : 33 - 36
  • [37] Exposure data for pharmacovigilance -: Methods and parameters
    Bahri, P.
    Begaud, B.
    Moore, N.
    DRUG SAFETY, 2006, 29 (10) : 948 - 948
  • [38] Survey of computed tomography doses and establishment of national diagnostic reference levels in the Republic of Belarus
    Kharuzhyk, S. A.
    Matskevich, S. A.
    Filjustin, A. E.
    Bogushevich, E. V.
    Ugolkova, S. A.
    RADIATION PROTECTION DOSIMETRY, 2010, 139 (1-3) : 367 - 370
  • [39] INFLUENCE OF ALTERING BIOLOGICAL PARAMETERS IN DETERMINATION OF INTERNAL DOSES
    PREDMERS.T
    FARKAS, G
    ACTA BIOCHIMICA ET BIOPHYSICA HUNGARICA, 1973, 8 (03) : 208 - 208
  • [40] Establishment of reference values for selected haematological parameters in young adult Nigerians
    Ayemoba, Ojor
    Hussain, Nurudeen
    Umar, Tahir
    Ajemba-Life, Anthony
    Kene, Terfa
    Edom, Uchechukwu
    Ogueri, Ikechukwu
    Nwagbara, Goodluck
    Ochai, Inalegwu
    Eneja, Chikwado
    PLOS ONE, 2019, 14 (04):